Appendix B: Test Cases and Results (continued)

Object Test Case TC-O-151
VDOT Implemented: Yes
Std Par Ref 5.6.8.2
OID 1.3.6.1.4.1.1206.4.2.3.5.8.1.2.6.1
Object Name dmsMessageNumber
Syntax Access Status
INTEGER (1..65535) read-only optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 1 Success
2 - Set Object to Min. Value 1 Success
3 - Set Object to Max. Value 1 Success
4 - Attempt Write to Read-Only Object   Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max.   Skipped - not writable
7 - Attempt to Set Value < Min.   Skipped - not writable
8 - Restore Object to Original Value   Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-152
VDOT Implemented: Yes
Std Par Ref 5.6.8.2
OID 1.3.6.1.4.1.1206.4.2.3.5.8.1.2.6.2
Object Name dmsMessageNumber
Syntax Access Status
INTEGER (1..65535) read-only optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 2 Success
2 - Set Object to Min. Value 2 Success
3 - Set Object to Max. Value 2 Success
4 - Attempt Write to Read-Only Object   Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max.   Skipped - not writable
7 - Attempt to Set Value < Min.   Skipped - not writable
8 - Restore Object to Original Value   Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-153
VDOT Implemented: Yes
Std Par Ref 5.6.8.3
OID 1.3.6.1.4.1.1206.4.2.3.5.8.1.3.2.1
Object Name dmsMessageMultiString
Syntax Access Status
OCTET STRING read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object [jl3]TESTING Success
2 - Set Object to Min. Value [jl3]TESTING Success
3 - Set Object to Max. Value [jl3]TESTING Success
4 - Attempt Write to Read-Only Object 00 Skipped - Not read only
5 - Attempt Read of Non-Accessible Object 00 Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 00 Skipped - no Minimum
7 - Attempt to Set Value < Min. 00 Skipped - no Minimum
8 - Restore Object to Original Value 00 Failed - GenErr

Overall Test Case Results: Passed

Object Test Case TC-O-154
VDOT Implemented: Yes
Std Par Ref 5.6.8.3
OID 1.3.6.1.4.1.1206.4.2.3.5.8.1.3.2.2
Object Name dmsMessageMultiString
Syntax Access Status
OCTET STRING read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object [jl3]PERMANENT[nl]MESSAGE Success
2 - Set Object to Min. Value [jl3]PERMANENT[nl]MESSAGE Success
3 - Set Object to Max. Value [jl3]PERMANENT[nl]MESSAGE Success
4 - Attempt Write to Read-Only Object 00 Skipped - Not read only
5 - Attempt Read of Non-Accessible Object 00 Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 00 Skipped - no Minimum
7 - Attempt to Set Value < Min. 00 Skipped - no Minimum
8 - Restore Object to Original Value 00 Failed - GenErr

Overall Test Case Results: Passed

Object Test Case TC-O-155
VDOT Implemented: Yes
Std Par Ref 5.6.8.3
OID 1.3.6.1.4.1.1206.4.2.3.5.8.1.3.3.1
Object Name dmsMessageMultiString
Syntax Access Status
OCTET STRING read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object TEST MSG Success
2 - Set Object to Min. Value TEST MSG Success
3 - Set Object to Max. Value TEST MSG Success
4 - Attempt Write to Read-Only Object 00 Skipped - Not read only
5 - Attempt Read of Non-Accessible Object 00 Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 00 Skipped - no Minimum
7 - Attempt to Set Value < Min. 00 Skipped - no Minimum
8 - Restore Object to Original Value 00 Failed - GenErr

Overall Test Case Results: Passed

Object Test Case TC-O-156
VDOT Implemented: Yes
Std Par Ref 5.6.8.3
OID 1.3.6.1.4.1.1206.4.2.3.5.8.1.3.3.2
Object Name dmsMessageMultiString
Syntax Access Status
OCTET STRING read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object [jp3][jl3]DYNAMIC[nl2][jl2]MESSAGE[nl2][jl3]TESTING1231 Success
2 - Set Object to Min. Value [jp3][jl3]DYNAMIC[nl2][jl2]MESSAGE[nl2][jl3]TESTING1231 Success
3 - Set Object to Max. Value [jp3][jl3]DYNAMIC[nl2][jl2]MESSAGE[nl2][jl3]TESTING1231 Success
4 - Attempt Write to Read-Only Object 00 Skipped - Not read only
5 - Attempt Read of Non-Accessible Object 00 Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 00 Skipped - no Minimum
7 - Attempt to Set Value < Min. 00 Skipped - no Minimum
8 - Restore Object to Original Value 00 Failed - GenErr

Overall Test Case Results: Passed

Object Test Case TC-O-157
VDOT Implemented: Yes
Std Par Ref 5.6.8.3
OID 1.3.6.1.4.1.1206.4.2.3.5.8.1.3.4.1
Object Name dmsMessageMultiString
Syntax Access Status
OCTET STRING read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object VOLATILE[nl]MESSAGE Success
2 - Set Object to Min. Value VOLATILE[nl]MESSAGE Success
3 - Set Object to Max. Value VOLATILE[nl]MESSAGE Success
4 - Attempt Write to Read-Only Object 00 Skipped - Not read only
5 - Attempt Read of Non-Accessible Object 00 Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 00 Skipped - no Minimum
7 - Attempt to Set Value < Min. 00 Skipped - no Minimum
8 - Restore Object to Original Value 00 Failed - GenErr

Overall Test Case Results: Passed

Object Test Case TC-O-158
VDOT Implemented: Yes
Std Par Ref 5.6.8.3
OID 1.3.6.1.4.1.1206.4.2.3.5.8.1.3.4.2
Object Name dmsMessageMultiString
Syntax Access Status
OCTET STRING read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object   Success
2 - Set Object to Min. Value   Success
3 - Set Object to Max. Value   Success
4 - Attempt Write to Read-Only Object 00 Skipped - Not read only
5 - Attempt Read of Non-Accessible Object 00 Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 00 Skipped - no Minimum
7 - Attempt to Set Value < Min. 00 Skipped - no Minimum
8 - Restore Object to Original Value 00 Failed - GenErr

Overall Test Case Results: Passed

Object Test Case TC-O-159
VDOT Implemented: Yes
Std Par Ref 5.6.8.3
OID 1.3.6.1.4.1.1206.4.2.3.5.8.1.3.5.1
Object Name dmsMessageMultiString
Syntax Access Status
OCTET STRING read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object   Success
2 - Set Object to Min. Value   Success
3 - Set Object to Max. Value   Success
4 - Attempt Write to Read-Only Object 00 Skipped - Not read only
5 - Attempt Read of Non-Accessible Object 00 Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 00 Skipped - no Minimum
7 - Attempt to Set Value < Min. 00 Skipped - no Minimum
8 - Restore Object to Original Value 00 Failed - GenErr

Overall Test Case Results: Passed

Object Test Case TC-O-160
VDOT Implemented: Yes
Std Par Ref 5.6.8.3
OID 1.3.6.1.4.1.1206.4.2.3.5.8.1.3.5.2
Object Name dmsMessageMultiString
Syntax Access Status
OCTET STRING read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object   Success
2 - Set Object to Min. Value   Success
3 - Set Object to Max. Value   Success
4 - Attempt Write to Read-Only Object 00 Skipped - Not read only
5 - Attempt Read of Non-Accessible Object 00 Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 00 Skipped - no Minimum
7 - Attempt to Set Value < Min. 00 Skipped - no Minimum
8 - Restore Object to Original Value 00 Failed - GenErr

Overall Test Case Results: Passed

Object Test Case TC-O-161
VDOT Implemented: Yes
Std Par Ref 5.6.8.3
OID 1.3.6.1.4.1.1206.4.2.3.5.8.1.3.6.1
Object Name dmsMessageMultiString
Syntax Access Status
OCTET STRING read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object   Success
2 - Set Object to Min. Value   Success
3 - Set Object to Max. Value   Success
4 - Attempt Write to Read-Only Object 00 Skipped - Not read only
5 - Attempt Read of Non-Accessible Object 00 Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 00 Skipped - no Minimum
7 - Attempt to Set Value < Min. 00 Skipped - no Minimum
8 - Restore Object to Original Value 00 Failed - GenErr

Overall Test Case Results: Passed

Object Test Case TC-O-162
VDOT Implemented: Yes
Std Par Ref 5.6.8.3
OID 1.3.6.1.4.1.1206.4.2.3.5.8.1.3.6.2
Object Name dmsMessageMultiString
Syntax Access Status
OCTET STRING read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object   Success
2 - Set Object to Min. Value   Success
3 - Set Object to Max. Value   Success
4 - Attempt Write to Read-Only Object 00 Skipped - Not read only
5 - Attempt Read of Non-Accessible Object 00 Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 00 Skipped - no Minimum
7 - Attempt to Set Value < Min. 00 Skipped - no Minimum
8 - Restore Object to Original Value 00 Failed - GenErr

Overall Test Case Results: Passed

Object Test Case TC-O-163
VDOT Implemented: Yes
Std Par Ref 5.6.8.4
OID 1.3.6.1.4.1.1206.4.2.3.5.8.1.4.2.1
Object Name dmsMessageOwner
Syntax Access Status
OwnerString read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object   Success
2 - Set Object to Min. Value   Success
3 - Set Object to Max. Value   Success
4 - Attempt Write to Read-Only Object 00 Skipped - Not read only
5 - Attempt Read of Non-Accessible Object 00 Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 00 Skipped - no Minimum
7 - Attempt to Set Value < Min. 00 Skipped - no Minimum
8 - Restore Object to Original Value 00 Failed - GenErr

Overall Test Case Results: Passed

Object Test Case TC-O-164
VDOT Implemented: Yes
Std Par Ref 5.6.8.4
OID 1.3.6.1.4.1.1206.4.2.3.5.8.1.4.2.2
Object Name dmsMessageOwner
Syntax Access Status
OwnerString read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object   Success
2 - Set Object to Min. Value   Success
3 - Set Object to Max. Value   Success
4 - Attempt Write to Read-Only Object 00 Skipped - Not read only
5 - Attempt Read of Non-Accessible Object 00 Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 00 Skipped - no Minimum
7 - Attempt to Set Value < Min. 00 Skipped - no Minimum
8 - Restore Object to Original Value 00 Failed - GenErr

