ITS - Intelligent Transportation Systems Report ITS Home Page

Appendix B: Test Cases and Results

Object Test Case TC-O-001
VDOT Implemented: Yes
Std Par Ref 5.2.1
OID 1.3.6.1.4.1.1206.4.2.3.1.1.0
Object Name dmsSignAccess
Syntax Access Status
INTEGER (0..255)read-onlyoptional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object4Success
2 - Set Object to Min. Value4Success
3 - Set Object to Max. Value4Success
4 - Attempt Write to Read-Only Object Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object Skipped - Not not-accessible
6 - Attempt to Set Value > Max. Skipped - not writable
7 - Attempt to Set Value < Min. Skipped - not writable
8 - Restore Object to Original Value Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-002
VDOT Implemented: Yes
Std Par Ref 5.2.2
OID 1.3.6.1.4.1.1206.4.2.3.1.2.0
Object Name dmsSignType
Syntax Access Status
INTEGER {enumeration}read-onlyoptional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 6 (vmsFull) Success
2 - Set Object to Min. Value 6 (vmsFull) Success
3 - Set Object to Max. Value 6 (vmsFull) Success
4 - Attempt Write to Read-Only Object   Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max.   Skipped - not writable
7 - Attempt to Set Value < Min.   Skipped - not writable
8 - Restore Object to Original Value   Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-003
VDOT Implemented: Yes
Std Par Ref 5.2.3
OID 1.3.6.1.4.1.1206.4.2.3.1.3.0
Object Name dmsSignHeight
Syntax Access Status
INTEGER (0..65535) read-only optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 1867 Success
2 - Set Object to Min. Value 1867 Success
3 - Set Object to Max. Value 1867 Success
4 - Attempt Write to Read-Only Object   Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max.   Skipped - not writable
7 - Attempt to Set Value < Min.   Skipped - not writable
8 - Restore Object to Original Value   Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-004
VDOT Implemented: Yes
Std Par Ref 5.2.4
OID 1.3.6.1.4.1.1206.4.2.3.1.4.0
Object Name dmsSignWidth
Syntax Access Status
INTEGER (0..65535) read-only optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 3562 Success
2 - Set Object to Min. Value 3562 Success
3 - Set Object to Max. Value 3562 Success
4 - Attempt Write to Read-Only Object   Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max.   Skipped - not writable
7 - Attempt to Set Value < Min.   Skipped - not writable
8 - Restore Object to Original Value   Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-005
VDOT Implemented: Yes
Std Par Ref 5.2.5
OID 1.3.6.1.4.1.1206.4.2.3.1.5.0
Object Name dmsHorizontalBorder
Syntax Access Status
INTEGER (0..65535) read-only optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 330 Success
2 - Set Object to Min. Value 330 Success
3 - Set Object to Max. Value 330 Success
4 - Attempt Write to Read-Only Object   Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max.   Skipped - not writable
7 - Attempt to Set Value < Min.   Skipped - not writable
8 - Restore Object to Original Value   Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-006
VDOT Implemented: Yes
Std Par Ref 5.2.6
OID 1.3.6.1.4.1.1206.4.2.3.1.6.0
Object Name dmsVerticalBorder
Syntax Access Status
INTEGER (0..65535) read-only optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 292 Success
2 - Set Object to Min. Value 292 Success
3 - Set Object to Max. Value 292 Success
4 - Attempt Write to Read-Only Object   Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max.   Skipped - not writable
7 - Attempt to Set Value < Min.   Skipped - not writable
8 - Restore Object to Original Value   Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-007
VDOT Implemented: Yes
Std Par Ref 5.2.7
OID 1.3.6.1.4.1.1206.4.2.3.1.7.0
Object Name dmsLegend
Syntax Access Status
INTEGER {enumeration} read-only optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 2 (noLegend) Success
2 - Set Object to Min. Value 2 (noLegend) Success
3 - Set Object to Max. Value 2 (noLegend) Success
4 - Attempt Write to Read-Only Object   Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max.   Skipped - not writable
7 - Attempt to Set Value < Min.   Skipped - not writable
8 - Restore Object to Original Value   Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-008
VDOT Implemented: Yes
Std Par Ref 5.2.8
OID 1.3.6.1.4.1.1206.4.2.3.1.8.0
Object Name dmsBeaconType
Syntax Access Status
INTEGER {enumeration} read-only optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 2 (none) Success
2 - Set Object to Min. Value 2 (none) Success
3 - Set Object to Max. Value 2 (none) Success
4 - Attempt Write to Read-Only Object   Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max.   Skipped - not writable
7 - Attempt to Set Value < Min.   Skipped - not writable
8 - Restore Object to Original Value   Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-009
VDOT Implemented: Yes
Std Par Ref 5.2.9
OID 1.3.6.1.4.1.1206.4.2.3.1.9.0
Object Name dmsSignTechnology
Syntax Access Status
INTEGER (0..65535) read-only optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 2 Success
2 - Set Object to Min. Value 2 Success
3 - Set Object to Max. Value 2 Success
4 - Attempt Write to Read-Only Object   Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max.   Skipped - not writable
7 - Attempt to Set Value < Min.   Skipped - not writable
8 - Restore Object to Original Value   Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-010
VDOT Implemented: Yes
Std Par Ref 5.3.1
OID 1.3.6.1.4.1.1206.4.2.3.2.1.0
Object Name vmsCharacterHeightPixels
Syntax Access Status
INTEGER (0..255) read-only optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 0 Success
2 - Set Object to Min. Value 0 Success
3 - Set Object to Max. Value 0 Success
4 - Attempt Write to Read-Only Object   Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max.   Skipped - not writable
7 - Attempt to Set Value < Min.   Skipped - not writable
8 - Restore Object to Original Value   Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-011
VDOT Implemented: Yes
Std Par Ref 5.3.2
OID 1.3.6.1.4.1.1206.4.2.3.2.2.0
Object Name vmsCharacterWidthPixels
Syntax Access Status
INTEGER (0..255) read-only optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 0 Success
2 - Set Object to Min. Value 0 Success
3 - Set Object to Max. Value 0 Success
4 - Attempt Write to Read-Only Object   Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max.   Skipped - not writable
7 - Attempt to Set Value < Min.   Skipped - not writable
8 - Restore Object to Original Value   Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-012
VDOT Implemented: Yes
Std Par Ref 5.3.3
OID 1.3.6.1.4.1.1206.4.2.3.2.3.0
Object Name vmsSignHeightPixels
Syntax Access Status
INTEGER (0..65535) read-only optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 27 Success
2 - Set Object to Min. Value 27 Success
3 - Set Object to Max. Value 27 Success
4 - Attempt Write to Read-Only Object   Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max.   Skipped - not writable
7 - Attempt to Set Value < Min.   Skipped - not writable
8 - Restore Object to Original Value   Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-013
VDOT Implemented: Yes
Std Par Ref 5.3.4
OID 1.3.6.1.4.1.1206.4.2.3.2.4.0
Object Name vmsSignWidthPixels
Syntax Access Status
INTEGER (0..65535) read-only optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 60 Success
2 - Set Object to Min. Value 60 Success
3 - Set Object to Max. Value 60 Success
4 - Attempt Write to Read-Only Object   Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max.   Skipped - not writable
7 - Attempt to Set Value < Min.   Skipped - not writable
8 - Restore Object to Original Value   Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-014
VDOT Implemented: Yes
Std Par Ref 5.3.5
OID 1.3.6.1.4.1.1206.4.2.3.2.5.0
Object Name vmsHorizontalPitch
Syntax Access Status
INTEGER (0..255) read-only optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 48 Success
2 - Set Object to Min. Value 48 Success
3 - Set Object to Max. Value 48 Success
4 - Attempt Write to Read-Only Object   Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max.   Skipped - not writable
7 - Attempt to Set Value < Min.   Skipped - not writable
8 - Restore Object to Original Value   Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-015
VDOT Implemented: Yes
Std Par Ref 5.3.6
OID 1.3.6.1.4.1.1206.4.2.3.2.6.0
Object Name vmsVerticalPitch
Syntax Access Status
INTEGER (0..255) read-only optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 48 Success
2 - Set Object to Min. Value 48 Success
3 - Set Object to Max. Value 48 Success
4 - Attempt Write to Read-Only Object   Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max.   Skipped - not writable
7 - Attempt to Set Value < Min.   Skipped - not writable
8 - Restore Object to Original Value   Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-016
VDOT Implemented: Yes
Std Par Ref 5.3.7
OID 1.3.6.1.4.1.1206.4.2.3.2.7.0
Object Name vmsMaxNumberPages
Syntax Access Status
INTEGER (1..255) read-only optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 3 Success
2 - Set Object to Min. Value 3 Success
3 - Set Object to Max. Value 3 Success
4 - Attempt Write to Read-Only Object   Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max.   Skipped - not writable
7 - Attempt to Set Value < Min.   Skipped - not writable
8 - Restore Object to Original Value   Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-017
VDOT Implemented: Yes
Std Par Ref 5.3.8
OID 1.3.6.1.4.1.1206.4.2.3.2.8.0
Object Name vmsMaxMultiStringLength
Syntax Access Status
INTEGER (0..65535) read-only optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 491 Success
2 - Set Object to Min. Value 491 Success
3 - Set Object to Max. Value 491 Success
4 - Attempt Write to Read-Only Object   Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max.   Skipped - not writable
7 - Attempt to Set Value < Min.   Skipped - not writable
8 - Restore Object to Original Value   Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-018
VDOT Implemented: Yes
Std Par Ref 5.4.1
OID 1.3.6.1.4.1.1206.4.2.3.3.1.0
Object Name numFonts
Syntax Access Status
INTEGER (0..255) read-only optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 4 Success
2 - Set Object to Min. Value 4 Success
3 - Set Object to Max. Value 4 Success
4 - Attempt Write to Read-Only Object   Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max.   Skipped - not writable
7 - Attempt to Set Value < Min.   Skipped - not writable
8 - Restore Object to Original Value   Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-019
VDOT Implemented: Yes
Std Par Ref 5.4.2.1
OID 1.3.6.1.4.1.1206.4.2.3.3.2.1.1.1
Object Name fontIndex
Syntax Access Status
INTEGER (1..255) read-only optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 1 Success
2 - Set Object to Min. Value 1 Success
3 - Set Object to Max. Value 1 Success
4 - Attempt Write to Read-Only Object   Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max.   Skipped - not writable
7 - Attempt to Set Value < Min.   Skipped - not writable
8 - Restore Object to Original Value   Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-020
VDOT Implemented: Yes
Std Par Ref 5.4.2.1
OID 1.3.6.1.4.1.1206.4.2.3.3.2.1.1.2
Object Name fontIndex
Syntax Access Status
INTEGER (1..255) read-only optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 2 Success
2 - Set Object to Min. Value 2 Success
3 - Set Object to Max. Value 2 Success
4 - Attempt Write to Read-Only Object   Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max.   Skipped - not writable
7 - Attempt to Set Value < Min.   Skipped - not writable
8 - Restore Object to Original Value   Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-021
VDOT Implemented: Yes
Std Par Ref 5.4.2.2
OID 1.3.6.1.4.1.1206.4.2.3.3.2.1.2.1
Object Name fontNumber
Syntax Access Status
INTEGER (1..255) read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 1 Success
2 - Set Object to Min. Value 1 Success
3 - Set Object to Max. Value 1 Success
4 - Attempt Write to Read-Only Object   Skipped - Not read only
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 256 Success - did not write greater than Max
7 - Attempt to Set Value < Min. 0 Success - did not write less than Min
8 - Restore Object to Original Value   Failed - GenErr