Overall Test Case Results: Passed

Object Test Case TC-O-165
VDOT Implemented: Yes
Std Par Ref 5.6.8.4
OID 1.3.6.1.4.1.1206.4.2.3.5.8.1.4.3.1
Object Name dmsMessageOwner
Syntax Access Status
OwnerString read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object battelle Success
2 - Set Object to Min. Value battelle Success
3 - Set Object to Max. Value battelle Success
4 - Attempt Write to Read-Only Object 00 Skipped - Not read only
5 - Attempt Read of Non-Accessible Object 00 Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 00 Skipped - no Minimum
7 - Attempt to Set Value < Min. 00 Skipped - no Minimum
8 - Restore Object to Original Value 00 Failed - GenErr

Overall Test Case Results: Passed

Object Test Case TC-O-166
VDOT Implemented: Yes
Std Par Ref 5.6.8.4
OID 1.3.6.1.4.1.1206.4.2.3.5.8.1.4.3.2
Object Name dmsMessageOwner
Syntax Access Status
OwnerString read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object   Success
2 - Set Object to Min. Value   Success
3 - Set Object to Max. Value   Success
4 - Attempt Write to Read-Only Object 00 Skipped - Not read only
5 - Attempt Read of Non-Accessible Object 00 Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 00 Skipped - no Minimum
7 - Attempt to Set Value < Min. 00 Skipped - no Minimum
8 - Restore Object to Original Value 00 Failed - GenErr

Overall Test Case Results: Passed

Object Test Case TC-O-167
VDOT Implemented: Yes
Std Par Ref 5.6.8.4
OID 1.3.6.1.4.1.1206.4.2.3.5.8.1.4.4.1
Object Name dmsMessageOwner
Syntax Access Status
OwnerString read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object ISTT Success
2 - Set Object to Min. Value ISTT Success
3 - Set Object to Max. Value ISTT Success
4 - Attempt Write to Read-Only Object 00 Skipped - Not read only
5 - Attempt Read of Non-Accessible Object 00 Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 00 Skipped - no Minimum
7 - Attempt to Set Value < Min. 00 Skipped - no Minimum
8 - Restore Object to Original Value 00 Failed - GenErr

Overall Test Case Results: Passed

Object Test Case TC-O-168
VDOT Implemented: Yes
Std Par Ref 5.6.8.4
OID 1.3.6.1.4.1.1206.4.2.3.5.8.1.4.4.2
Object Name dmsMessageOwner
Syntax Access Status
OwnerString read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object   Success
2 - Set Object to Min. Value   Success
3 - Set Object to Max. Value   Success
4 - Attempt Write to Read-Only Object 00 Skipped - Not read only
5 - Attempt Read of Non-Accessible Object 00 Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 00 Skipped - no Minimum
7 - Attempt to Set Value < Min. 00 Skipped - no Minimum
8 - Restore Object to Original Value 00 Failed - GenErr

Overall Test Case Results: Passed

Object Test Case TC-O-169
VDOT Implemented: Yes
Std Par Ref 5.6.8.4
OID 1.3.6.1.4.1.1206.4.2.3.5.8.1.4.5.1
Object Name dmsMessageOwner
Syntax Access Status
OwnerString read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object   Success
2 - Set Object to Min. Value   Success
3 - Set Object to Max. Value   Success
4 - Attempt Write to Read-Only Object 00 Skipped - Not read only
5 - Attempt Read of Non-Accessible Object 00 Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 00 Skipped - no Minimum
7 - Attempt to Set Value < Min. 00 Skipped - no Minimum
8 - Restore Object to Original Value 00 Failed - GenErr

Overall Test Case Results: Passed

Object Test Case TC-O-170
VDOT Implemented: Yes
Std Par Ref 5.6.8.4
OID 1.3.6.1.4.1.1206.4.2.3.5.8.1.4.5.2
Object Name dmsMessageOwner
Syntax Access Status
OwnerString read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object   Success
2 - Set Object to Min. Value   Success
3 - Set Object to Max. Value   Success
4 - Attempt Write to Read-Only Object 00 Skipped - Not read only
5 - Attempt Read of Non-Accessible Object 00 Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 00 Skipped - no Minimum
7 - Attempt to Set Value < Min. 00 Skipped - no Minimum
8 - Restore Object to Original Value 00 Failed - GenErr

Overall Test Case Results: Passed

Object Test Case TC-O-171
VDOT Implemented: Yes
Std Par Ref 5.6.8.4
OID 1.3.6.1.4.1.1206.4.2.3.5.8.1.4.6.1
Object Name dmsMessageOwner
Syntax Access Status
OwnerString read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object   Success
2 - Set Object to Min. Value   Success
3 - Set Object to Max. Value   Success
4 - Attempt Write to Read-Only Object 00 Skipped - Not read only
5 - Attempt Read of Non-Accessible Object 00 Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 00 Skipped - no Minimum
7 - Attempt to Set Value < Min. 00 Skipped - no Minimum
8 - Restore Object to Original Value 00 Failed - GenErr

Overall Test Case Results: Passed

Object Test Case TC-O-172
VDOT Implemented: Yes
Std Par Ref 5.6.8.4
OID 1.3.6.1.4.1.1206.4.2.3.5.8.1.4.6.2
Object Name dmsMessageOwner
Syntax Access Status
OwnerString read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object   Success
2 - Set Object to Min. Value   Success
3 - Set Object to Max. Value   Success
4 - Attempt Write to Read-Only Object 00 Skipped - Not read only
5 - Attempt Read of Non-Accessible Object 00 Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 00 Skipped - no Minimum
7 - Attempt to Set Value < Min. 00 Skipped - no Minimum
8 - Restore Object to Original Value 00 Failed - GenErr

Overall Test Case Results: Passed

Object Test Case TC-O-173
VDOT Implemented: Yes
Std Par Ref 5.6.8.5
OID 1.3.6.1.4.1.1206.4.2.3.5.8.1.5.2.1
Object Name dmsMessageCRC
Syntax Access Status
INTEGER (0..65535) read-only optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 61236 Success
2 - Set Object to Min. Value 61236 Success
3 - Set Object to Max. Value 0 Success
4 - Attempt Write to Read-Only Object   Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
7 - Attempt to Set Value < Min..   Skipped - not writable
6 - Attempt to Set Value > Max   Skipped - not writable
8 - Restore Object to Original Value   Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-174
VDOT Implemented: Yes
Std Par Ref 5.6.8.5
OID 1.3.6.1.4.1.1206.4.2.3.5.8.1.5.2.2
Object Name dmsMessageCRC
Syntax Access Status
INTEGER (0..65535) read-only optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 4346 Success
2 - Set Object to Min. Value 4346 Success
3 - Set Object to Max. Value 0 Success
4 - Attempt Write to Read-Only Object   Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max.   Skipped - not writable
7 - Attempt to Set Value < Min.   Skipped - not writable
8 - Restore Object to Original Value   Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-175
VDOT Implemented: Yes
Std Par Ref 5.6.8.5
OID 1.3.6.1.4.1.1206.4.2.3.5.8.1.5.3.1
Object Name dmsMessageCRC
Syntax Access Status
INTEGER (0..65535) read-only optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 51247 Success
2 - Set Object to Min. Value 51247 Success
3 - Set Object to Max. Value 51247 Success
4 - Attempt Write to Read-Only Object   Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max.   Skipped - not writable
7 - Attempt to Set Value < Min.   Skipped - not writable
8 - Restore Object to Original Value   Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-176
VDOT Implemented: Yes
Std Par Ref 5.6.8.5
OID 1.3.6.1.4.1.1206.4.2.3.5.8.1.5.3.2
Object Name dmsMessageCRC
Syntax Access Status
INTEGER (0..65535) read-only optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 27735 Success
2 - Set Object to Min. Value 27735 Success
3 - Set Object to Max. Value 27735 Success
4 - Attempt Write to Read-Only Object   Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max.   Skipped - not writable
7 - Attempt to Set Value < Min.   Skipped - not writable
8 - Restore Object to Original Value   Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-177
VDOT Implemented: Yes
Std Par Ref 5.6.8.5
OID 1.3.6.1.4.1.1206.4.2.3.5.8.1.5.4.1
Object Name dmsMessageCRC
Syntax Access Status
INTEGER (0..65535) read-only optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 19307 Success
2 - Set Object to Min. Value 19307 Success
3 - Set Object to Max. Value 19307 Success
4 - Attempt Write to Read-Only Object   Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max.   Skipped - not writable
7 - Attempt to Set Value < Min.   Skipped - not writable
8 - Restore Object to Original Value   Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-178
VDOT Implemented: Yes
Std Par Ref 5.6.8.5
OID 1.3.6.1.4.1.1206.4.2.3.5.8.1.5.4.2
Object Name dmsMessageCRC
Syntax Access Status
INTEGER (0..65535) read-only optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 0 Success
2 - Set Object to Min. Value 0 Success
3 - Set Object to Max. Value 0 Success
4 - Attempt Write to Read-Only Object   Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max.   Skipped - not writable
7 - Attempt to Set Value < Min.   Skipped - not writable
8 - Restore Object to Original Value   Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-179
VDOT Implemented: Yes
Std Par Ref 5.6.8.5
OID 1.3.6.1.4.1.1206.4.2.3.5.8.1.5.5.1
Object Name dmsMessageCRC
Syntax Access Status
INTEGER (0..65535) read-only optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 0 Success
2 - Set Object to Min. Value 0 Success
3 - Set Object to Max. Value 0 Success
4 - Attempt Write to Read-Only Object   Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max.   Skipped - not writable
7 - Attempt to Set Value < Min.   Skipped - not writable
8 - Restore Object to Original Value   Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-180
VDOT Implemented: Yes
Std Par Ref 5.6.8.5
OID 1.3.6.1.4.1.1206.4.2.3.5.8.1.5.5.2
Object Name dmsMessageCRC
Syntax Access Status
INTEGER (0..65535) read-only optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 0 Success
2 - Set Object to Min. Value 0 Success
3 - Set Object to Max. Value 0 Success
4 - Attempt Write to Read-Only Object   Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max.   Skipped - not writable
7 - Attempt to Set Value < Min.   Skipped - not writable
8 - Restore Object to Original Value   Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-181
VDOT Implemented: Yes
Std Par Ref 5.6.8.5
OID 1.3.6.1.4.1.1206.4.2.3.5.8.1.5.6.1
Object Name dmsMessageCRC
Syntax Access Status
INTEGER (0..65535) read-only optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 18191 Success
2 - Set Object to Min. Value 18191 Success
3 - Set Object to Max. Value 18191 Success
4 - Attempt Write to Read-Only Object   Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max.   Skipped - not writable
7 - Attempt to Set Value < Min.   Skipped - not writable
8 - Restore Object to Original Value   Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-182
VDOT Implemented: Yes
Std Par Ref 5.6.8.5
OID 1.3.6.1.4.1.1206.4.2.3.5.8.1.5.6.2
Object Name dmsMessageCRC
Syntax Access Status
INTEGER (0..65535) read-only optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 0 Success
2 - Set Object to Min. Value 0 Success
3 - Set Object to Max. Value 0 Success
4 - Attempt Write to Read-Only Object   Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max.   Skipped - not writable
7 - Attempt to Set Value < Min.   Skipped - not writable
8 - Restore Object to Original Value   Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-183
VDOT Implemented: Yes
Std Par Ref 5.6.8.6
OID 1.3.6.1.4.1.1206.4.2.3.5.8.1.6.2.1
Object Name dmsMessageBeacon
Syntax Access Status
INTEGER (0..1) read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 0 Success
2 - Set Object to Min. Value 0 Success
3 - Set Object to Max. Value 0 Success
4 - Attempt Write to Read-Only Object   Skipped - Not read only
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 2 Success - did not write greater than Max
7 - Attempt to Set Value < Min. -1 Success - did not write less than Min
8 - Restore Object to Original Value   Failed - GenErr

Overall Test Case Results: Passed

Object Test Case TC-O-184
VDOT Implemented: Yes
Std Par Ref 5.6.8.6
OID 1.3.6.1.4.1.1206.4.2.3.5.8.1.6.2.2
Object Name dmsMessageBeacon
Syntax Access Status
INTEGER (0..1) read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 0 Success
2 - Set Object to Min. Value 0 Success
3 - Set Object to Max. Value 0 Success
4 - Attempt Write to Read-Only Object   Skipped - Not read only
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 2 Success - did not write greater than Max
7 - Attempt to Set Value < Min. -1 Success - did not write less than Min
8 - Restore Object to Original Value   Failed - GenErr

Overall Test Case Results: Passed

Object Test Case TC-O-185
VDOT Implemented: Yes
Std Par Ref 5.6.8.6
OID 1.3.6.1.4.1.1206.4.2.3.5.8.1.6.3.1
Object Name dmsMessageBeacon
Syntax Access Status
INTEGER (0..1) read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 0 Success
2 - Set Object to Min. Value 0 Success
3 - Set Object to Max. Value 0 Success
4 - Attempt Write to Read-Only Object   Skipped - Not read only
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 2 Success - did not write greater than Max
7 - Attempt to Set Value < Min. -1 Success - did not write less than Min
8 - Restore Object to Original Value   Failed - GenErr

Overall Test Case Results: Passed

Object Test Case TC-O-186
VDOT Implemented: Yes
Std Par Ref 5.6.8.6
OID 1.3.6.1.4.1.1206.4.2.3.5.8.1.6.3.2
Object Name dmsMessageBeacon
Syntax Access Status
INTEGER (0..1) read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 0 Success
2 - Set Object to Min. Value 0 Success
3 - Set Object to Max. Value 0 Success
4 - Attempt Write to Read-Only Object   Skipped - Not read only
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 2 Success - did not write greater than Max
7 - Attempt to Set Value < Min. -1 Success - did not write less than Min
8 - Restore Object to Original Value   Failed - GenErr

Overall Test Case Results: Passed

Object Test Case TC-O-187
VDOT Implemented: Yes
Std Par Ref 5.6.8.6
OID 1.3.6.1.4.1.1206.4.2.3.5.8.1.6.4.1
Object Name dmsMessageBeacon
Syntax Access Status
INTEGER (0..1) read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 0 Success
2 - Set Object to Min. Value 0 Success
3 - Set Object to Max. Value 0 Success
4 - Attempt Write to Read-Only Object   Skipped - Not read only
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 2 Success - did not write greater than Max
7 - Attempt to Set Value < Min. -1 Success - did not write less than Min
8 - Restore Object to Original Value   Failed - GenErr

Overall Test Case Results: Passed

Object Test Case TC-O-188
VDOT Implemented: Yes
Std Par Ref 5.6.8.6
OID 1.3.6.1.4.1.1206.4.2.3.5.8.1.6.4.2
Object Name dmsMessageBeacon
Syntax Access Status
INTEGER (0..1) read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 0 Success
2 - Set Object to Min. Value 0 Success
3 - Set Object to Max. Value 0 Success
4 - Attempt Write to Read-Only Object   Skipped - Not read only
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 2 Success - did not write greater than Max
7 - Attempt to Set Value < Min. -1 Success - did not write less than Min
8 - Restore Object to Original Value   Failed - GenErr

Overall Test Case Results: Passed

Object Test Case TC-O-189
VDOT Implemented: Yes
Std Par Ref 5.6.8.6
OID 1.3.6.1.4.1.1206.4.2.3.5.8.1.6.5.1
Object Name dmsMessageBeacon
Syntax Access Status
INTEGER (0..1) read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 0 Success
2 - Set Object to Min. Value 0 Success
3 - Set Object to Max. Value 0 Success
4 - Attempt Write to Read-Only Object   Skipped - Not read only
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 2 Success - did not write greater than Max
7 - Attempt to Set Value < Min. -1 Success - did not write less than Min
8 - Restore Object to Original Value   Failed - GenErr

Overall Test Case Results: Passed

Object Test Case TC-O-190
VDOT Implemented: Yes
Std Par Ref 5.6.8.6
OID 1.3.6.1.4.1.1206.4.2.3.5.8.1.6.5.2
Object Name dmsMessageBeacon
Syntax Access Status
INTEGER (0..1) read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 0 Success
2 - Set Object to Min. Value 0 Success
3 - Set Object to Max. Value 0 Success
4 - Attempt Write to Read-Only Object   Skipped - Not read only
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 2 Success - did not write greater than Max
7 - Attempt to Set Value < Min. -1 Success - did not write less than Min
8 - Restore Object to Original Value   Failed - GenErr

Overall Test Case Results: Passed

Object Test Case TC-O-191
VDOT Implemented: Yes
Std Par Ref 5.6.8.6
OID 1.3.6.1.4.1.1206.4.2.3.5.8.1.6.6.1
Object Name dmsMessageBeacon
Syntax Access Status
INTEGER (0..1) read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 0 Success
2 - Set Object to Min. Value 0 Success
3 - Set Object to Max. Value 0 Success
4 - Attempt Write to Read-Only Object   Skipped - Not read only
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 2 Success - did not write greater than Max
7 - Attempt to Set Value < Min. -1 Success - did not write less than Min
8 - Restore Object to Original Value   Failed - GenErr

Overall Test Case Results: Passed

Object Test Case TC-O-192
VDOT Implemented: Yes
Std Par Ref 5.6.8.6
OID 1.3.6.1.4.1.1206.4.2.3.5.8.1.6.6.2
Object Name dmsMessageBeacon
Syntax Access Status
INTEGER (0..1) read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 0 Success
2 - Set Object to Min. Value 0 Success
3 - Set Object to Max. Value 0 Success
4 - Attempt Write to Read-Only Object   Skipped - Not read only
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 2 Success - did not write greater than Max
7 - Attempt to Set Value < Min. -1 Success - did not write less than Min
8 - Restore Object to Original Value   Failed - GenErr

Overall Test Case Results: Passed

Object Test Case TC-O-193
VDOT Implemented: Yes
Std Par Ref 5.6.8.7
OID 1.3.6.1.4.1.1206.4.2.3.5.8.1.7.2.1
Object Name dmsMessagePixelService
Syntax Access Status
INTEGER (0..1) read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 0 Success
2 - Set Object to Min. Value 0 Success
3 - Set Object to Max. Value 0 Success
4 - Attempt Write to Read-Only Object   Skipped - Not read only
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 2 Success - did not write greater than Max
7 - Attempt to Set Value < Min. -1 Success - did not write less than Min
8 - Restore Object to Original Value   Failed - GenErr

Overall Test Case Results: Passed

Object Test Case TC-O-194
VDOT Implemented: Yes
Std Par Ref 5.6.8.7
OID 1.3.6.1.4.1.1206.4.2.3.5.8.1.7.2.2
Object Name dmsMessagePixelService
Syntax Access Status
INTEGER (0..1) read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 0 Success
2 - Set Object to Min. Value 0 Success
3 - Set Object to Max. Value 0 Success
4 - Attempt Write to Read-Only Object   Skipped - Not read only
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 2 Success - did not write greater than Max
7 - Attempt to Set Value < Min. -1 Success - did not write less than Min
8 - Restore Object to Original Value   Failed - GenErr

Overall Test Case Results: Passed

Object Test Case TC-O-195
VDOT Implemented: Yes
Std Par Ref 5.6.8.7
OID 1.3.6.1.4.1.1206.4.2.3.5.8.1.7.3.1
Object Name dmsMessagePixelService
Syntax Access Status
INTEGER (0..1) read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 0 Success
2 - Set Object to Min. Value 0 Success
3 - Set Object to Max. Value 0 Success
4 - Attempt Write to Read-Only Object   Skipped - Not read only
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 2 Success - did not write greater than Max
7 - Attempt to Set Value < Min. -1 Success - did not write less than Min
8 - Restore Object to Original Value   Failed - GenErr

Overall Test Case Results: Passed

Object Test Case TC-O-196
VDOT Implemented: Yes
Std Par Ref 5.6.8.7
OID 1.3.6.1.4.1.1206.4.2.3.5.8.1.7.3.2
Object Name dmsMessagePixelService
Syntax Access Status
INTEGER (0..1) read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 0 Success
2 - Set Object to Min. Value 0 Success
3 - Set Object to Max. Value 0 Success
4 - Attempt Write to Read-Only Object   Skipped - Not read only
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 2 Success - did not write greater than Max
7 - Attempt to Set Value < Min. -1 Success - did not write less than Min
8 - Restore Object to Original Value   Failed - GenErr