Overall Test Case Results: Passed

Object Test Case TC-O-022
VDOT Implemented: Yes
Std Par Ref 5.4.2.2
OID 1.3.6.1.4.1.1206.4.2.3.3.2.1.2.2
Object Name fontNumber
Syntax Access Status
INTEGER (1..255) read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 1 Success
2 - Set Object to Min. Value 1 Success
3 - Set Object to Max. Value 1 Success
4 - Attempt Write to Read-Only Object   Skipped - Not read only
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 256 Success - did not write greater than Max
7 - Attempt to Set Value < Min. 0 Success - did not write less than Min
8 - Restore Object to Original Value   Failed - GenErr

Overall Test Case Results: Passed

Object Test Case TC-O-023
VDOT Implemented: Yes
Std Par Ref 5.4.2.3
OID 1.3.6.1.4.1.1206.4.2.3.3.2.1.3.1
Object Name fontName
Syntax Access Status
DisplayString (SIZE (0..64)) read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object F0F5x7LM Success
2 - Set Object to Min. Value F0F5x7LM Success
3 - Set Object to Max. Value F0F5x7LM Success
4 - Attempt Write to Read-Only Object 00 Skipped - Not read only
5 - Attempt Read of Non-Accessible Object 00 Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 1 Success - did not write greater than Max
7 - Attempt to Set Value < Min. -1 Success - did not write less than Min
8 - Restore Object to Original Value 00 Failed - GenErr

Overall Test Case Results: Passed

Object Test Case TC-O-024
VDOT Implemented: Yes
Std Par Ref 5.4.2.3
OID 1.3.6.1.4.1.1206.4.2.3.3.2.1.3.2
Object Name fontName
Syntax Access Status
DisplayString (SIZE (0..64)) read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object   Success
2 - Set Object to Min. Value   Success
3 - Set Object to Max. Value   Success
4 - Attempt Write to Read-Only Object 00 Skipped - Not read only
5 - Attempt Read of Non-Accessible Object 00 Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 1 Success - did not write greater than Max
7 - Attempt to Set Value < Min. -1 Success - did not write less than Min
8 - Restore Object to Original Value 00 Failed - GenErr

Overall Test Case Results: Passed

Object Test Case TC-O-025
VDOT Implemented: Yes
Std Par Ref 5.4.2.4
OID 1.3.6.1.4.1.1206.4.2.3.3.2.1.4.1
Object Name fontHeight
Syntax Access Status
INTEGER (0..255) read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 7 Success
2 - Set Object to Min. Value 7 Success
3 - Set Object to Max. Value 7 Success
4 - Attempt Write to Read-Only Object   Skipped - Not read only
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 256 Success - did not write greater than Max
7 - Attempt to Set Value < Min. -1 Success - did not write less than Min
8 - Restore Object to Original Value   Failed - GenErr

Overall Test Case Results: Passed

Object Test Case TC-O-026
VDOT Implemented: Yes
Std Par Ref 5.4.2.4
OID 1.3.6.1.4.1.1206.4.2.3.3.2.1.4.2
Object Name fontHeight
Syntax Access Status
INTEGER (0..255) read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 0 Success
2 - Set Object to Min. Value 0 Success
3 - Set Object to Max. Value 0 Success
4 - Attempt Write to Read-Only Object   Skipped - Not read only
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 256 Success - did not write greater than Max
7 - Attempt to Set Value < Min. -1 Success - did not write less than Min
8 - Restore Object to Original Value   Failed - GenErr

Overall Test Case Results: Passed

Object Test Case TC-O-027
VDOT Implemented: Yes
Std Par Ref 5.4.2.5
OID 1.3.6.1.4.1.1206.4.2.3.3.2.1.5.1
Object Name fontCharSpacing
Syntax Access Status
INTEGER (0..255) read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 1 Success
2 - Set Object to Min. Value 1 Success
3 - Set Object to Max. Value 1 Success
4 - Attempt Write to Read-Only Object   Skipped - Not read only
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 256 Success - did not write greater than Max
7 - Attempt to Set Value < Min. -1 Success - did not write less than Min
8 - Restore Object to Original Value   Failed - GenErr

Overall Test Case Results: Passed

Object Test Case TC-O-028
VDOT Implemented: Yes
Std Par Ref 5.4.2.5
OID 1.3.6.1.4.1.1206.4.2.3.3.2.1.5.2
Object Name fontCharSpacing
Syntax Access Status
INTEGER (0..255) read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 0 Success
2 - Set Object to Min. Value 0 Success
3 - Set Object to Max. Value 0 Success
4 - Attempt Write to Read-Only Object   Skipped - Not read only
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 256 Success - did not write greater than Max
7 - Attempt to Set Value < Min. -1 Success - did not write less than Min
8 - Restore Object to Original Value   Failed - GenErr

Overall Test Case Results: Passed

Object Test Case TC-O-029
VDOT Implemented: Yes
Std Par Ref 5.4.2.6
OID 1.3.6.1.4.1.1206.4.2.3.3.2.1.6.1
Object Name fontLineSpacing
Syntax Access Status
INTEGER (0..255) read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 0 Success
2 - Set Object to Min. Value 0 Success
3 - Set Object to Max. Value 0 Success
4 - Attempt Write to Read-Only Object   Skipped - Not read only
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 256 Success - did not write greater than Max
7 - Attempt to Set Value < Min. -1 Success - did not write less than Min
8 - Restore Object to Original Value   Failed - GenErr

Overall Test Case Results: Passed

Object Test Case TC-O-030
VDOT Implemented: Yes
Std Par Ref 5.4.2.6
OID 1.3.6.1.4.1.1206.4.2.3.3.2.1.6.2
Object Name fontLineSpacing
Syntax Access Status
INTEGER (0..255) read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 0 Success
2 - Set Object to Min. Value 0 Success
3 - Set Object to Max. Value 0 Success
4 - Attempt Write to Read-Only Object   Skipped - Not read only
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 256 Success - did not write greater than Max
7 - Attempt to Set Value < Min. -1 Success - did not write less than Min
8 - Restore Object to Original Value   Failed - GenErr

Overall Test Case Results: Passed

Object Test Case TC-O-031
VDOT Implemented: Yes
Std Par Ref 5.4.2.7
OID 1.3.6.1.4.1.1206.4.2.3.3.2.1.7.1
Object Name fontVersionID
Syntax Access Status
INTEGER (0..65535) read-only optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 15516 Success
2 - Set Object to Min. Value 15516 Success
3 - Set Object to Max. Value 15516 Success
4 - Attempt Write to Read-Only Object   Failed - GenErr
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max.   Skipped - not writable
7 - Attempt to Set Value < Min.   Skipped - not writable
8 - Restore Object to Original Value   Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-032
VDOT Implemented: Yes
Std Par Ref 5.4.2.7
OID 1.3.6.1.4.1.1206.4.2.3.3.2.1.7.2
Object Name fontVersionID
Syntax Access Status
INTEGER (0..65535) read-only optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 0 Success
2 - Set Object to Min. Value 0 Success
3 - Set Object to Max. Value 0 Success
4 - Attempt Write to Read-Only Object   Failed - GenErr
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max.   Skipped - not writable
7 - Attempt to Set Value < Min.   Skipped - not writable
8 - Restore Object to Original Value   Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-033
VDOT Implemented: Yes
Std Par Ref 5.4.2.8
OID 1.3.6.1.4.1.1206.4.2.3.3.2.1.8.1
Object Name fontStatus
Syntax Access Status
INTEGER {enumeration} read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 4 (readyForUse) Success
2 - Set Object to Min. Value 4 (readyForUse) Success
3 - Set Object to Max. Value 4 (readyForUse) Success
4 - Attempt Write to Read-Only Object   Skipped - Not read only
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max.   Skipped - no Minimum
7 - Attempt to Set Value < Min.   Skipped - no Minimum
8 - Restore Object to Original Value   Failed - BadValue

Overall Test Case Results: Passed

Object Test Case TC-O-034
VDOT Implemented: Yes
Std Par Ref 5.4.2.8
OID 1.3.6.1.4.1.1206.4.2.3.3.2.1.8.2
Object Name fontStatus
Syntax Access Status
INTEGER {enumeration} read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 1 (notUsed) Success
2 - Set Object to Min. Value 1 (notUsed) Success
3 - Set Object to Max. Value 1 (notUsed) Success
4 - Attempt Write to Read-Only Object   Skipped - Not read only
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max.   Skipped - no Minimum
7 - Attempt to Set Value < Min.   Skipped - no Minimum
8 - Restore Object to Original Value   Failed - BadValue