Overall Test Case Results: Passed

Object Test Case TC-O-197
VDOT Implemented: Yes
Std Par Ref 5.6.8.7
OID 1.3.6.1.4.1.1206.4.2.3.5.8.1.7.4.1
Object Name dmsMessagePixelService
Syntax Access Status
INTEGER (0..1) read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 0 Success
2 - Set Object to Min. Value 0 Success
3 - Set Object to Max. Value 0 Success
4 - Attempt Write to Read-Only Object   Skipped - Not read only
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 2 Success - did not write greater than Max
7 - Attempt to Set Value < Min. -1 Success - did not write less than Min
8 - Restore Object to Original Value   Failed - GenErr

Overall Test Case Results: Passed

Object Test Case TC-O-198
VDOT Implemented: Yes
Std Par Ref 5.6.8.7
OID 1.3.6.1.4.1.1206.4.2.3.5.8.1.7.4.2
Object Name dmsMessagePixelService
Syntax Access Status
INTEGER (0..1) read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 0 Success
2 - Set Object to Min. Value 0 Success
3 - Set Object to Max. Value 0 Success
4 - Attempt Write to Read-Only Object   Skipped - Not read only
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 2 Success - did not write greater than Max
7 - Attempt to Set Value < Min. -1 Success - did not write less than Min
8 - Restore Object to Original Value   Failed - GenErr

Overall Test Case Results: Passed

Object Test Case TC-O-199
VDOT Implemented: Yes
Std Par Ref 5.6.8.7
OID 1.3.6.1.4.1.1206.4.2.3.5.8.1.7.5.1
Object Name dmsMessagePixelService
Syntax Access Status
INTEGER (0..1) read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 0 Success
2 - Set Object to Min. Value 0 Success
3 - Set Object to Max. Value 0 Success
4 - Attempt Write to Read-Only Object   Skipped - Not read only
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 2 Success - did not write greater than Max
7 - Attempt to Set Value < Min. -1 Success - did not write less than Min
8 - Restore Object to Original Value   Failed - GenErr

Overall Test Case Results: Passed

Object Test Case TC-O-200
VDOT Implemented: Yes
Std Par Ref 5.6.8.7
OID 1.3.6.1.4.1.1206.4.2.3.5.8.1.7.5.2
Object Name dmsMessagePixelService
Syntax Access Status
INTEGER (0..1) read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 0 Success
2 - Set Object to Min. Value 0 Success
3 - Set Object to Max. Value 0 Success
4 - Attempt Write to Read-Only Object   Skipped - Not read only
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 2 Success - did not write greater than Max
7 - Attempt to Set Value < Min. -1 Success - did not write less than Min
8 - Restore Object to Original Value   Failed - GenErr

Overall Test Case Results: Passed

Object Test Case TC-O-201
VDOT Implemented: Yes
Std Par Ref 5.6.8.7
OID 1.3.6.1.4.1.1206.4.2.3.5.8.1.7.6.1
Object Name dmsMessagePixelService
Syntax Access Status
INTEGER (0..1) read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 0 Success
2 - Set Object to Min. Value 0 Success
3 - Set Object to Max. Value 0 Success
4 - Attempt Write to Read-Only Object   Skipped - Not read only
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 2 Success - did not write greater than Max
7 - Attempt to Set Value < Min. -1 Success - did not write less than Min
8 - Restore Object to Original Value   Failed - GenErr

Overall Test Case Results: Passed

Object Test Case TC-O-202
VDOT Implemented: Yes
Std Par Ref 5.6.8.7
OID 1.3.6.1.4.1.1206.4.2.3.5.8.1.7.6.2
Object Name dmsMessagePixelService
Syntax Access Status
INTEGER (0..1) read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 0 Success
2 - Set Object to Min. Value 0 Success
3 - Set Object to Max. Value 0 Success
4 - Attempt Write to Read-Only Object   Skipped - Not read only
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 2 Success - did not write greater than Max
7 - Attempt to Set Value < Min. -1 Success - did not write less than Min
8 - Restore Object to Original Value   Failed - GenErr

Overall Test Case Results: Passed

Object Test Case TC-O-203
VDOT Implemented: Yes
Std Par Ref 5.6.8.8
OID 1.3.6.1.4.1.1206.4.2.3.5.8.1.8.2.1
Object Name dmsMessageRunTimePriority
Syntax Access Status
INTEGER (1..255) read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 1 Success
2 - Set Object to Min. Value 1 Success
3 - Set Object to Max. Value 1 Success
4 - Attempt Write to Read-Only Object   Skipped - Not read only
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 256 Success - did not write greater than Max
7 - Attempt to Set Value < Min. 0 Success - did not write less than Min
8 - Restore Object to Original Value   Failed - GenErr

Overall Test Case Results: Passed

Object Test Case TC-O-204
VDOT Implemented: Yes
Std Par Ref 5.6.8.8
OID 1.3.6.1.4.1.1206.4.2.3.5.8.1.8.2.2
Object Name dmsMessageRunTimePriority
Syntax Access Status
INTEGER (1..255) read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 1 Success
2 - Set Object to Min. Value 1 Success
3 - Set Object to Max. Value 1 Success
4 - Attempt Write to Read-Only Object   Skipped - Not read only
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 256 Success - did not write greater than Max
7 - Attempt to Set Value < Min. 0 Success - did not write less than Min
8 - Restore Object to Original Value   Failed - GenErr

Overall Test Case Results: Passed

Object Test Case TC-O-205
VDOT Implemented: Yes
Std Par Ref 5.6.8.8
OID 1.3.6.1.4.1.1206.4.2.3.5.8.1.8.3.1
Object Name dmsMessageRunTimePriority
Syntax Access Status
INTEGER (1..255) read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 1 Success
2 - Set Object to Min. Value 1 Success
3 - Set Object to Max. Value 1 Success
4 - Attempt Write to Read-Only Object   Skipped - Not read only
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 256 Success - did not write greater than Max
7 - Attempt to Set Value < Min. 0 Success - did not write less than Min
8 - Restore Object to Original Value   Failed - GenErr

Overall Test Case Results: Passed

Object Test Case TC-O-206
VDOT Implemented: Yes
Std Par Ref 5.6.8.8
OID 1.3.6.1.4.1.1206.4.2.3.5.8.1.8.3.2
Object Name dmsMessageRunTimePriority
Syntax Access Status
INTEGER (1..255) read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 1 Success
2 - Set Object to Min. Value 1 Success
3 - Set Object to Max. Value 1 Success
4 - Attempt Write to Read-Only Object   Skipped - Not read only
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 256 Success - did not write greater than Max
7 - Attempt to Set Value < Min. 0 Success - did not write less than Min
8 - Restore Object to Original Value   Failed - GenErr

Overall Test Case Results: Passed

Object Test Case TC-O-207
VDOT Implemented: Yes
Std Par Ref 5.6.8.8
OID 1.3.6.1.4.1.1206.4.2.3.5.8.1.8.4.1
Object Name dmsMessageRunTimePriority
Syntax Access Status
INTEGER (1..255) read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 14 Success
2 - Set Object to Min. Value 14 Success
3 - Set Object to Max. Value 14 Success
4 - Attempt Write to Read-Only Object   Skipped - Not read only
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 256 Success - did not write greater than Max
7 - Attempt to Set Value < Min. 0 Success - did not write less than Min
8 - Restore Object to Original Value   Failed - GenErr

Overall Test Case Results: Passed

Object Test Case TC-O-208
VDOT Implemented: Yes
Std Par Ref 5.6.8.8
OID 1.3.6.1.4.1.1206.4.2.3.5.8.1.8.4.2
Object Name dmsMessageRunTimePriority
Syntax Access Status
INTEGER (1..255) read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 1 Success
2 - Set Object to Min. Value 1 Success
3 - Set Object to Max. Value 1 Success
4 - Attempt Write to Read-Only Object   Skipped - Not read only
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 256 Success - did not write greater than Max
7 - Attempt to Set Value < Min. 0 Success - did not write less than Min
8 - Restore Object to Original Value   Failed - GenErr

Overall Test Case Results: Passed

Object Test Case TC-O-209
VDOT Implemented: Yes
Std Par Ref 5.6.8.8
OID 1.3.6.1.4.1.1206.4.2.3.5.8.1.8.5.1
Object Name dmsMessageRunTimePriority
Syntax Access Status
INTEGER (1..255) read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 1 Success
2 - Set Object to Min. Value 1 Success
3 - Set Object to Max. Value 1 Success
4 - Attempt Write to Read-Only Object   Skipped - Not read only
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 256 Success - did not write greater than Max
7 - Attempt to Set Value < Min. 0 Success - did not write less than Min
8 - Restore Object to Original Value   Failed - GenErr

Overall Test Case Results: Passed

Object Test Case TC-O-210
VDOT Implemented: Yes
Std Par Ref 5.6.8.8
OID 1.3.6.1.4.1.1206.4.2.3.5.8.1.8.5.2
Object Name dmsMessageRunTimePriority
Syntax Access Status
INTEGER (1..255) read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 1 Success
2 - Set Object to Min. Value 1 Success
3 - Set Object to Max. Value 1 Success
4 - Attempt Write to Read-Only Object   Skipped - Not read only
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 256 Success - did not write greater than Max
7 - Attempt to Set Value < Min. 0 Success - did not write less than Min
8 - Restore Object to Original Value   Failed - GenErr

Overall Test Case Results: Passed

Object Test Case TC-O-211
VDOT Implemented: Yes
Std Par Ref 5.6.8.8
OID 1.3.6.1.4.1.1206.4.2.3.5.8.1.8.6.1
Object Name dmsMessageRunTimePriority
Syntax Access Status
INTEGER (1..255) read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 1 Success
2 - Set Object to Min. Value 1 Success
3 - Set Object to Max. Value 255 Success
4 - Attempt Write to Read-Only Object   Skipped - Not read only
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 256 Success - did not write greater than Max
7 - Attempt to Set Value < Min. 0 Success - did not write less than Min
8 - Restore Object to Original Value 1 Success

Overall Test Case Results: Passed

Object Test Case TC-O-212
VDOT Implemented: Yes
Std Par Ref 5.6.8.8
OID 1.3.6.1.4.1.1206.4.2.3.5.8.1.8.6.2
Object Name dmsMessageRunTimePriority
Syntax Access Status
INTEGER (1..255) read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 1 Success
2 - Set Object to Min. Value 1 Success
3 - Set Object to Max. Value 1 Success
4 - Attempt Write to Read-Only Object   Skipped - Not read only
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 256 Success - did not write greater than Max
7 - Attempt to Set Value < Min. 0 Success - did not write less than Min
8 - Restore Object to Original Value   Failed - GenErr

Overall Test Case Results: Passed

Object Test Case TC-O-213
VDOT Implemented: Yes
Std Par Ref 5.6.8.9
OID 1.3.6.1.4.1.1206.4.2.3.5.8.1.9.2.1
Object Name dmsMessageStatus
Syntax Access Status
INTEGER {enumeration} read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 4 (valid) Success
2 - Set Object to Min. Value 4 (valid) Success
3 - Set Object to Max. Value 5 (error) Success
4 - Attempt Write to Read-Only Object   Skipped - Not read only
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max.   Skipped - no Minimum
7 - Attempt to Set Value < Min.   Skipped - no Minimum
8 - Restore Object to Original Value   Failed - GenErr

Overall Test Case Results: Passed

Object Test Case TC-O-214
VDOT Implemented: Yes
Std Par Ref 5.6.8.9
OID 1.3.6.1.4.1.1206.4.2.3.5.8.1.9.2.2
Object Name dmsMessageStatus
Syntax Access Status
INTEGER {enumeration} read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 4 (valid) Success
2 - Set Object to Min. Value 4 (valid) Success
3 - Set Object to Max. Value 5 (error) Success
4 - Attempt Write to Read-Only Object   Skipped - Not read only
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max.   Skipped - no Minimum
7 - Attempt to Set Value < Min.   Skipped - no Minimum
8 - Restore Object to Original Value   Failed - GenErr

Overall Test Case Results: Passed

Object Test Case TC-O-215
VDOT Implemented: Yes
Std Par Ref 5.6.8.9
OID 1.3.6.1.4.1.1206.4.2.3.5.8.1.9.3.1
Object Name dmsMessageStatus
Syntax Access Status
INTEGER {enumeration} read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 4 (valid) Success
2 - Set Object to Min. Value 4 (valid) Success
3 - Set Object to Max. Value 4 (valid) Success
4 - Attempt Write to Read-Only Object   Skipped - Not read only
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max.   Skipped - no Minimum
7 - Attempt to Set Value < Min.   Skipped - no Minimum
8 - Restore Object to Original Value   Failed - GenErr

Overall Test Case Results: Passed

Object Test Case TC-O-216
VDOT Implemented: Yes
Std Par Ref 5.6.8.9
OID 1.3.6.1.4.1.1206.4.2.3.5.8.1.9.3.2
Object Name dmsMessageStatus
Syntax Access Status
INTEGER {enumeration} read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 4 (valid) Success
2 - Set Object to Min. Value 4 (valid) Success
3 - Set Object to Max. Value 4 (valid) Success
4 - Attempt Write to Read-Only Object   Skipped - Not read only
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max.   Skipped - no Minimum
7 - Attempt to Set Value < Min.   Skipped - no Minimum
8 - Restore Object to Original Value   Failed - GenErr

Overall Test Case Results: Passed

Object Test Case TC-O-217
VDOT Implemented: Yes
Std Par Ref 5.6.8.9
OID 1.3.6.1.4.1.1206.4.2.3.5.8.1.9.4.1
Object Name dmsMessageStatus
Syntax Access Status
INTEGER {enumeration} read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 4 (valid) Success
2 - Set Object to Min. Value 4 (valid) Success
3 - Set Object to Max. Value 4 (valid) Success
4 - Attempt Write to Read-Only Object   Skipped - Not read only
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max.   Skipped - no Minimum
7 - Attempt to Set Value < Min.   Skipped - no Minimum
8 - Restore Object to Original Value   Failed - GenErr

Overall Test Case Results: Passed

Object Test Case TC-O-218
VDOT Implemented: Yes
Std Par Ref 5.6.8.9
OID 1.3.6.1.4.1.1206.4.2.3.5.8.1.9.4.2
Object Name dmsMessageStatus
Syntax Access Status
INTEGER {enumeration} read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 1 (notUsed) Success
2 - Set Object to Min. Value 1 (notUsed) Success
3 - Set Object to Max. Value 1 (notUsed) Success
4 - Attempt Write to Read-Only Object   Skipped - Not read only
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max.   Skipped - no Minimum
7 - Attempt to Set Value < Min.   Skipped - no Minimum
8 - Restore Object to Original Value   Failed - GenErr

Overall Test Case Results: Passed

Object Test Case TC-O-219
VDOT Implemented: Yes
Std Par Ref 5.6.8.9
OID 1.3.6.1.4.1.1206.4.2.3.5.8.1.9.5.1
Object Name dmsMessageStatus
Syntax Access Status
INTEGER {enumeration} read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 1 (notUsed) Success
2 - Set Object to Min. Value 1 (notUsed) Success
3 - Set Object to Max. Value 1 (notUsed) Success
4 - Attempt Write to Read-Only Object   Skipped - Not read only
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max.   Skipped - no Minimum
7 - Attempt to Set Value < Min.   Skipped - no Minimum
8 - Restore Object to Original Value   Failed - GenErr

Overall Test Case Results: Passed

Object Test Case TC-O-220
VDOT Implemented: Yes
Std Par Ref 5.6.8.9
OID 1.3.6.1.4.1.1206.4.2.3.5.8.1.9.5.2
Object Name dmsMessageStatus
Syntax Access Status
INTEGER {enumeration} read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 1 (notUsed) Success
2 - Set Object to Min. Value 1 (notUsed) Success
3 - Set Object to Max. Value 1 (notUsed) Success
4 - Attempt Write to Read-Only Object   Skipped - Not read only
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max.   Skipped - no Minimum
7 - Attempt to Set Value < Min.   Skipped - no Minimum
8 - Restore Object to Original Value   Failed - GenErr

Overall Test Case Results: Passed

Object Test Case TC-O-221
VDOT Implemented: Yes
Std Par Ref 5.6.8.9
OID 1.3.6.1.4.1.1206.4.2.3.5.8.1.9.6.1
Object Name dmsMessageStatus
Syntax Access Status
INTEGER {enumeration} read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 4 (valid) Success
2 - Set Object to Min. Value 4 (valid) Success
3 - Set Object to Max. Value 4 (valid) Success
4 - Attempt Write to Read-Only Object   Skipped - Not read only
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max.   Skipped - no Minimum
7 - Attempt to Set Value < Min.   Skipped - no Minimum
8 - Restore Object to Original Value   Failed - GenErr

Overall Test Case Results: Passed

Object Test Case TC-O-222
VDOT Implemented: Yes
Std Par Ref 5.6.8.9
OID 1.3.6.1.4.1.1206.4.2.3.5.8.1.9.6.2
Object Name dmsMessageStatus
Syntax Access Status
INTEGER {enumeration} read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 1 (notUsed) Success
2 - Set Object to Min. Value 1 (notUsed) Success
3 - Set Object to Max. Value 1 (notUsed) Success
4 - Attempt Write to Read-Only Object   Skipped - Not read only
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max.   Skipped - no Minimum
7 - Attempt to Set Value < Min.   Skipped - no Minimum
8 - Restore Object to Original Value   Failed - GenErr

Overall Test Case Results: Passed

Object Test Case TC-O-223
VDOT Implemented: Yes
Std Par Ref 5.6.8.10
OID 1.3.6.1.4.1.1206.4.2.3.5.8.1.10.2.1
Object Name dmsMessageName
Syntax Access Status
DisplayString (SIZE (0..64)) read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object   Success
2 - Set Object to Min. Value   Success
3 - Set Object to Max. Value   Success
4 - Attempt Write to Read-Only Object 00 Skipped - Not read only
5 - Attempt Read of Non-Accessible Object 00 Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 1 Success - did not write greater than Max
7 - Attempt to Set Value < Min. -1 Success - did not write less than Min
8 - Restore Object to Original Value 00 Failed - GenErr

Overall Test Case Results: Passed

Object Test Case TC-O-224
VDOT Implemented: Yes
Std Par Ref 5.6.8.10
OID 1.3.6.1.4.1.1206.4.2.3.5.8.1.10.2.2
Object Name dmsMessageName
Syntax Access Status
DisplayString (SIZE (0..64)) read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object   Success
2 - Set Object to Min. Value   Success
3 - Set Object to Max. Value   Success
4 - Attempt Write to Read-Only Object 00 Skipped - Not read only
5 - Attempt Read of Non-Accessible Object 00 Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 1 Success - did not write greater than Max
7 - Attempt to Set Value < Min. -1 Success - did not write less than Min
8 - Restore Object to Original Value 00 Failed - GenErr

Overall Test Case Results: Passed

Object Test Case TC-O-225
VDOT Implemented: Yes
Std Par Ref 5.6.8.10
OID 1.3.6.1.4.1.1206.4.2.3.5.8.1.10.3.1
Object Name dmsMessageName
Syntax Access Status
DisplayString (SIZE (0..64)) read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object   Success
2 - Set Object to Min. Value   Success
3 - Set Object to Max. Value   Success
4 - Attempt Write to Read-Only Object 00 Skipped - Not read only
5 - Attempt Read of Non-Accessible Object 00 Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 1 Success - did not write greater than Max
7 - Attempt to Set Value < Min. -1 Success - did not write less than Min
8 - Restore Object to Original Value 00 Failed - GenErr