Overall Test Case Results: Passed

Object Test Case TC-O-035
VDOT Implemented: Yes
Std Par Ref 5.4.2.9
OID 1.3.6.1.4.1.1206.4.2.3.3.2.1.9.1
Object Name fontSupportedCharacterSet
Syntax Access Status
INTEGER (0..255) read-only optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 0 Success
2 - Set Object to Min. Value 0 Success
3 - Set Object to Max. Value 0 Success
4 - Attempt Write to Read-Only Object   Failed - GenErr
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max.   Skipped - not writable
7 - Attempt to Set Value < Min.   Skipped - not writable
8 - Restore Object to Original Value   Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-036
VDOT Implemented: Yes
Std Par Ref 5.4.2.9
OID 1.3.6.1.4.1.1206.4.2.3.3.2.1.9.2
Object Name fontSupportedCharacterSet
Syntax Access Status
INTEGER (0..255) read-only optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 0 Success
2 - Set Object to Min. Value 0 Success
3 - Set Object to Max. Value 0 Success
4 - Attempt Write to Read-Only Object   Failed - GenErr
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max.   Skipped - not writable
7 - Attempt to Set Value < Min.   Skipped - not writable
8 - Restore Object to Original Value   Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-037
VDOT Implemented: Yes
Std Par Ref 5.4.2.10
OID 1.3.6.1.4.1.1206.4.2.3.3.2.1.10.1
Object Name fontAddlSupportedCharacters
Syntax Access Status
OCTET STRING read-only optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 00 Success
2 - Set Object to Min. Value 00 Success
3 - Set Object to Max. Value 00 Success
4 - Attempt Write to Read-Only Object 00 Failed - GenErr
5 - Attempt Read of Non-Accessible Object 00 Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 00 Skipped - not writable
7 - Attempt to Set Value < Min. 00 Skipped - not writable
8 - Restore Object to Original Value 00 Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-038
VDOT Implemented: Yes
Std Par Ref 5.4.2.10
OID 1.3.6.1.4.1.1206.4.2.3.3.2.1.10.2
Object Name fontAddlSupportedCharacters
Syntax Access Status
OCTET STRING read-only optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 00 Success
2 - Set Object to Min. Value 00 Success
3 - Set Object to Max. Value 00 Success
4 - Attempt Write to Read-Only Object 00 Failed - GenErr
5 - Attempt Read of Non-Accessible Object 00 Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 00 Skipped - not writable
7 - Attempt to Set Value < Min. 00 Skipped - not writable
8 - Restore Object to Original Value 00 Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-039
VDOT Implemented: Yes
Std Par Ref 5.4.3
OID 1.3.6.1.4.1.1206.4.2.3.3.3.0
Object Name maxFontCharacters
Syntax Access Status
INTEGER (1..65535) read-only deprectated
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 127 Success
2 - Set Object to Min. Value 127 Success
3 - Set Object to Max. Value 127 Success
4 - Attempt Write to Read-Only Object   Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max.   Skipped - not writable
7 - Attempt to Set Value < Min.   Skipped - not writable
8 - Restore Object to Original Value   Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-040
VDOT Implemented: Yes
Std Par Ref 5.4.4.1
OID 1.3.6.1.4.1.1206.4.2.3.3.4.1.1.1.1
Object Name characterNumber
Syntax Access Status
INTEGER (1..65535) read-only optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 1 Success
2 - Set Object to Min. Value 1 Success
3 - Set Object to Max. Value 1 Success
4 - Attempt Write to Read-Only Object   Failed - GenErr
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max.   Skipped - not writable
7 - Attempt to Set Value < Min.   Skipped - not writable
8 - Restore Object to Original Value   Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-041
VDOT Implemented: Yes
Std Par Ref 5.4.4.1
OID 1.3.6.1.4.1.1206.4.2.3.3.4.1.1.1.10
Object Name characterNumber
Syntax Access Status
INTEGER (1..65535) read-only optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 10 Success
2 - Set Object to Min. Value 10 Success
3 - Set Object to Max. Value 10 Success
4 - Attempt Write to Read-Only Object   Failed - GenErr
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max.   Skipped - not writable
7 - Attempt to Set Value < Min.   Skipped - not writable
8 - Restore Object to Original Value   Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-042
VDOT Implemented: Yes
Std Par Ref 5.4.4.1
OID 1.3.6.1.4.1.1206.4.2.3.3.4.1.1.1.2
Object Name characterNumber
Syntax Access Status
INTEGER (1..65535) read-only optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 2 Success
2 - Set Object to Min. Value 2 Success
3 - Set Object to Max. Value 2 Success
4 - Attempt Write to Read-Only Object   Failed - GenErr
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max.   Skipped - not writable
7 - Attempt to Set Value < Min.   Skipped - not writable
8 - Restore Object to Original Value   Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-043
VDOT Implemented: Yes
Std Par Ref 5.4.4.1
OID 1.3.6.1.4.1.1206.4.2.3.3.4.1.1.1.3
Object Name characterNumber
Syntax Access Status
INTEGER (1..65535) read-only optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 3 Success
2 - Set Object to Min. Value 3 Success
3 - Set Object to Max. Value 3 Success
4 - Attempt Write to Read-Only Object   Failed - GenErr
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max.   Skipped - not writable
7 - Attempt to Set Value < Min.   Skipped - not writable
8 - Restore Object to Original Value   Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-044
VDOT Implemented: Yes
Std Par Ref 5.4.4.1
OID 1.3.6.1.4.1.1206.4.2.3.3.4.1.1.1.4
Object Name characterNumber
Syntax Access Status
INTEGER (1..65535) read-only optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 4 Success
2 - Set Object to Min. Value 4 Success
3 - Set Object to Max. Value 4 Success
4 - Attempt Write to Read-Only Object   Failed - GenErr
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max.   Skipped - not writable
7 - Attempt to Set Value < Min.   Skipped - not writable
8 - Restore Object to Original Value   Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-045
VDOT Implemented: Yes
Std Par Ref 5.4.4.1
OID 1.3.6.1.4.1.1206.4.2.3.3.4.1.1.1.5
Object Name characterNumber
Syntax Access Status
INTEGER (1..65535) read-only optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 5 Success
2 - Set Object to Min. Value 5 Success
3 - Set Object to Max. Value 5 Success
4 - Attempt Write to Read-Only Object   Failed - GenErr
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max.   Skipped - not writable
7 - Attempt to Set Value < Min.   Skipped - not writable
8 - Restore Object to Original Value   Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-046
VDOT Implemented: Yes
Std Par Ref 5.4.4.1
OID 1.3.6.1.4.1.1206.4.2.3.3.4.1.1.1.6
Object Name characterNumber
Syntax Access Status
INTEGER (1..65535) read-only optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 6 Success
2 - Set Object to Min. Value 6 Success
3 - Set Object to Max. Value 6 Success
4 - Attempt Write to Read-Only Object   Failed - GenErr
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max.   Skipped - not writable
7 - Attempt to Set Value < Min.   Skipped - not writable
8 - Restore Object to Original Value   Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-047
VDOT Implemented: Yes
Std Par Ref 5.4.4.1
OID 1.3.6.1.4.1.1206.4.2.3.3.4.1.1.1.7
Object Name characterNumber
Syntax Access Status
INTEGER (1..65535) read-only optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 7 Success
2 - Set Object to Min. Value 7 Success
3 - Set Object to Max. Value 7 Success
4 - Attempt Write to Read-Only Object   Failed - GenErr
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max.   Skipped - not writable
7 - Attempt to Set Value < Min.   Skipped - not writable
8 - Restore Object to Original Value   Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-048
VDOT Implemented: Yes
Std Par Ref 5.4.4.1
OID 1.3.6.1.4.1.1206.4.2.3.3.4.1.1.1.8
Object Name characterNumber
Syntax Access Status
INTEGER (1..65535) read-only optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 8 Success
2 - Set Object to Min. Value 8 Success
3 - Set Object to Max. Value 8 Success
4 - Attempt Write to Read-Only Object   Failed - GenErr
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max.   Skipped - not writable
7 - Attempt to Set Value < Min.   Skipped - not writable
8 - Restore Object to Original Value   Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-049
VDOT Implemented: Yes
Std Par Ref 5.4.4.1
OID 1.3.6.1.4.1.1206.4.2.3.3.4.1.1.1.9
Object Name characterNumber
Syntax Access Status
INTEGER (1..65535) read-only optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 9 Success
2 - Set Object to Min. Value 9 Success
3 - Set Object to Max. Value 9 Success
4 - Attempt Write to Read-Only Object   Failed - GenErr
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max.   Skipped - not writable
7 - Attempt to Set Value < Min.   Skipped - not writable
8 - Restore Object to Original Value   Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-050
VDOT Implemented: Yes
Std Par Ref 5.4.4.1
OID 1.3.6.1.4.1.1206.4.2.3.3.4.1.1.2.1
Object Name characterNumber
Syntax Access Status
INTEGER (1..65535) read-only optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 1 Success
2 - Set Object to Min. Value 1 Success
3 - Set Object to Max. Value 1 Success
4 - Attempt Write to Read-Only Object   Failed - GenErr
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max.   Skipped - not writable
7 - Attempt to Set Value < Min.   Skipped - not writable
8 - Restore Object to Original Value   Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-051
VDOT Implemented: Yes
Std Par Ref 5.4.4.1
OID 1.3.6.1.4.1.1206.4.2.3.3.4.1.1.2.10
Object Name characterNumber
Syntax Access Status
INTEGER (1..65535) read-only optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 10 Success
2 - Set Object to Min. Value 10 Success
3 - Set Object to Max. Value 10 Success
4 - Attempt Write to Read-Only Object   Failed - GenErr
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max.   Skipped - not writable
7 - Attempt to Set Value < Min.   Skipped - not writable
8 - Restore Object to Original Value   Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-052
VDOT Implemented: Yes
Std Par Ref 5.4.4.1
OID 1.3.6.1.4.1.1206.4.2.3.3.4.1.1.2.2
Object Name characterNumber
Syntax Access Status
INTEGER (1..65535) read-only optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 2 Success
2 - Set Object to Min. Value 2 Success
3 - Set Object to Max. Value 2 Success
4 - Attempt Write to Read-Only Object   Failed - GenErr
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max.   Skipped - not writable
7 - Attempt to Set Value < Min.   Skipped - not writable
8 - Restore Object to Original Value   Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-053
VDOT Implemented: Yes
Std Par Ref 5.4.4.1
OID 1.3.6.1.4.1.1206.4.2.3.3.4.1.1.2.3
Object Name characterNumber
Syntax Access Status
INTEGER (1..65535) read-only optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 3 Success
2 - Set Object to Min. Value 3 Success
3 - Set Object to Max. Value 3 Success
4 - Attempt Write to Read-Only Object   Failed - GenErr
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max.   Skipped - not writable
7 - Attempt to Set Value < Min.   Skipped - not writable
8 - Restore Object to Original Value   Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-054
VDOT Implemented: Yes
Std Par Ref 5.4.4.1
OID 1.3.6.1.4.1.1206.4.2.3.3.4.1.1.2.4
Object Name characterNumber
Syntax Access Status
INTEGER (1..65535) read-only optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 4 Success
2 - Set Object to Min. Value 4 Success
3 - Set Object to Max. Value 4 Success
4 - Attempt Write to Read-Only Object   Failed - GenErr
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max.   Skipped - not writable
7 - Attempt to Set Value < Min.   Skipped - not writable
8 - Restore Object to Original Value   Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-055
VDOT Implemented: Yes
Std Par Ref 5.4.4.1
OID 1.3.6.1.4.1.1206.4.2.3.3.4.1.1.2.5
Object Name characterNumber
Syntax Access Status
INTEGER (1..65535) read-only optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 5 Success
2 - Set Object to Min. Value 5 Success
3 - Set Object to Max. Value 5 Success
4 - Attempt Write to Read-Only Object   Failed - GenErr
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max.   Skipped - not writable
7 - Attempt to Set Value < Min.   Skipped - not writable
8 - Restore Object to Original Value   Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-056
VDOT Implemented: Yes
Std Par Ref 5.4.4.1
OID 1.3.6.1.4.1.1206.4.2.3.3.4.1.1.2.6
Object Name characterNumber
Syntax Access Status
INTEGER (1..65535) read-only optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 6 Success
2 - Set Object to Min. Value 6 Success
3 - Set Object to Max. Value 6 Success
4 - Attempt Write to Read-Only Object   Failed - GenErr
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max.   Skipped - not writable
7 - Attempt to Set Value < Min.   Skipped - not writable
8 - Restore Object to Original Value   Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-057
VDOT Implemented: Yes
Std Par Ref 5.4.4.1
OID 1.3.6.1.4.1.1206.4.2.3.3.4.1.1.2.7
Object Name characterNumber
Syntax Access Status
INTEGER (1..65535) read-only optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 7 Success
2 - Set Object to Min. Value 7 Success
3 - Set Object to Max. Value 7 Success
4 - Attempt Write to Read-Only Object   Failed - GenErr
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max.   Skipped - not writable
7 - Attempt to Set Value < Min.   Skipped - not writable
8 - Restore Object to Original Value   Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-058
VDOT Implemented: Yes
Std Par Ref 5.4.4.1
OID 1.3.6.1.4.1.1206.4.2.3.3.4.1.1.2.8
Object Name characterNumber
Syntax Access Status
INTEGER (1..65535) read-only optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 8 Success
2 - Set Object to Min. Value 8 Success
3 - Set Object to Max. Value 8 Success
4 - Attempt Write to Read-Only Object   Failed - GenErr
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max.   Skipped - not writable
7 - Attempt to Set Value < Min.   Skipped - not writable
8 - Restore Object to Original Value   Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-059
VDOT Implemented: Yes
Std Par Ref 5.4.4.1
OID 1.3.6.1.4.1.1206.4.2.3.3.4.1.1.2.9
Object Name characterNumber
Syntax Access Status
INTEGER (1..65535) read-only optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 9 Success
2 - Set Object to Min. Value 9 Success
3 - Set Object to Max. Value 9 Success
4 - Attempt Write to Read-Only Object   Failed - GenErr
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max.   Skipped - not writable
7 - Attempt to Set Value < Min.   Skipped - not writable
8 - Restore Object to Original Value   Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-060
VDOT Implemented: Yes
Std Par Ref 5.4.4.2
OID 1.3.6.1.4.1.1206.4.2.3.3.4.1.2.1.1
Object Name characterWidth
Syntax Access Status
INTEGER (0..255) read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 0 Success
2 - Set Object to Min. Value 0 Success
3 - Set Object to Max. Value 0 Success
4 - Attempt Write to Read-Only Object   Skipped - Not read only
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 256 Success - did not write greater than Max
7 - Attempt to Set Value < Min. -1 Success - did not write less than Min
8 - Restore Object to Original Value   Failed - GenErr

Overall Test Case Results: Passed

Object Test Case TC-O-061
VDOT Implemented: Yes
Std Par Ref 5.4.4.2
OID 1.3.6.1.4.1.1206.4.2.3.3.4.1.2.1.10
Object Name characterWidth
Syntax Access Status
INTEGER (0..255) read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 0 Success
2 - Set Object to Min. Value 0 Success
3 - Set Object to Max. Value 0 Success
4 - Attempt Write to Read-Only Object   Skipped - Not read only
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 256 Success - did not write greater than Max
7 - Attempt to Set Value < Min. -1 Success - did not write less than Min
8 - Restore Object to Original Value   Failed - GenErr

Overall Test Case Results: Passed

Object Test Case TC-O-062
VDOT Implemented: Yes
Std Par Ref 5.4.4.2
OID 1.3.6.1.4.1.1206.4.2.3.3.4.1.2.1.2
Object Name characterWidth
Syntax Access Status
INTEGER (0..255) read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 0 Success
2 - Set Object to Min. Value 0 Success
3 - Set Object to Max. Value 0 Success
4 - Attempt Write to Read-Only Object   Skipped - Not read only
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 256 Success - did not write greater than Max
7 - Attempt to Set Value < Min. -1 Success - did not write less than Min
8 - Restore Object to Original Value   Failed - GenErr

Overall Test Case Results: Passed

Object Test Case TC-O-063
VDOT Implemented: Yes
Std Par Ref 5.4.4.2
OID 1.3.6.1.4.1.1206.4.2.3.3.4.1.2.1.3
Object Name characterWidth
Syntax Access Status
INTEGER (0..255) read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 0 Success
2 - Set Object to Min. Value 0 Success
3 - Set Object to Max. Value 0 Success
4 - Attempt Write to Read-Only Object   Skipped - Not read only
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 256 Success - did not write greater than Max
7 - Attempt to Set Value < Min. -1 Success - did not write less than Min
8 - Restore Object to Original Value   Failed - GenErr

Overall Test Case Results: Passed

Object Test Case TC-O-064
VDOT Implemented: Yes
Std Par Ref 5.4.4.2
OID 1.3.6.1.4.1.1206.4.2.3.3.4.1.2.1.4
Object Name characterWidth
Syntax Access Status
INTEGER (0..255) read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 0 Success
2 - Set Object to Min. Value 0 Success
3 - Set Object to Max. Value 0 Success
4 - Attempt Write to Read-Only Object   Skipped - Not read only
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 256 Success - did not write greater than Max
7 - Attempt to Set Value < Min. -1 Success - did not write less than Min
8 - Restore Object to Original Value   Failed - GenErr

Overall Test Case Results: Passed

Object Test Case TC-O-065
VDOT Implemented: Yes
Std Par Ref 5.4.4.2
OID 1.3.6.1.4.1.1206.4.2.3.3.4.1.2.1.5
Object Name characterWidth
Syntax Access Status
INTEGER (0..255) read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 0 Success
2 - Set Object to Min. Value 0 Success
3 - Set Object to Max. Value 0 Success
4 - Attempt Write to Read-Only Object   Skipped - Not read only
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 256 Success - did not write greater than Max
7 - Attempt to Set Value < Min. -1 Success - did not write less than Min
8 - Restore Object to Original Value   Failed - GenErr

Overall Test Case Results: Passed

Object Test Case TC-O-066
VDOT Implemented: Yes
Std Par Ref 5.4.4.2
OID 1.3.6.1.4.1.1206.4.2.3.3.4.1.2.1.6
Object Name characterWidth
Syntax Access Status
INTEGER (0..255) read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 0 Success
2 - Set Object to Min. Value 0 Success
3 - Set Object to Max. Value 0 Success
4 - Attempt Write to Read-Only Object   Skipped - Not read only
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 256 Success - did not write greater than Max
7 - Attempt to Set Value < Min. -1 Success - did not write less than Min
8 - Restore Object to Original Value   Failed - GenErr

Overall Test Case Results: Passed

Object Test Case TC-O-067
VDOT Implemented: Yes
Std Par Ref 5.4.4.2
OID 1.3.6.1.4.1.1206.4.2.3.3.4.1.2.1.7
Object Name characterWidth
Syntax Access Status
INTEGER (0..255) read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 0 Success
2 - Set Object to Min. Value 0 Success
3 - Set Object to Max. Value 0 Success
4 - Attempt Write to Read-Only Object   Skipped - Not read only
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 256 Success - did not write greater than Max
7 - Attempt to Set Value < Min. -1 Success - did not write less than Min
8 - Restore Object to Original Value   Failed - GenErr

Overall Test Case Results: Passed

Object Test Case TC-O-068
VDOT Implemented: Yes
Std Par Ref 5.4.4.2
OID 1.3.6.1.4.1.1206.4.2.3.3.4.1.2.1.8
Object Name characterWidth
Syntax Access Status
INTEGER (0..255) read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 0 Success
2 - Set Object to Min. Value 0 Success
3 - Set Object to Max. Value 0 Success
4 - Attempt Write to Read-Only Object   Skipped - Not read only
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 256 Success - did not write greater than Max
7 - Attempt to Set Value < Min. -1 Success - did not write less than Min
8 - Restore Object to Original Value   Failed - GenErr

Overall Test Case Results: Passed

Object Test Case TC-O-069
VDOT Implemented: Yes
Std Par Ref 5.4.4.2
OID 1.3.6.1.4.1.1206.4.2.3.3.4.1.2.1.9
Object Name characterWidth
Syntax Access Status
INTEGER (0..255) read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 0 Success
2 - Set Object to Min. Value 0 Success
3 - Set Object to Max. Value 0 Success
4 - Attempt Write to Read-Only Object   Skipped - Not read only
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 256 Success - did not write greater than Max
7 - Attempt to Set Value < Min. -1 Success - did not write less than Min
8 - Restore Object to Original Value   Failed - GenErr

Overall Test Case Results: Passed

Object Test Case TC-O-070
VDOT Implemented: Yes
Std Par Ref 5.4.4.2
OID 1.3.6.1.4.1.1206.4.2.3.3.4.1.2.2.1
Object Name characterWidth
Syntax Access Status
INTEGER (0..255) read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 0 Success
2 - Set Object to Min. Value 0 Success
3 - Set Object to Max. Value 0 Success
4 - Attempt Write to Read-Only Object   Skipped - Not read only
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 256 Success - did not write greater than Max
7 - Attempt to Set Value < Min. -1 Success - did not write less than Min
8 - Restore Object to Original Value   Failed - GenErr

Overall Test Case Results: Passed

Object Test Case TC-O-071
VDOT Implemented: Yes
Std Par Ref 5.4.4.2
OID 1.3.6.1.4.1.1206.4.2.3.3.4.1.2.2.10
Object Name characterWidth
Syntax Access Status
INTEGER (0..255) read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 0 Success
2 - Set Object to Min. Value 0 Success
3 - Set Object to Max. Value 0 Success
4 - Attempt Write to Read-Only Object  Skipped - Not read only
5 - Attempt Read of Non-Accessible Object  Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 256 Success - did not write greater than Max
7 - Attempt to Set Value < Min. -1 Success - did not write less than Min
8 - Restore Object to Original Value   Failed - GenErr

Overall Test Case Results: Passed

Object Test Case TC-O-072
VDOT Implemented: Yes
Std Par Ref 5.4.4.2
OID 1.3.6.1.4.1.1206.4.2.3.3.4.1.2.2.2
Object Name characterWidth
Syntax Access Status
INTEGER (0..255) read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 0 Success
2 - Set Object to Min. Value 0 Success
3 - Set Object to Max. Value 0 Success
4 - Attempt Write to Read-Only Object   Skipped - Not read only
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 256 Success - did not write greater than Max
7 - Attempt to Set Value < Min. -1 Success - did not write less than Min
8 - Restore Object to Original Value   Failed - GenErr

Overall Test Case Results: Passed

Object Test Case TC-O-073
VDOT Implemented: Yes
Std Par Ref 5.4.4.2
OID 1.3.6.1.4.1.1206.4.2.3.3.4.1.2.2.3
Object Name characterWidth
Syntax Access Status
INTEGER (0..255) read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 0 Success
2 - Set Object to Min. Value 0 Success
3 - Set Object to Max. Value 0 Success
4 - Attempt Write to Read-Only Object   Skipped - Not read only
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 256 Success - did not write greater than Max
7 - Attempt to Set Value < Min. -1 Success - did not write less than Min
8 - Restore Object to Original Value   Failed - GenErr

Overall Test Case Results: Passed

Object Test Case TC-O-074
VDOT Implemented: Yes
Std Par Ref 5.4.4.2
OID 1.3.6.1.4.1.1206.4.2.3.3.4.1.2.2.4
Object Name characterWidth
Syntax Access Status
INTEGER (0..255) read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 0 Success
2 - Set Object to Min. Value 0 Success
3 - Set Object to Max. Value 0 Success
4 - Attempt Write to Read-Only Object  Skipped - Not read only
5 - Attempt Read of Non-Accessible Object  Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 256 Success - did not write greater than Max
7 - Attempt to Set Value < Min. -1 Success - did not write less than Min
8 - Restore Object to Original Value   Failed - GenErr

Overall Test Case Results: Passed

Object Test Case TC-O-075
VDOT Implemented: Yes
Std Par Ref 5.4.4.2
OID 1.3.6.1.4.1.1206.4.2.3.3.4.1.2.2.5
Object Name characterWidth
Syntax Access Status
INTEGER (0..255) read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 0 Success
2 - Set Object to Min. Value 0 Success
3 - Set Object to Max. Value 0 Success
4 - Attempt Write to Read-Only Object   Skipped - Not read only
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 256 Success - did not write greater than Max
7 - Attempt to Set Value < Min. -1 Success - did not write less than Min
8 - Restore Object to Original Value   Failed - GenErr

Overall Test Case Results: Passed

Object Test Case TC-O-076
VDOT Implemented: Yes
Std Par Ref 5.4.4.2
OID 1.3.6.1.4.1.1206.4.2.3.3.4.1.2.2.6
Object Name characterWidth
Syntax Access Status
INTEGER (0..255) read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 0 Success
2 - Set Object to Min. Value 0 Success
3 - Set Object to Max. Value 0 Success
4 - Attempt Write to Read-Only Object   Skipped - Not read only
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 256 Success - did not write greater than Max
7 - Attempt to Set Value < Min. -1 Success - did not write less than Min
8 - Restore Object to Original Value   Failed - GenErr