Overall Test Case Results: Passed

Object Test Case TC-O-226
VDOT Implemented: Yes
Std Par Ref 5.6.8.10
OID 1.3.6.1.4.1.1206.4.2.3.5.8.1.10.3.2
Object Name dmsMessageName
Syntax Access Status
DisplayString (SIZE (0..64)) read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object   Success
2 - Set Object to Min. Value   Success
3 - Set Object to Max. Value   Success
4 - Attempt Write to Read-Only Object 00 Skipped - Not read only
5 - Attempt Read of Non-Accessible Object 00 Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 1 Success - did not write greater than Max
7 - Attempt to Set Value < Min. -1 Success - did not write less than Min
8 - Restore Object to Original Value 00 Failed - GenErr

Overall Test Case Results: Passed

Object Test Case TC-O-227
VDOT Implemented: Yes
Std Par Ref 5.6.8.10
OID 1.3.6.1.4.1.1206.4.2.3.5.8.1.10.4.1
Object Name dmsMessageName
Syntax Access Status
DisplayString (SIZE (0..64)) read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object V1 Success
2 - Set Object to Min. Value V1 Success
3 - Set Object to Max. Value V1 Success
4 - Attempt Write to Read-Only Object 00 Skipped - Not read only
5 - Attempt Read of Non-Accessible Object 00 Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 1 Success - did not write greater than Max
7 - Attempt to Set Value < Min. -1 Success - did not write less than Min
8 - Restore Object to Original Value 00 Failed - GenErr

Overall Test Case Results: Passed

Object Test Case TC-O-228
VDOT Implemented: Yes
Std Par Ref 5.6.8.10
OID 1.3.6.1.4.1.1206.4.2.3.5.8.1.10.4.2
Object Name dmsMessageName
Syntax Access Status
DisplayString (SIZE (0..64)) read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object   Success
2 - Set Object to Min. Value   Success
3 - Set Object to Max. Value   Success
4 - Attempt Write to Read-Only Object 00 Skipped - Not read only
5 - Attempt Read of Non-Accessible Object 00 Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 1 Success - did not write greater than Max
7 - Attempt to Set Value < Min. -1 Success - did not write less than Min
8 - Restore Object to Original Value 00 Failed - GenErr

Overall Test Case Results: Passed

Object Test Case TC-O-229
VDOT Implemented: Yes
Std Par Ref 5.6.8.10
OID 1.3.6.1.4.1.1206.4.2.3.5.8.1.10.5.1
Object Name dmsMessageName
Syntax Access Status
DisplayString (SIZE (0..64)) read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object   Success
2 - Set Object to Min. Value   Success
3 - Set Object to Max. Value   Success
4 - Attempt Write to Read-Only Object 00 Skipped - Not read only
5 - Attempt Read of Non-Accessible Object 00 Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 1 Success - did not write greater than Max
7 - Attempt to Set Value < Min. -1 Success - did not write less than Min
8 - Restore Object to Original Value 00 Failed - GenErr

Overall Test Case Results: Passed

Object Test Case TC-O-230
VDOT Implemented: Yes
Std Par Ref 5.6.8.10
OID 1.3.6.1.4.1.1206.4.2.3.5.8.1.10.5.2
Object Name dmsMessageName
Syntax Access Status
DisplayString (SIZE (0..64)) read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object   Success
2 - Set Object to Min. Value   Success
3 - Set Object to Max. Value   Success
4 - Attempt Write to Read-Only Object 00 Skipped - Not read only
5 - Attempt Read of Non-Accessible Object 00 Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 1 Success - did not write greater than Max
7 - Attempt to Set Value < Min. -1 Success - did not write less than Min
8 - Restore Object to Original Value 00 Failed - GenErr

Overall Test Case Results: Passed

Object Test Case TC-O-231
VDOT Implemented: Yes
Std Par Ref 5.6.8.10
OID 1.3.6.1.4.1.1206.4.2.3.5.8.1.10.6.1
Object Name dmsMessageName
Syntax Access Status
DisplayString (SIZE (0..64)) read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object   Success
2 - Set Object to Min. Value   Success
3 - Set Object to Max. Value   Success
4 - Attempt Write to Read-Only Object 00 Skipped - Not read only
5 - Attempt Read of Non-Accessible Object 00 Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 1 Success - did not write greater than Max
7 - Attempt to Set Value < Min. -1 Success - did not write less than Min
8 - Restore Object to Original Value 00 Failed - GenErr

Overall Test Case Results: Passed

Object Test Case TC-O-232
VDOT Implemented: Yes
Std Par Ref 5.6.8.10
OID 1.3.6.1.4.1.1206.4.2.3.5.8.1.10.6.2
Object Name dmsMessageName
Syntax Access Status
DisplayString (SIZE (0..64)) read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object   Success
2 - Set Object to Min. Value   Success
3 - Set Object to Max. Value   Success
4 - Attempt Write to Read-Only Object 00 Skipped - Not read only
5 - Attempt Read of Non-Accessible Object 00 Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 1 Success - did not write greater than Max
7 - Attempt to Set Value < Min. -1 Success - did not write less than Min
8 - Restore Object to Original Value 00 Failed - GenErr

Overall Test Case Results: Passed

Object Test Case TC-O-233
VDOT Implemented: Yes
Std Par Ref 5.6.9
OID 1.3.6.1.4.1.1206.4.2.3.5.9.0
Object Name dmsValidateMessageError
Syntax Access Status
INTEGER {enumeration} read-only optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 2 (none) Success
2 - Set Object to Min. Value 2 (none) Success
3 - Set Object to Max. Value 2 (none) Success
4 - Attempt Write to Read-Only Object   Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max.   Skipped - not writable
7 - Attempt to Set Value < Min.   Skipped - not writable
8 - Restore Object to Original Value   Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-234
VDOT Implemented: Yes
Std Par Ref 5.7.1
OID 1.3.6.1.4.1.1206.4.2.3.6.1.0
Object Name dmsControlMode
Syntax Access Status
INTEGER {enumeration} read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 4 (central) Success
2 - Set Object to Min. Value 4 (central) Success
3 - Set Object to Max. Value 4 (central) Success
4 - Attempt Write to Read-Only Object   Skipped - Not read only
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max.   Skipped - no Minimum
7 - Attempt to Set Value < Min.   Skipped - no Minimum
8 - Restore Object to Original Value   Failed - BadValue

Overall Test Case Results: Passed

Object Test Case TC-O-235
VDOT Implemented: Yes
Std Par Ref 5.7.2
OID 1.3.6.1.4.1.1206.4.2.3.6.2.0
Object Name dmsSWReset
Syntax Access Status
INTEGER (0..1) read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 0 Success
2 - Set Object to Min. Value 0 Success
3 - Set Object to Max. Value 0 Success
4 - Attempt Write to Read-Only Object   Skipped - Not read only
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 2 Success - did not write greater than Max
7 - Attempt to Set Value < Min. -1 Success - did not write less than Min
8 - Restore Object to Original Value 0 Success

Overall Test Case Results: Passed

Object Test Case TC-O-236
VDOT Implemented: Yes
Std Par Ref 5.7.3
OID 1.3.6.1.4.1.1206.4.2.3.6.3.0
Object Name dmsActivateMessage
Syntax Access Status
MessageActivationCode read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 00 00 00 00 00 00 00 00 00 00 00 00 Success
2 - Set Object to Min. Value 00 00 00 00 00 00 00 00 00 00 00 00 Success
3 - Set Object to Max. Value 00 00 00 00 00 00 00 00 00 00 00 00 Success
4 - Attempt Write to Read-Only Object 00 Skipped - Not read only
5 - Attempt Read of Non-Accessible Object 00 Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 00 Skipped - no Minimum
7 - Attempt to Set Value < Min. 00 Skipped - no Minimum
8 - Restore Object to Original Value 00 Failed - GenErr

Overall Test Case Results: Passed

Object Test Case TC-O-237
VDOT Implemented: Yes
Std Par Ref 5.7.4
OID 1.3.6.1.4.1.1206.4.2.3.6.4.0
Object Name dmsMessageTimeRemaining
Syntax Access Status
INTEGER (0..65535) read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 0 Success
2 - Set Object to Min. Value 0 Success
3 - Set Object to Max. Value 0 Success
4 - Attempt Write to Read-Only Object   Skipped - Not read only
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 65536 Success - did not write greater than Max
7 - Attempt to Set Value < Min. -1 Failed - wrote less than Min
8 - Restore Object to Original Value 0 Success

Overall Test Case Results: Passed

Object Test Case TC-O-238
VDOT Implemented: Yes
Std Par Ref 5.7.5
OID 1.3.6.1.4.1.1206.4.2.3.6.5.0
Object Name dmsMsgTableSource
Syntax Access Status
MessageIDCode read-only optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 00 00 00 00 00 Success
2 - Set Object to Min. Value 00 00 00 00 00 Success
3 - Set Object to Max. Value 00 00 00 00 00 Success
4 - Attempt Write to Read-Only Object 00 Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object 00 Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 00 Skipped - not writable
7 - Attempt to Set Value < Min. 00 Skipped - not writable
8 - Restore Object to Original Value 00 Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-239
VDOT Implemented: Yes
Std Par Ref 5.7.6
OID 1.3.6.1.4.1.1206.4.2.3.6.6.0
Object Name dmsMsgRequesterID
Syntax Access Status
IpAddress read-only optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 00 00 00 00 Success
2 - Set Object to Min. Value 00 00 00 00 Success
3 - Set Object to Max. Value 00 00 00 00 Success
4 - Attempt Write to Read-Only Object 00 Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object 00 Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 00 Skipped - not writable
7 - Attempt to Set Value < Min. 00 Skipped - not writable
8 - Restore Object to Original Value 00 Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-240
VDOT Implemented: Yes
Std Par Ref 5.7.7
OID 1.3.6.1.4.1.1206.4.2.3.6.7.0
Object Name dmsMsgSourceMode
Syntax Access Status
INTEGER {enumeration} read-only optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 1 (other) Success
2 - Set Object to Min. Value 10 (powerRecovery) Success
3 - Set Object to Max. Value 11 (reset) Success
4 - Attempt Write to Read-Only Object   Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max.   Skipped - not writable
7 - Attempt to Set Value < Min.   Skipped - not writable
8 - Restore Object to Original Value   Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-241
VDOT Implemented: Yes
Std Par Ref 5.7.8
OID 1.3.6.1.4.1.1206.4.2.3.6.8.0
Object Name dmsShortPowerRecoveryMessage
Syntax Access Status
MessageIDCode read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 07 00 FF 00 00 Success
2 - Set Object to Min. Value 07 00 FF 00 00 Success
3 - Set Object to Max. Value 07 00 FF 00 00 Success
4 - Attempt Write to Read-Only Object 00 Skipped - Not read only
5 - Attempt Read of Non-Accessible Object 00 Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 00 Skipped - no Minimum
7 - Attempt to Set Value < Min. 00 Skipped - no Minimum
8 - Restore Object to Original Value 07 00 FF 00 00 Success