Overall Test Case Results: Passed

Object Test Case TC-O-077
VDOT Implemented: Yes
Std Par Ref 5.4.4.2
OID 1.3.6.1.4.1.1206.4.2.3.3.4.1.2.2.7
Object Name characterWidth
Syntax Access Status
INTEGER (0..255) read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 0 Success
2 - Set Object to Min. Value 0 Success
3 - Set Object to Max. Value 0 Success
4 - Attempt Write to Read-Only Object   Skipped - Not read only
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 256 Success - did not write greater than Max
7 - Attempt to Set Value < Min. -1 Success - did not write less than Min
8 - Restore Object to Original Value   Failed - GenErr

Overall Test Case Results: Passed

Object Test Case TC-O-078
VDOT Implemented: Yes
Std Par Ref 5.4.4.2
OID 1.3.6.1.4.1.1206.4.2.3.3.4.1.2.2.8
Object Name characterWidth
Syntax Access Status
INTEGER (0..255) read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 0 Success
2 - Set Object to Min. Value 0 Success
3 - Set Object to Max. Value 0 Success
4 - Attempt Write to Read-Only Object   Skipped - Not read only
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 256 Success - did not write greater than Max
7 - Attempt to Set Value < Min. -1 Success - did not write less than Min
8 - Restore Object to Original Value   Failed - GenErr

Overall Test Case Results: Passed

Object Test Case TC-O-079
VDOT Implemented: Yes
Std Par Ref 5.4.4.2
OID 1.3.6.1.4.1.1206.4.2.3.3.4.1.2.2.9
Object Name characterWidth
Syntax Access Status
INTEGER (0..255) read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 0 Success
2 - Set Object to Min. Value 0 Success
3 - Set Object to Max. Value 0 Success
4 - Attempt Write to Read-Only Object   Skipped - Not read only
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 256 Success - did not write greater than Max
7 - Attempt to Set Value < Min. -1 Success - did not write less than Min
8 - Restore Object to Original Value   Failed - GenErr

Overall Test Case Results: Passed

Object Test Case TC-O-080
VDOT Implemented: Yes
Std Par Ref 5.4.4.3
OID 1.3.6.1.4.1.1206.4.2.3.3.4.1.3.1.1
Object Name characterBitmap
Syntax Access Status
OCTET STRING read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object   Success
2 - Set Object to Min. Value   Success
3 - Set Object to Max. Value   Success
4 - Attempt Write to Read-Only Object 00 Skipped - Not read only
5 - Attempt Read of Non-Accessible Object 00 Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 00 Skipped - no Minimum
7 - Attempt to Set Value < Min. 00 Skipped - no Minimum
8 - Restore Object to Original Value 00 Failed - GenErr

Overall Test Case Results: Passed

Object Test Case TC-O-081
VDOT Implemented: Yes
Std Par Ref 5.4.4.3
OID 1.3.6.1.4.1.1206.4.2.3.3.4.1.3.1.10
Object Name characterBitmap
Syntax Access Status
OCTET STRING read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object   Success
2 - Set Object to Min. Value   Success
3 - Set Object to Max. Value   Success
4 - Attempt Write to Read-Only Object 00 Skipped - Not read only
5 - Attempt Read of Non-Accessible Object 00 Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 00 Skipped - no Minimum
7 - Attempt to Set Value < Min. 00 Skipped - no Minimum
8 - Restore Object to Original Value 00 Failed - GenErr

Overall Test Case Results: Passed

Object Test Case TC-O-082
VDOT Implemented: Yes
Std Par Ref 5.4.4.3
OID 1.3.6.1.4.1.1206.4.2.3.3.4.1.3.1.2
Object Name characterBitmap
Syntax Access Status
OCTET STRING read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object   Success
2 - Set Object to Min. Value   Success
3 - Set Object to Max. Value   Success
4 - Attempt Write to Read-Only Object 00 Skipped - Not read only
5 - Attempt Read of Non-Accessible Object 00 Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 00 Skipped - no Minimum
7 - Attempt to Set Value < Min. 00 Skipped - no Minimum
8 - Restore Object to Original Value 00 Failed - GenErr

Overall Test Case Results: Passed

Object Test Case TC-O-083
VDOT Implemented: Yes
Std Par Ref 5.4.4.3
OID 1.3.6.1.4.1.1206.4.2.3.3.4.1.3.1.3
Object Name characterBitmap
Syntax Access Status
OCTET STRING read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object   Success
2 - Set Object to Min. Value   Success
3 - Set Object to Max. Value   Success
4 - Attempt Write to Read-Only Object 00 Skipped - Not read only
5 - Attempt Read of Non-Accessible Object 00 Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 00 Skipped - no Minimum
7 - Attempt to Set Value < Min. 00 Skipped - no Minimum
8 - Restore Object to Original Value 00 Failed - GenErr

Overall Test Case Results: Passed

Object Test Case TC-O-084
VDOT Implemented: Yes
Std Par Ref 5.4.4.3
OID 1.3.6.1.4.1.1206.4.2.3.3.4.1.3.1.4
Object Name characterBitmap
Syntax Access Status
OCTET STRING read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object   Success
2 - Set Object to Min. Value   Success
3 - Set Object to Max. Value   Success
4 - Attempt Write to Read-Only Object 00 Skipped - Not read only
5 - Attempt Read of Non-Accessible Object 00 Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 00 Skipped - no Minimum
7 - Attempt to Set Value < Min. 00 Skipped - no Minimum
8 - Restore Object to Original Value 00 Failed - GenErr

Overall Test Case Results: Passed

Object Test Case TC-O-085
VDOT Implemented: Yes
Std Par Ref 5.4.4.3
OID 1.3.6.1.4.1.1206.4.2.3.3.4.1.3.1.5
Object Name characterBitmap
Syntax Access Status
OCTET STRING read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object   Success
2 - Set Object to Min. Value   Success
3 - Set Object to Max. Value   Success
4 - Attempt Write to Read-Only Object 00 Skipped - Not read only
5 - Attempt Read of Non-Accessible Object 00 Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 00 Skipped - no Minimum
7 - Attempt to Set Value < Min. 00 Skipped - no Minimum
8 - Restore Object to Original Value 00 Failed - GenErr

Overall Test Case Results: Passed

Object Test Case TC-O-086
VDOT Implemented: Yes
Std Par Ref 5.4.4.3
OID 1.3.6.1.4.1.1206.4.2.3.3.4.1.3.1.6
Object Name characterBitmap
Syntax Access Status
OCTET STRING read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object   Success
2 - Set Object to Min. Value   Success
3 - Set Object to Max. Value   Success
4 - Attempt Write to Read-Only Object 00 Skipped - Not read only
5 - Attempt Read of Non-Accessible Object 00 Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 00 Skipped - no Minimum
7 - Attempt to Set Value < Min. 00 Skipped - no Minimum
8 - Restore Object to Original Value 00 Failed - GenErr

Overall Test Case Results: Passed

Object Test Case TC-O-087
VDOT Implemented: Yes
Std Par Ref 5.4.4.3
OID 1.3.6.1.4.1.1206.4.2.3.3.4.1.3.1.7
Object Name characterBitmap
Syntax Access Status
OCTET STRING read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object   Success
2 - Set Object to Min. Value   Success
3 - Set Object to Max. Value   Success
4 - Attempt Write to Read-Only Object 00 Skipped - Not read only
5 - Attempt Read of Non-Accessible Object 00 Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 00 Skipped - no Minimum
7 - Attempt to Set Value < Min. 00 Skipped - no Minimum
8 - Restore Object to Original Value 00 Failed - GenErr

Overall Test Case Results: Passed

Object Test Case TC-O-088
VDOT Implemented: Yes
Std Par Ref 5.4.4.3
OID 1.3.6.1.4.1.1206.4.2.3.3.4.1.3.1.8
Object Name characterBitmap
Syntax Access Status
OCTET STRING read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object   Success
2 - Set Object to Min. Value   Success
3 - Set Object to Max. Value   Success
4 - Attempt Write to Read-Only Object 00 Skipped - Not read only
5 - Attempt Read of Non-Accessible Object 00 Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 00 Skipped - no Minimum
7 - Attempt to Set Value < Min. 00 Skipped - no Minimum
8 - Restore Object to Original Value 00 Failed - GenErr

Overall Test Case Results: Passed

Object Test Case TC-O-089
VDOT Implemented: Yes
Std Par Ref 5.4.4.3
OID 1.3.6.1.4.1.1206.4.2.3.3.4.1.3.1.9
Object Name characterBitmap
Syntax Access Status
OCTET STRING read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object   Success
2 - Set Object to Min. Value   Success
3 - Set Object to Max. Value   Success
4 - Attempt Write to Read-Only Object 00 Skipped - Not read only
5 - Attempt Read of Non-Accessible Object 00 Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 00 Skipped - no Minimum
7 - Attempt to Set Value < Min. 00 Skipped - no Minimum
8 - Restore Object to Original Value 00 Failed - GenErr

Overall Test Case Results: Passed

Object Test Case TC-O-090
VDOT Implemented: Yes
Std Par Ref 5.4.4.3
OID 1.3.6.1.4.1.1206.4.2.3.3.4.1.3.2.1
Object Name characterBitmap
Syntax Access Status
OCTET STRING read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object   Success
2 - Set Object to Min. Value   Success
3 - Set Object to Max. Value   Success
4 - Attempt Write to Read-Only Object 00 Skipped - Not read only
5 - Attempt Read of Non-Accessible Object 00 Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 00 Skipped - no Minimum
7 - Attempt to Set Value < Min. 00 Skipped - no Minimum
8 - Restore Object to Original Value 00 Failed - GenErr

Overall Test Case Results: Passed

Object Test Case TC-O-091
VDOT Implemented: Yes
Std Par Ref 5.4.4.3
OID 1.3.6.1.4.1.1206.4.2.3.3.4.1.3.2.10
Object Name characterBitmap
Syntax Access Status
OCTET STRING read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object   Success
2 - Set Object to Min. Value   Success
3 - Set Object to Max. Value   Success
4 - Attempt Write to Read-Only Object 00 Skipped - Not read only
5 - Attempt Read of Non-Accessible Object 00 Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 00 Skipped - no Minimum
7 - Attempt to Set Value < Min. 00 Skipped - no Minimum
8 - Restore Object to Original Value 00 Failed - GenErr

Overall Test Case Results: Passed

Object Test Case TC-O-092
VDOT Implemented: Yes
Std Par Ref 5.4.4.3
OID 1.3.6.1.4.1.1206.4.2.3.3.4.1.3.2.2
Object Name characterBitmap
Syntax Access Status
OCTET STRING read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object   Success
2 - Set Object to Min. Value   Success
3 - Set Object to Max. Value   Success
4 - Attempt Write to Read-Only Object 00 Skipped - Not read only
5 - Attempt Read of Non-Accessible Object 00 Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 00 Skipped - no Minimum
7 - Attempt to Set Value < Min. 00 Skipped - no Minimum
8 - Restore Object to Original Value 00 Failed - GenErr

Overall Test Case Results: Passed

Object Test Case TC-O-093
VDOT Implemented: Yes
Std Par Ref 5.4.4.3
OID 1.3.6.1.4.1.1206.4.2.3.3.4.1.3.2.3
Object Name characterBitmap
Syntax Access Status
OCTET STRING read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object   Success
2 - Set Object to Min. Value   Success
3 - Set Object to Max. Value   Success
4 - Attempt Write to Read-Only Object 00 Skipped - Not read only
5 - Attempt Read of Non-Accessible Object 00 Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 00 Skipped - no Minimum
7 - Attempt to Set Value < Min. 00 Skipped - no Minimum
8 - Restore Object to Original Value 00 Failed - GenErr