Overall Test Case Results: Passed

Object Test Case TC-O-242
VDOT Implemented: Yes
Std Par Ref 5.7.9
OID 1.3.6.1.4.1.1206.4.2.3.6.9.0
Object Name dmsLongPowerRecoveryMessage
Syntax Access Status
MessageIDCode read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 07 00 FF 00 00 Success
2 - Set Object to Min. Value 07 00 FF 00 00 Success
3 - Set Object to Max. Value 07 00 FF 00 00 Success
4 - Attempt Write to Read-Only Object 00 Skipped - Not read only
5 - Attempt Read of Non-Accessible Object 00 Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 00 Skipped - no Minimum
7 - Attempt to Set Value < Min. 00 Skipped - no Minimum
8 - Restore Object to Original Value 07 00 FF 00 00 Success

Overall Test Case Results: Passed

Object Test Case TC-O-243
VDOT Implemented: Yes
Std Par Ref 5.7.10
OID 1.3.6.1.4.1.1206.4.2.3.6.10.0
Object Name dmsShortPowerLossTime
Syntax Access Status
INTEGER (0..65535) read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 0 Success
2 - Set Object to Min. Value 0 Success
3 - Set Object to Max. Value 65535 Success
4 - Attempt Write to Read-Only Object   Skipped - Not read only
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 65536 Success - did not write greater than Max
7 - Attempt to Set Value < Min. -1 Failed - wrote less than Min
8 - Restore Object to Original Value 0 Success

Overall Test Case Results: Passed

Object Test Case TC-O-244
VDOT Implemented: Yes
Std Par Ref 5.7.11
OID 1.3.6.1.4.1.1206.4.2.3.6.11.0
Object Name dmsResetMessage
Syntax Access Status
MessageIDCode read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 07 00 FF 00 00 Success
2 - Set Object to Min. Value 07 00 FF 00 00 Success
3 - Set Object to Max. Value 07 00 FF 00 00 Success
4 - Attempt Write to Read-Only Object 00 Skipped - Not read only
5 - Attempt Read of Non-Accessible Object 00 Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 00 Skipped - no Minimum
7 - Attempt to Set Value < Min. 00 Skipped - no Minimum
8 - Restore Object to Original Value 07 00 FF 00 00 Success

Overall Test Case Results: Passed

Object Test Case TC-O-245
VDOT Implemented: Yes
Std Par Ref 5.7.12
OID 1.3.6.1.4.1.1206.4.2.3.6.12.0
Object Name dmsCommunicationsLossMessage
Syntax Access Status
MessageIDCode read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 07 00 FF 00 00 Success
2 - Set Object to Min. Value 07 00 FF 00 00 Success
3 - Set Object to Max. Value 07 00 FF 00 00 Success
4 - Attempt Write to Read-Only Object 00 Skipped - Not read only
5 - Attempt Read of Non-Accessible Object 00 Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 00 Skipped - no Minimum
7 - Attempt to Set Value < Min. 00 Skipped - no Minimum
8 - Restore Object to Original Value 07 00 FF 00 00 Success

Overall Test Case Results: Passed

Object Test Case TC-O-246
VDOT Implemented: Yes
Std Par Ref 5.7.13
OID 1.3.6.1.4.1.1206.4.2.3.6.13.0
Object Name dmsTimeCommLoss
Syntax Access Status
INTEGER (0..65535) read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 255 Success
2 - Set Object to Min. Value 0 Success
3 - Set Object to Max. Value 65535 Success
4 - Attempt Write to Read-Only Object   Skipped - Not read only
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 65536 Success - did not write greater than Max
7 - Attempt to Set Value < Min. -1 Failed - wrote less than Min
8 - Restore Object to Original Value   Failed - TimeOut

Overall Test Case Results: Passed

Object Test Case TC-O-247
VDOT Implemented: Yes
Std Par Ref 5.7.14
OID 1.3.6.1.4.1.1206.4.2.3.6.14.0
Object Name dmsPowerLossMessage
Syntax Access Status
MessageIDCode read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 00 Failed - NoSuchName
2 - Set Object to Min. Value 00 Failed - NoSuchName
3 - Set Object to Max. Value 00 Failed - NoSuchName
4 - Attempt Write to Read-Only Object 00 Skipped - Not read only
5 - Attempt Read of Non-Accessible Object 00 Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 00 Skipped - no Minimum
7 - Attempt to Set Value < Min. 00 Skipped - no Minimum
8 - Restore Object to Original Value 00 Failed - TimeOut

Overall Test Case Results: Passed

Object Test Case TC-O-248
VDOT Implemented: Yes
Std Par Ref 5.7.15
OID 1.3.6.1.4.1.1206.4.2.3.6.15.0
Object Name dmsEndDurationMessage
Syntax Access Status
MessageIDCode read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 07 00 FF 00 00 Success
2 - Set Object to Min. Value 07 00 FF 00 00 Success
3 - Set Object to Max. Value 07 00 FF 00 00 Success
4 - Attempt Write to Read-Only Object 00 Skipped - Not read only
5 - Attempt Read of Non-Accessible Object 00 Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 00 Skipped - no Minimum
7 - Attempt to Set Value < Min. 00 Skipped - no Minimum
8 - Restore Object to Original Value 00 Failed - TimeOut

Overall Test Case Results: Passed

Object Test Case TC-O-249
VDOT Implemented: Yes
Std Par Ref 5.7.16
OID 1.3.6.1.4.1.1206.4.2.3.6.16.0
Object Name dmsMemoryMgmt
Syntax Access Status
INTEGER {enumeration} read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 2 (normal) Success
2 - Set Object to Min. Value 2 (normal) Success
3 - Set Object to Max. Value 2 (normal) Success
4 - Attempt Write to Read-Only Object   Skipped - Not read only
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max.   Skipped - no Minimum
7 - Attempt to Set Value < Min.   Skipped - no Minimum
8 - Restore Object to Original Value   Failed - TimeOut

Overall Test Case Results: Passed

Object Test Case TC-O-250
VDOT Implemented: Yes
Std Par Ref 5.7.17
OID 1.3.6.1.4.1.1206.4.2.3.6.17.0
Object Name dmsActivateMsgError
Syntax Access Status
INTEGER {enumeration} read-only optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 2 (none) Success
2 - Set Object to Min. Value 2 (none) Success
3 - Set Object to Max. Value 2 (none) Success
4 - Attempt Write to Read-Only Object   Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max.   Skipped - not writable
7 - Attempt to Set Value < Min.   Skipped - not writable
8 - Restore Object to Original Value   Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-251
VDOT Implemented: Yes
Std Par Ref 5.7.18
OID 1.3.6.1.4.1.1206.4.2.3.6.18.0
Object Name dmsMultiSyntaxError
Syntax Access Status
INTEGER {enumeration} read-only optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 2 (none) Success
2 - Set Object to Min. Value 2 (none) Success
3 - Set Object to Max. Value 2 (none) Success
4 - Attempt Write to Read-Only Object   Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max.   Skipped - not writable
7 - Attempt to Set Value < Min.   Skipped - not writable
8 - Restore Object to Original Value   Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-252
VDOT Implemented: Yes
Std Par Ref 5.7.19
OID 1.3.6.1.4.1.1206.4.2.3.6.19.0
Object Name dmsMultiSyntaxErrorPosition
Syntax Access Status
INTEGER (0..65535) read-only optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 0 Success
2 - Set Object to Min. Value 0 Success
3 - Set Object to Max. Value 6 Success
4 - Attempt Write to Read-Only Object   Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max.   Skipped - not writable
7 - Attempt to Set Value < Min.   Skipped - not writable
8 - Restore Object to Original Value   Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-253
VDOT Implemented: Yes
Std Par Ref 5.7.20
OID 1.3.6.1.4.1.1206.4.2.3.6.20.0
Object Name dmsMultiOtherErrorDescription
Syntax Access Status
DisplayString (SIZE (0..50)) read-only optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object   Success
2 - Set Object to Min. Value   Success
3 - Set Object to Max. Value   Success
4 - Attempt Write to Read-Only Object 00 Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object 00 Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 00 Skipped - not writable
7 - Attempt to Set Value < Min. 00 Skipped - not writable
8 - Restore Object to Original Value 00 Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-254
VDOT Implemented: Yes
Std Par Ref 5.7.21
OID 1.3.6.1.4.1.1206.4.2.3.6.21.0
Object Name vmsPixelServiceDuration
Syntax Access Status
INTEGER (0..65535) read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 255 Success
2 - Set Object to Min. Value 255 Success
3 - Set Object to Max. Value 255 Success
4 - Attempt Write to Read-Only Object   Skipped - Not read only
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 65536 Success - did not write greater than Max
7 - Attempt to Set Value < Min. -1 Failed - wrote less than Min
8 - Restore Object to Original Value   Failed - TimeOut

Overall Test Case Results: Passed

Object Test Case TC-O-255
VDOT Implemented: Yes
Std Par Ref 5.7.22
OID 1.3.6.1.4.1.1206.4.2.3.6.22.0
Object Name vmsPixelServiceFrequency
Syntax Access Status
INTEGER (0..1440) read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 255 Success
2 - Set Object to Min. Value 255 Success
3 - Set Object to Max. Value 255 Success
4 - Attempt Write to Read-Only Object   Skipped - Not read only
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 1441 Success - did not write greater than Max
7 - Attempt to Set Value < Min. -1 Failed - wrote less than Min
8 - Restore Object to Original Value   Failed - TimeOut