Overall Test Case Results: Passed

Object Test Case TC-O-094
VDOT Implemented: Yes
Std Par Ref 5.4.4.3
OID 1.3.6.1.4.1.1206.4.2.3.3.4.1.3.2.4
Object Name characterBitmap
Syntax Access Status
OCTET STRING read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object   Success
2 - Set Object to Min. Value   Success
3 - Set Object to Max. Value   Success
4 - Attempt Write to Read-Only Object 00 Skipped - Not read only
5 - Attempt Read of Non-Accessible Object 00 Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 00 Skipped - no Minimum
7 - Attempt to Set Value < Min. 00 Skipped - no Minimum
8 - Restore Object to Original Value 00 Failed - GenErr

Overall Test Case Results: Passed

Object Test Case TC-O-095
VDOT Implemented: Yes
Std Par Ref 5.4.4.3
OID 1.3.6.1.4.1.1206.4.2.3.3.4.1.3.2.5
Object Name characterBitmap
Syntax Access Status
OCTET STRING read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object   Success
2 - Set Object to Min. Value   Success
3 - Set Object to Max. Value   Success
4 - Attempt Write to Read-Only Object 00 Skipped - Not read only
5 - Attempt Read of Non-Accessible Object 00 Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 00 Skipped - no Minimum
7 - Attempt to Set Value < Min. 00 Skipped - no Minimum
8 - Restore Object to Original Value 00 Failed - GenErr

Overall Test Case Results: Passed

Object Test Case TC-O-096
VDOT Implemented: Yes
Std Par Ref 5.4.4.3
OID 1.3.6.1.4.1.1206.4.2.3.3.4.1.3.2.6
Object Name characterBitmap
Syntax Access Status
OCTET STRING read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object   Success
2 - Set Object to Min. Value   Success
3 - Set Object to Max. Value   Success
4 - Attempt Write to Read-Only Object 00 Skipped - Not read only
5 - Attempt Read of Non-Accessible Object 00 Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 00 Skipped - no Minimum
7 - Attempt to Set Value < Min. 00 Skipped - no Minimum
8 - Restore Object to Original Value 00 Failed - GenErr

Overall Test Case Results: Passed

Object Test Case TC-O-097
VDOT Implemented: Yes
Std Par Ref 5.4.4.3
OID 1.3.6.1.4.1.1206.4.2.3.3.4.1.3.2.7
Object Name characterBitmap
Syntax Access Status
OCTET STRING read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object   Success
2 - Set Object to Min. Value   Success
3 - Set Object to Max. Value   Success
4 - Attempt Write to Read-Only Object 00 Skipped - Not read only
5 - Attempt Read of Non-Accessible Object 00 Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 00 Skipped - no Minimum
7 - Attempt to Set Value < Min. 00 Skipped - no Minimum
8 - Restore Object to Original Value 00 Failed - GenErr

Overall Test Case Results: Passed

Object Test Case TC-O-098
VDOT Implemented: Yes
Std Par Ref 5.4.4.3
OID 1.3.6.1.4.1.1206.4.2.3.3.4.1.3.2.8
Object Name characterBitmap
Syntax Access Status
OCTET STRING read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object   Success
2 - Set Object to Min. Value   Success
3 - Set Object to Max. Value   Success
4 - Attempt Write to Read-Only Object 00 Skipped - Not read only
5 - Attempt Read of Non-Accessible Object 00 Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 00 Skipped - no Minimum
7 - Attempt to Set Value < Min. 00 Skipped - no Minimum
8 - Restore Object to Original Value 00 Failed - GenErr

Overall Test Case Results: Passed

Object Test Case TC-O-099
VDOT Implemented: Yes
Std Par Ref 5.4.4.3
OID 1.3.6.1.4.1.1206.4.2.3.3.4.1.3.2.9
Object Name characterBitmap
Syntax Access Status
OCTET STRING read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object   Success
2 - Set Object to Min. Value   Success
3 - Set Object to Max. Value   Success
4 - Attempt Write to Read-Only Object 00 Skipped - Not read only
5 - Attempt Read of Non-Accessible Object 00 Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 00 Skipped - no Minimum
7 - Attempt to Set Value < Min. 00 Skipped - no Minimum
8 - Restore Object to Original Value 00 Failed - GenErr

Overall Test Case Results: Passed

Object Test Case TC-O-100
VDOT Implemented: Yes
Std Par Ref 5.4.5
OID 1.3.6.1.4.1.1206.4.2.3.3.7.0
Object Name fontMaxCharacterSize
Syntax Access Status
INTEGER (0..255) read-only optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 49 Success
2 - Set Object to Min. Value 49 Success
3 - Set Object to Max. Value 49 Success
4 - Attempt Write to Read-Only Object   Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max.   Skipped - not writable
7 - Attempt to Set Value < Min.   Skipped - not writable
8 - Restore Object to Original Value   Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-101
VDOT Implemented: Yes
Std Par Ref 5.5.1
OID 1.3.6.1.4.1.1206.4.2.3.4.1.0
Object Name defaultBackgroundColor
Syntax Access Status
INTEGER (0..255) read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 0 Success
2 - Set Object to Min. Value 0 Success
3 - Set Object to Max. Value 0 Success
4 - Attempt Write to Read-Only Object   Skipped - Not read only
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 256 Success - did not write greater than Max
7 - Attempt to Set Value < Min. -1 Success - did not write less than Min
8 - Restore Object to Original Value 0 Success

Overall Test Case Results: Passed

Object Test Case TC-O-102
VDOT Implemented: Yes
Std Par Ref 5.5.2
OID 1.3.6.1.4.1.1206.4.2.3.4.15.0
Object Name defaultBackgroundColorActivate
Syntax Access Status
INTEGER (0..255) read-only optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 0 Success
2 - Set Object to Min. Value 0 Success
3 - Set Object to Max. Value 0 Success
4 - Attempt Write to Read-Only Object   Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max.   Skipped - not writable
7 - Attempt to Set Value < Min.   Skipped - not writable
8 - Restore Object to Original Value   Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-103
VDOT Implemented: Yes
Std Par Ref 5.5.3
OID 1.3.6.1.4.1.1206.4.2.3.4.2.0
Object Name defaultForegroundColor
Syntax Access Status
INTEGER (0..255) read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 9 Success
2 - Set Object to Min. Value 0 Success
3 - Set Object to Max. Value 0 Success
4 - Attempt Write to Read-Only Object   Skipped - Not read only
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 256 Success - did not write greater than Max
7 - Attempt to Set Value < Min. -1 Success - did not write less than Min
8 - Restore Object to Original Value 9 Success

Overall Test Case Results: Passed

Object Test Case TC-O-104
VDOT Implemented: Yes
Std Par Ref 5.5.4
OID 1.3.6.1.4.1.1206.4.2.3.4.16.0
Object Name defaultForegroundColorActivate
Syntax Access Status
INTEGER (0..255) read-only optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 9 Success
2 - Set Object to Min. Value 0 Success
3 - Set Object to Max. Value 0 Success
4 - Attempt Write to Read-Only Object   Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max.   Skipped - not writable
7 - Attempt to Set Value < Min.   Skipped - not writable
8 - Restore Object to Original Value   Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-105
VDOT Implemented: Yes
Std Par Ref 5.5.5
OID 1.3.6.1.4.1.1206.4.2.3.4.3.0
Object Name defaultFlashOn
Syntax Access Status
INTEGER (0..255) read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 5 Success
2 - Set Object to Min. Value 0 Success
3 - Set Object to Max. Value 255 Success
4 - Attempt Write to Read-Only Object   Skipped - Not read only
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 256 Success - did not write greater than Max
7 - Attempt to Set Value < Min. -1 Failed - wrote less than Min
8 - Restore Object to Original Value 5 Success

Overall Test Case Results: Passed

Object Test Case TC-O-106
VDOT Implemented: Yes
Std Par Ref 5.5.6
OID 1.3.6.1.4.1.1206.4.2.3.4.17.0
Object Name defaultFlashOnActivate
Syntax Access Status
INTEGER (0..255) read-only optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 5 Success
2 - Set Object to Min. Value 0 Success
3 - Set Object to Max. Value 255 Success
4 - Attempt Write to Read-Only Object   Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max.   Skipped - not writable
7 - Attempt to Set Value < Min.   Skipped - not writable
8 - Restore Object to Original Value   Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-107
VDOT Implemented: Yes
Std Par Ref 5.5.7
OID 1.3.6.1.4.1.1206.4.2.3.4.4.0
Object Name defaultFlashOff
Syntax Access Status
INTEGER (0..255) read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 5 Success
2 - Set Object to Min. Value 0 Success
3 - Set Object to Max. Value 255 Success
4 - Attempt Write to Read-Only Object   Skipped - Not read only
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 256 Success - did not write greater than Max
7 - Attempt to Set Value < Min. -1 Failed - wrote less than Min
8 - Restore Object to Original Value 5 Success

Overall Test Case Results: Passed

Object Test Case TC-O-108
VDOT Implemented: Yes
Std Par Ref 5.5.8
OID 1.3.6.1.4.1.1206.4.2.3.4.18.0
Object Name defaultFlashOffActivate
Syntax Access Status
INTEGER (0..255) read-only optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 5 Success
2 - Set Object to Min. Value 0 Success
3 - Set Object to Max. Value 255 Success
4 - Attempt Write to Read-Only Object   Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max.   Skipped - not writable
7 - Attempt to Set Value < Min.   Skipped - not writable
8 - Restore Object to Original Value   Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-109
VDOT Implemented: Yes
Std Par Ref 5.5.9
OID 1.3.6.1.4.1.1206.4.2.3.4.5.0
Object Name defaultFont
Syntax Access Status
INTEGER (1..255) read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 1 Success
2 - Set Object to Min. Value 1 Success
3 - Set Object to Max. Value 255 Success
4 - Attempt Write to Read-Only Object   Skipped - Not read only
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 256 Success - did not write greater than Max
7 - Attempt to Set Value < Min. 0 Success - did not write less than Min
8 - Restore Object to Original Value 1 Success

Overall Test Case Results: Passed

Object Test Case TC-O-110
VDOT Implemented: Yes
Std Par Ref 5.5.10
OID 1.3.6.1.4.1.1206.4.2.3.4.19.0
Object Name defaultFontActivate
Syntax Access Status
INTEGER (1..255) read-only optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 1 Success
2 - Set Object to Min. Value 1 Success
3 - Set Object to Max. Value 255 Success
4 - Attempt Write to Read-Only Object   Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max.   Skipped - not writable
7 - Attempt to Set Value < Min.   Skipped - not writable
8 - Restore Object to Original Value   Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-111
VDOT Implemented: Yes
Std Par Ref 5.5.11
OID 1.3.6.1.4.1.1206.4.2.3.4.6.0
Object Name defaultJustificationLine
Syntax Access Status
INTEGER {enumeration} read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 2 (left) Success
2 - Set Object to Min. Value 2 (left) Success
3 - Set Object to Max. Value 2 (left) Success
4 - Attempt Write to Read-Only Object   Skipped - Not read only
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max.   Skipped - no Minimum
7 - Attempt to Set Value < Min.   Skipped - no Minimum
8 - Restore Object to Original Value 2 (left) Success

Overall Test Case Results: Passed

Object Test Case TC-O-112
VDOT Implemented: Yes
Std Par Ref 5.5.12
OID 1.3.6.1.4.1.1206.4.2.3.4.20.0
Object Name defaultJustificationLineActivate
Syntax Access Status
INTEGER {enumeration} read-only optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 2 (left) Success
2 - Set Object to Min. Value 2 (left) Success
3 - Set Object to Max. Value 2 (left) Success
4 - Attempt Write to Read-Only Object   Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max.   Skipped - not writable
7 - Attempt to Set Value < Min.   Skipped - not writable
8 - Restore Object to Original Value   Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-113
VDOT Implemented: Yes
Std Par Ref 5.5.13
OID 1.3.6.1.4.1.1206.4.2.3.4.7.0
Object Name defaultJustificationPage
Syntax Access Status
INTEGER {enumeration} read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 2 (top) Success
2 - Set Object to Min. Value 2 (top) Success
3 - Set Object to Max. Value 2 (top) Success
4 - Attempt Write to Read-Only Object   Skipped - Not read only
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max.   Skipped - no Minimum
7 - Attempt to Set Value < Min.   Skipped - no Minimum
8 - Restore Object to Original Value 2 (top) Success

Overall Test Case Results: Passed

Object Test Case TC-O-114
VDOT Implemented: Yes
Std Par Ref 5.5.14
OID 1.3.6.1.4.1.1206.4.2.3.4.21.0
Object Name defaultJustificationPageActivate
Syntax Access Status
INTEGER {enumeration} read-only optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 2 (top) Success
2 - Set Object to Min. Value 2 (top) Success
3 - Set Object to Max. Value 2 (top) Success
4 - Attempt Write to Read-Only Object   Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max.   Skipped - not writable
7 - Attempt to Set Value < Min.   Skipped - not writable
8 - Restore Object to Original Value   Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-115
VDOT Implemented: Yes
Std Par Ref 5.5.15
OID 1.3.6.1.4.1.1206.4.2.3.4.8.0
Object Name defaultPageOnTime
Syntax Access Status
INTEGER (1..255) read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 50 Success
2 - Set Object to Min. Value 1 Success
3 - Set Object to Max. Value 255 Success
4 - Attempt Write to Read-Only Object   Skipped - Not read only
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 256 Success - did not write greater than Max
7 - Attempt to Set Value < Min. 0 Success - did not write less than Min
8 - Restore Object to Original Value 50 Success

Overall Test Case Results: Passed

Object Test Case TC-O-116
VDOT Implemented: Yes
Std Par Ref 5.5.16
OID 1.3.6.1.4.1.1206.4.2.3.4.22.0
Object Name defaultPageOnTimeActivate
Syntax Access Status
INTEGER (1..255) read-only optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 50 Success
2 - Set Object to Min. Value 1 Success
3 - Set Object to Max. Value 255 Success
4 - Attempt Write to Read-Only Object   Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max.   Skipped - not writable
7 - Attempt to Set Value < Min.   Skipped - not writable
8 - Restore Object to Original Value   Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-117
VDOT Implemented: Yes
Std Par Ref 5.5.17
OID 1.3.6.1.4.1.1206.4.2.3.4.9.0
Object Name defaultPageOffTime
Syntax Access Status
INTEGER (0..255) read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 0 Success
2 - Set Object to Min. Value 0 Success
3 - Set Object to Max. Value 255 Success
4 - Attempt Write to Read-Only Object   Skipped - Not read only
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 256 Success - did not write greater than Max
7 - Attempt to Set Value < Min. -1 Failed - wrote less than Min
8 - Restore Object to Original Value 0 Success

Overall Test Case Results: Passed

Object Test Case TC-O-118
VDOT Implemented: Yes
Std Par Ref 5.5.18
OID 1.3.6.1.4.1.1206.4.2.3.4.23.0
Object Name defaultPageOffTimeActivate
Syntax Access Status
INTEGER (0..255) read-only optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 0 Success
2 - Set Object to Min. Value 0 Success
3 - Set Object to Max. Value 255 Success
4 - Attempt Write to Read-Only Object   Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max.   Skipped - not writable
7 - Attempt to Set Value < Min.   Skipped - not writable
8 - Restore Object to Original Value   Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-119
VDOT Implemented: Yes
Std Par Ref 5.5.19
OID 1.3.6.1.4.1.1206.4.2.3.4.12.0
Object Name defaultBackgroundRGB
Syntax Access Status
OCTET STRING (SIZE (1 | 3)) read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 00 Success
2 - Set Object to Min. Value 00 Success
3 - Set Object to Max. Value 00 Success
4 - Attempt Write to Read-Only Object 00 Skipped - Not read only
5 - Attempt Read of Non-Accessible Object 00 Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 1 Success - did not write greater than Max
7 - Attempt to Set Value < Min. -1 Success - did not write less than Min
8 - Restore Object to Original Value 00 Success

Overall Test Case Results: Passed

Object Test Case TC-O-120
VDOT Implemented: Yes
Std Par Ref 5.5.20
OID 1.3.6.1.4.1.1206.4.2.3.4.24.0
Object Name defaultBackgroundRGBActivate
Syntax Access Status
OCTET STRING (SIZE (1 | 3)) read-only optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 00 Success
2 - Set Object to Min. Value 00 Success
3 - Set Object to Max. Value 00 Success
4 - Attempt Write to Read-Only Object 00 Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object 00 Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 00 Skipped - not writable
7 - Attempt to Set Value < Min. 00 Skipped - not writable
8 - Restore Object to Original Value 00 Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-121
VDOT Implemented: Yes
Std Par Ref 5.5.21
OID 1.3.6.1.4.1.1206.4.2.3.4.13.0
Object Name defaultForegroundRGB
Syntax Access Status
OCTET STRING (SIZE (1 | 3)) read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 09 Success
2 - Set Object to Min. Value 00 Success
3 - Set Object to Max. Value 00 Success
4 - Attempt Write to Read-Only Object 00 Skipped - Not read only
5 - Attempt Read of Non-Accessible Object 00 Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 1 Success - did not write greater than Max
7 - Attempt to Set Value < Min. -1 Success - did not write less than Min
8 - Restore Object to Original Value 09 Success

Overall Test Case Results: Passed

Object Test Case TC-O-122
VDOT Implemented: Yes
Std Par Ref 5.5.22
OID 1.3.6.1.4.1.1206.4.2.3.4.25.0
Object Name defaultForegroundRGBActivate
Syntax Access Status
OCTET STRING (SIZE (1 | 3)) read-only optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 09 Success
2 - Set Object to Min. Value 00 Success
3 - Set Object to Max. Value 00 Success
4 - Attempt Write to Read-Only Object 00 Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object 00 Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 00 Skipped - not writable
7 - Attempt to Set Value < Min. 00 Skipped - not writable
8 - Restore Object to Original Value 00 Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-123
VDOT Implemented: Yes
Std Par Ref 5.5.23
OID 1.3.6.1.4.1.1206.4.2.3.4.10.0
Object Name defaultCharacterSet
Syntax Access Status
INTEGER {enumeration} read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 2 (eightBit) Success
2 - Set Object to Min. Value 2 (eightBit) Success
3 - Set Object to Max. Value 2 (eightBit) Success
4 - Attempt Write to Read-Only Object   Skipped - Not read only
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max.   Skipped - no Minimum
7 - Attempt to Set Value < Min.   Skipped - no Minimum
8 - Restore Object to Original Value 2 (eightBit) Success

Overall Test Case Results: Passed

Object Test Case TC-O-124
VDOT Implemented: Yes
Std Par Ref 5.5.24
OID 1.3.6.1.4.1.1206.4.2.3.4.11.0
Object Name dmsColorScheme
Syntax Access Status
INTEGER {enumeration} read-only optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 3 (colorClassic) Success
2 - Set Object to Min. Value 3 (colorClassic) Success
3 - Set Object to Max. Value 3 (colorClassic) Success
4 - Attempt Write to Read-Only Object   Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max.   Skipped - not writable
7 - Attempt to Set Value < Min.   Skipped - not writable
8 - Restore Object to Original Value   Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-125
VDOT Implemented: Yes
Std Par Ref 5.5.25
OID 1.3.6.1.4.1.1206.4.2.3.4.14.0
Object Name dmsSupportedMultiTags
Syntax Access Status
OCTET STRING read-only optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object FB 7F CF E0 Success
2 - Set Object to Min. Value FB 7F CF E0 Success
3 - Set Object to Max. Value FB 7F CF E0 Success
4 - Attempt Write to Read-Only Object 00 Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object 00 Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 00 Skipped - not writable
7 - Attempt to Set Value < Min. 00 Skipped - not writable
8 - Restore Object to Original Value 00 Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-126
VDOT Implemented: Yes
Std Par Ref 5.6.1
OID 1.3.6.1.4.1.1206.4.2.3.5.1.0
Object Name dmsNumPermanentMsg
Syntax Access Status
INTEGER (0..65535) read-only optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 2 Success
2 - Set Object to Min. Value 2 Success
3 - Set Object to Max. Value 0 Success
4 - Attempt Write to Read-Only Object   Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max.   Skipped - not writable
7 - Attempt to Set Value < Min.   Skipped - not writable
8 - Restore Object to Original Value   Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-127
VDOT Implemented: Yes
Std Par Ref 5.6.2
OID 1.3.6.1.4.1.1206.4.2.3.5.2.0
Object Name dmsNumChangeableMsg
Syntax Access Status
INTEGER (0..65535) read-only optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 2 Success
2 - Set Object to Min. Value 2 Success
3 - Set Object to Max. Value 2 Success
4 - Attempt Write to Read-Only Object   Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max.   Skipped - not writable
7 - Attempt to Set Value < Min.   Skipped - not writable
8 - Restore Object to Original Value   Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-128
VDOT Implemented: Yes
Std Par Ref 5.6.3
OID 1.3.6.1.4.1.1206.4.2.3.5.3.0
Object Name dmsMaxChangeableMsg
Syntax Access Status
INTEGER (0..65535) read-only optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 64 Success
2 - Set Object to Min. Value 64 Success
3 - Set Object to Max. Value 64 Success
4 - Attempt Write to Read-Only Object   Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max.   Skipped - not writable
7 - Attempt to Set Value < Min.   Skipped - not writable
8 - Restore Object to Original Value   Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-129
VDOT Implemented: Yes
Std Par Ref 5.6.4
OID 1.3.6.1.4.1.1206.4.2.3.5.4.0
Object Name dmsFreeChangeableMemory
Syntax Access Status
INTEGER (0..4294967295) read-only optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 31744 Success
2 - Set Object to Min. Value 31744 Success
3 - Set Object to Max. Value 31744 Success
4 - Attempt Write to Read-Only Object   Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max.   Skipped - not writable
7 - Attempt to Set Value < Min.   Skipped - not writable
8 - Restore Object to Original Value   Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-130
VDOT Implemented: Yes
Std Par Ref 5.6.5
OID 1.3.6.1.4.1.1206.4.2.3.5.5.0
Object Name dmsNumVolatileMsg
Syntax Access Status
INTEGER (0..65535) read-only optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 1 Success
2 - Set Object to Min. Value 1 Success
3 - Set Object to Max. Value 1 Success
4 - Attempt Write to Read-Only Object   Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max.   Skipped - not writable
7 - Attempt to Set Value < Min.   Skipped - not writable
8 - Restore Object to Original Value   Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-131
VDOT Implemented: Yes
Std Par Ref 5.6.6
OID 1.3.6.1.4.1.1206.4.2.3.5.6.0
Object Name dmsMaxVolatileMsg
Syntax Access Status
INTEGER (0..65535) read-only optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 64 Success
2 - Set Object to Min. Value 64 Success
3 - Set Object to Max. Value 64 Success
4 - Attempt Write to Read-Only Object   Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max.   Skipped - not writable
7 - Attempt to Set Value < Min.   Skipped - not writable
8 - Restore Object to Original Value   Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-132
VDOT Implemented: Yes
Std Par Ref 5.6.7
OID 1.3.6.1.4.1.1206.4.2.3.5.7.0
Object Name dmsFreeVolatileMemory
Syntax Access Status
INTEGER (0..4294967295) read-only optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 32256 Success
2 - Set Object to Min. Value 32256 Success
3 - Set Object to Max. Value 32256 Success
4 - Attempt Write to Read-Only Object   Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max.   Skipped - not writable
7 - Attempt to Set Value < Min.   Skipped - not writable
8 - Restore Object to Original Value   Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-133
VDOT Implemented: Yes
Std Par Ref 5.6.8.1
OID 1.3.6.1.4.1.1206.4.2.3.5.8.1.1.2.1
Object Name dmsMessageMemoryType
Syntax Access Status
INTEGER {enumeration} read-only optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 2 (permanent) Success
2 - Set Object to Min. Value 2 (permanent) Success
3 - Set Object to Max. Value 2 (permanent) Success
4 - Attempt Write to Read-Only Object   Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max.   Skipped - not writable
7 - Attempt to Set Value < Min.   Skipped - not writable
8 - Restore Object to Original Value   Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-134
VDOT Implemented: Yes
Std Par Ref 5.6.8.1
OID 1.3.6.1.4.1.1206.4.2.3.5.8.1.1.2.2
Object Name dmsMessageMemoryType
Syntax Access Status
INTEGER {enumeration} read-only optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 2 (permanent) Success
2 - Set Object to Min. Value 2 (permanent) Success
3 - Set Object to Max. Value 2 (permanent) Success
4 - Attempt Write to Read-Only Object   Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max.   Skipped - not writable
7 - Attempt to Set Value < Min.   Skipped - not writable
8 - Restore Object to Original Value   Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-135
VDOT Implemented: Yes
Std Par Ref 5.6.8.1
OID 1.3.6.1.4.1.1206.4.2.3.5.8.1.1.3.1
Object Name dmsMessageMemoryType
Syntax Access Status
INTEGER {enumeration} read-only optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 3 (changeable) Success
2 - Set Object to Min. Value 3 (changeable) Success
3 - Set Object to Max. Value 3 (changeable) Success
4 - Attempt Write to Read-Only Object   Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max.   Skipped - not writable
7 - Attempt to Set Value < Min.   Skipped - not writable
8 - Restore Object to Original Value   Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-136
VDOT Implemented: Yes
Std Par Ref 5.6.8.1
OID 1.3.6.1.4.1.1206.4.2.3.5.8.1.1.3.2
Object Name dmsMessageMemoryType
Syntax Access Status
INTEGER {enumeration} read-only optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 3 (changeable) Success
2 - Set Object to Min. Value 3 (changeable) Success
3 - Set Object to Max. Value 3 (changeable) Success
4 - Attempt Write to Read-Only Object   Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max.   Skipped - not writable
7 - Attempt to Set Value < Min.   Skipped - not writable
8 - Restore Object to Original Value   Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-137
VDOT Implemented: Yes
Std Par Ref 5.6.8.1
OID 1.3.6.1.4.1.1206.4.2.3.5.8.1.1.4.1
Object Name dmsMessageMemoryType
Syntax Access Status
INTEGER {enumeration} read-only optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 4 (volatile) Success
2 - Set Object to Min. Value 4 (volatile) Success
3 - Set Object to Max. Value 4 (volatile) Success
4 - Attempt Write to Read-Only Object   Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max.   Skipped - not writable
7 - Attempt to Set Value < Min.   Skipped - not writable
8 - Restore Object to Original Value   Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-138
VDOT Implemented: Yes
Std Par Ref 5.6.8.1
OID 1.3.6.1.4.1.1206.4.2.3.5.8.1.1.4.2
Object Name dmsMessageMemoryType
Syntax Access Status
INTEGER {enumeration} read-only optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 4 (volatile) Success
2 - Set Object to Min. Value 4 (volatile) Success
3 - Set Object to Max. Value 4 (volatile) Success
4 - Attempt Write to Read-Only Object   Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max.   Skipped - not writable
7 - Attempt to Set Value < Min.   Skipped - not writable
8 - Restore Object to Original Value   Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-139
VDOT Implemented: Yes
Std Par Ref 5.6.8.1
OID 1.3.6.1.4.1.1206.4.2.3.5.8.1.1.5.1
Object Name dmsMessageMemoryType
Syntax Access Status
INTEGER {enumeration} read-only optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 5 (currentBuffer) Success
2 - Set Object to Min. Value 5 (currentBuffer) Success
3 - Set Object to Max. Value 5 (currentBuffer) Success
4 - Attempt Write to Read-Only Object   Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max.   Skipped - not writable
7 - Attempt to Set Value < Min.   Skipped - not writable
8 - Restore Object to Original Value   Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-140
VDOT Implemented: Yes
Std Par Ref 5.6.8.1
OID 1.3.6.1.4.1.1206.4.2.3.5.8.1.1.5.2
Object Name dmsMessageMemoryType
Syntax Access Status
INTEGER {enumeration} read-only optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 5 (currentBuffer) Success
2 - Set Object to Min. Value 5 (currentBuffer) Success
3 - Set Object to Max. Value 5 (currentBuffer) Success
4 - Attempt Write to Read-Only Object   Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max.   Skipped - not writable
7 - Attempt to Set Value < Min.   Skipped - not writable
8 - Restore Object to Original Value   Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-141
VDOT Implemented: Yes
Std Par Ref 5.6.8.1
OID 1.3.6.1.4.1.1206.4.2.3.5.8.1.1.6.1
Object Name dmsMessageMemoryType
Syntax Access Status
INTEGER {enumeration} read-only optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 6 (schedule) Success
2 - Set Object to Min. Value 6 (schedule) Success
3 - Set Object to Max. Value 6 (schedule) Success
4 - Attempt Write to Read-Only Object   Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max.   Skipped - not writable
7 - Attempt to Set Value < Min.   Skipped - not writable
8 - Restore Object to Original Value   Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-142
VDOT Implemented: Yes
Std Par Ref 5.6.8.1
OID 1.3.6.1.4.1.1206.4.2.3.5.8.1.1.6.2
Object Name dmsMessageMemoryType
Syntax Access Status
INTEGER {enumeration} read-only optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 6 (schedule) Success
2 - Set Object to Min. Value 6 (schedule) Success
3 - Set Object to Max. Value 6 (schedule) Success
4 - Attempt Write to Read-Only Object   Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max.   Skipped - not writable
7 - Attempt to Set Value < Min.   Skipped - not writable
8 - Restore Object to Original Value   Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-143
VDOT Implemented: Yes
Std Par Ref 5.6.8.2
OID 1.3.6.1.4.1.1206.4.2.3.5.8.1.2.2.1
Object Name dmsMessageNumber
Syntax Access Status
INTEGER (1..65535) read-only optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 1 Success
2 - Set Object to Min. Value 1 Success
3 - Set Object to Max. Value 1 Success
4 - Attempt Write to Read-Only Object   Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max.   Skipped - not writable
7 - Attempt to Set Value < Min.   Skipped - not writable
8 - Restore Object to Original Value   Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-144
VDOT Implemented: Yes
Std Par Ref 5.6.8.2
OID 1.3.6.1.4.1.1206.4.2.3.5.8.1.2.2.2
Object Name dmsMessageNumber
Syntax Access Status
INTEGER (1..65535) read-only optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 2 Success
2 - Set Object to Min. Value 2 Success
3 - Set Object to Max. Value 2 Success
4 - Attempt Write to Read-Only Object   Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max.   Skipped - not writable
7 - Attempt to Set Value < Min.   Skipped - not writable
8 - Restore Object to Original Value   Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-145
VDOT Implemented: Yes
Std Par Ref 5.6.8.2
OID 1.3.6.1.4.1.1206.4.2.3.5.8.1.2.3.1
Object Name dmsMessageNumber
Syntax Access Status
INTEGER (1..65535) read-only optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 1 Success
2 - Set Object to Min. Value 1 Success
3 - Set Object to Max. Value 1 Success
4 - Attempt Write to Read-Only Object   Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max.   Skipped - not writable
7 - Attempt to Set Value < Min.   Skipped - not writable
8 - Restore Object to Original Value   Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-146
VDOT Implemented: Yes
Std Par Ref 5.6.8.2
OID 1.3.6.1.4.1.1206.4.2.3.5.8.1.2.3.2
Object Name dmsMessageNumber
Syntax Access Status
INTEGER (1..65535) read-only optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 2 Success
2 - Set Object to Min. Value 2 Success
3 - Set Object to Max. Value 2 Success
4 - Attempt Write to Read-Only Object   Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max.   Skipped - not writable
7 - Attempt to Set Value < Min.   Skipped - not writable
8 - Restore Object to Original Value   Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-147
VDOT Implemented: Yes
Std Par Ref 5.6.8.2
OID 1.3.6.1.4.1.1206.4.2.3.5.8.1.2.4.1
Object Name dmsMessageNumber
Syntax Access Status
INTEGER (1..65535) read-only optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 1 Success
2 - Set Object to Min. Value 1 Success
3 - Set Object to Max. Value 1 Success
4 - Attempt Write to Read-Only Object   Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max.   Skipped - not writable
7 - Attempt to Set Value < Min.   Skipped - not writable
8 - Restore Object to Original Value   Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-148
VDOT Implemented: Yes
Std Par Ref 5.6.8.2
OID 1.3.6.1.4.1.1206.4.2.3.5.8.1.2.4.2
Object Name dmsMessageNumber
Syntax Access Status
INTEGER (1..65535) read-only optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 2 Success
2 - Set Object to Min. Value 2 Success
3 - Set Object to Max. Value 2 Success
4 - Attempt Write to Read-Only Object   Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max.   Skipped - not writable
7 - Attempt to Set Value < Min.   Skipped - not writable
8 - Restore Object to Original Value   Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-149
VDOT Implemented: Yes
Std Par Ref 5.6.8.2
OID 1.3.6.1.4.1.1206.4.2.3.5.8.1.2.5.1
Object Name dmsMessageNumber
Syntax Access Status
INTEGER (1..65535) read-only optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 1 Success
2 - Set Object to Min. Value 1 Success
3 - Set Object to Max. Value 1 Success
4 - Attempt Write to Read-Only Object   Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max.   Skipped - not writable
7 - Attempt to Set Value < Min.   Skipped - not writable
8 - Restore Object to Original Value   Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-150
VDOT Implemented: Yes
Std Par Ref 5.6.8.2
OID 1.3.6.1.4.1.1206.4.2.3.5.8.1.2.5.2
Object Name dmsMessageNumber
Syntax Access Status
INTEGER (1..65535) read-only optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 2 Success
2 - Set Object to Min. Value 2 Success
3 - Set Object to Max. Value 2 Success
4 - Attempt Write to Read-Only Object   Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max.   Skipped - not writable
7 - Attempt to Set Value < Min.   Skipped - not writable
8 - Restore Object to Original Value   Skipped - Not writable

Overall Test Case Results: Passed

Previous | Table of Contents | Next