Overall Test Case Results: Passed

Object Test Case TC-O-256
VDOT Implemented: Yes
Std Par Ref 5.7.23
OID 1.3.6.1.4.1.1206.4.2.3.6.23.0
Object Name vmsPixelServiceTime
Syntax Access Status
INTEGER (0..1440) read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 0 Success
2 - Set Object to Min. Value 0 Success
3 - Set Object to Max. Value 0 Success
4 - Attempt Write to Read-Only Object   Skipped - Not read only
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 1441 Success - did not write greater than Max
7 - Attempt to Set Value < Min. -1 Failed - wrote less than Min
8 - Restore Object to Original Value 0 Success

Overall Test Case Results: Passed

Object Test Case TC-O-257
VDOT Implemented: Yes
Std Par Ref 5.7.24
OID 1.3.6.1.4.1.1206.4.2.3.6.26.0
Object Name dmsActivateErrorMsgCode
Syntax Access Status
MessageActivationCode read-only optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 00 00 00 00 00 00 00 00 00 00 00 00 Success
2 - Set Object to Min. Value 00 00 00 00 00 00 00 00 00 00 00 00 Success
3 - Set Object to Max. Value 00 00 00 00 00 00 00 00 00 00 00 00 Success
4 - Attempt Write to Read-Only Object 00 Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object 00 Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 00 Skipped - not writable
7 - Attempt to Set Value < Min. 00 Skipped - not writable
8 - Restore Object to Original Value 00 Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-258
VDOT Implemented: Yes
Std Par Ref 5.7.25.1
OID 1.3.6.1.4.1.1206.4.2.3.6.25.1.0
Object Name eventControlMaxTriggers
Syntax Access Status
INTEGER (0..255) read-only optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object   Failed - NoSuchName
2 - Set Object to Min. Value   Failed - NoSuchName
3 - Set Object to Max. Value   Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max.   Skipped - not writable
7 - Attempt to Set Value < Min.   Skipped - not writable
8 - Restore Object to Original Value   Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-259
VDOT Implemented: Yes
Std Par Ref 5.7.25.2
OID 1.3.6.1.4.1.1206.4.2.3.6.25.2.0
Object Name eventControlNumTriggers
Syntax Access Status
INTEGER (0..255) read-only optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object   Failed - NoSuchName
2 - Set Object to Min. Value   Failed - NoSuchName
3 - Set Object to Max. Value   Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max.   Skipped - not writable
7 - Attempt to Set Value < Min.   Skipped - not writable
8 - Restore Object to Original Value   Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-260
VDOT Implemented: Yes
Std Par Ref 5.7.25.3.1
OID 1.3.6.1.4.1.1206.4.2.3.6.25.3.1.1.1
Object Name eventControlConfigNumber
Syntax Access Status
INTEGER (1..255) read-only optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object   Failed - NoSuchName
2 - Set Object to Min. Value   Failed - NoSuchName
3 - Set Object to Max. Value   Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max.   Skipped - not writable
7 - Attempt to Set Value < Min.   Skipped - not writable
8 - Restore Object to Original Value   Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-261
VDOT Implemented: Yes
Std Par Ref 5.7.25.3.2
OID 1.3.6.1.4.1.1206.4.2.3.6.25.3.1.2.1
Object Name eventControlMonitoredObject
Syntax Access Status
OBJECT IDENTIFIER read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object   Failed - NoSuchName
2 - Set Object to Min. Value   Failed - NoSuchName
3 - Set Object to Max. Value   Failed - NoSuchName
4 - Attempt Write to Read-Only Object   Skipped - Not read only
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max.   Skipped - no Minimum
7 - Attempt to Set Value < Min.   Skipped - no Minimum
8 - Restore Object to Original Value   Failed - NoSuchName

Overall Test Case Results: Passed

Object Test Case TC-O-262
VDOT Implemented: Yes
Std Par Ref 5.7.25.3.3
OID 1.3.6.1.4.1.1206.4.2.3.6.25.3.1.3.1
Object Name eventControlConfigOperator
Syntax Access Status
INTEGER {enumeration} read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object   Failed - NoSuchName
2 - Set Object to Min. Value   Failed - NoSuchName
3 - Set Object to Max. Value   Failed - NoSuchName
4 - Attempt Write to Read-Only Object   Skipped - Not read only
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max.   Skipped - no Minimum
7 - Attempt to Set Value < Min.   Skipped - no Minimum

Overall Test Case Results: Passed

Object Test Case TC-O-263
VDOT Implemented: Yes
Std Par Ref 5.7.25.3.4
OID 1.3.6.1.4.1.1206.4.2.3.6.25.3.1.4.1
Object Name eventControlCompareValue1
Syntax Access Status
INTEGER (0.. 4294967295) read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object   Failed - NoSuchName
2 - Set Object to Min. Value   Failed - NoSuchName
3 - Set Object to Max. Value   Failed - NoSuchName
4 - Attempt Write to Read-Only Object   Skipped - Not read only
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 4294967296 Success - did not write greater than Max
7 - Attempt to Set Value < Min. -1 Success - did not write less than Min

Overall Test Case Results: Passed

Object Test Case TC-O-264
VDOT Implemented: Yes
Std Par Ref 5.7.25.3.5
OID 1.3.6.1.4.1.1206.4.2.3.6.25.3.1.5.1
Object Name eventControlCompareValue2
Syntax Access Status
INTEGER (0.. 4294967295) read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object   Failed - NoSuchName
2 - Set Object to Min. Value   Failed - NoSuchName
3 - Set Object to Max. Value   Failed - NoSuchName
4 - Attempt Write to Read-Only Object   Skipped - Not read only
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 4294967296 Success - did not write greater than Max
7 - Attempt to Set Value < Min. -1 Success - did not write less than Min

Overall Test Case Results: Passed

Object Test Case TC-O-265
VDOT Implemented: Yes
Std Par Ref 5.7.25.3.6
OID 1.3.6.1.4.1.1206.4.2.3.6.25.3.1.6.1
Object Name eventControlCompareObject
Syntax Access Status
OBJECT IDENTIFIER read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object   Failed - NoSuchName
2 - Set Object to Min. Value   Failed - NoSuchName
3 - Set Object to Max. Value   Failed - NoSuchName
4 - Attempt Write to Read-Only Object   Skipped - Not read only
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max.   Skipped - no Minimum
7 - Attempt to Set Value < Min.   Skipped - no Minimum
8 - Restore Object to Original Value   Failed - NoSuchName

Overall Test Case Results: Passed

Object Test Case TC-O-266
VDOT Implemented: Yes
Std Par Ref 5.7.25.3.7
OID 1.3.6.1.4.1.1206.4.2.3.6.25.3.1.7.1
Object Name eventControlDelay
Syntax Access Status
INTEGER (-2147483647..2147483647) read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object   Failed - NoSuchName
2 - Set Object to Min. Value   Failed - NoSuchName
3 - Set Object to Max. Value   Failed - NoSuchName
4 - Attempt Write to Read-Only Object   Skipped - Not read only
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 2147483648 Success - did not write greater than Max
7 - Attempt to Set Value < Min. -2147483648 Success - did not write less than Min

Overall Test Case Results: Passed

Object Test Case TC-O-267
VDOT Implemented: Yes
Std Par Ref 5.7.25.3.8
OID 1.3.6.1.4.1.1206.4.2.3.6.25.3.1.8.1
Object Name eventControlMessageCode
Syntax Access Status
OCTET STRING read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 00 Failed - NoSuchName
2 - Set Object to Min. Value 00 Failed - NoSuchName
3 - Set Object to Max. Value 00 Failed - NoSuchName
4 - Attempt Write to Read-Only Object 00 Skipped - Not read only
5 - Attempt Read of Non-Accessible Object 00 Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 00 Skipped - no Minimum
7 - Attempt to Set Value < Min. 00 Skipped - no Minimum
8 - Restore Object to Original Value 00 Failed - NoSuchName

Overall Test Case Results: Passed

Object Test Case TC-O-268
VDOT Implemented: Yes
Std Par Ref 5.7.25.3.9
OID 1.3.6.1.4.1.1206.4.2.3.6.25.3.1.9.1
Object Name eventControlTriggerMode
Syntax Access Status
INTEGER {enumeration} read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object   Failed - NoSuchName
2 - Set Object to Min. Value   Failed - NoSuchName
3 - Set Object to Max. Value   Failed - NoSuchName
4 - Attempt Write to Read-Only Object   Skipped - Not read only
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max.   Skipped - no Minimum
7 - Attempt to Set Value < Min.   Skipped - no Minimum

Overall Test Case Results: Passed

Object Test Case TC-O-269
VDOT Implemented: Yes
Std Par Ref 5.7.26
OID 1.3.6.1.4.1.1206.4.2.3.6.27.0
Object Name dmsActivateMessageState
Syntax Access Status
INTEGER {enumeration} read-only optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object   Failed - NoSuchName
2 - Set Object to Min. Value   Failed - NoSuchName
3 - Set Object to Max. Value   Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max.   Skipped - not writable
7 - Attempt to Set Value < Min.   Skipped - not writable
8 - Restore Object to Original Value   Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-270
VDOT Implemented: Yes
Std Par Ref 5.8.1
OID 1.3.6.1.4.1.1206.4.2.3.7.1.0
Object Name dmsIllumControl
Syntax Access Status
INTEGER {enumeration} read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 2 (photocell) Success
2 - Set Object to Min. Value 2 (photocell) Success
3 - Set Object to Max. Value 2 (photocell) Success
4 - Attempt Write to Read-Only Object   Skipped - Not read only
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max.   Skipped - no Minimum
7 - Attempt to Set Value < Min.   Skipped - no Minimum
8 - Restore Object to Original Value 2 (photocell) Success

Overall Test Case Results: Passed

Object Test Case TC-O-271
VDOT Implemented: Yes
Std Par Ref 5.8.2
OID 1.3.6.1.4.1.1206.4.2.3.7.2.0
Object Name dmsIllumMaxPhotocellLevel
Syntax Access Status
INTEGER (0..65535) read-only optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 65535 Success
2 - Set Object to Min. Value 65535 Success
3 - Set Object to Max. Value 65535 Success
4 - Attempt Write to Read-Only Object   Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max.   Skipped - not writable
7 - Attempt to Set Value < Min.   Skipped - not writable
8 - Restore Object to Original Value   Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-272
VDOT Implemented: Yes
Std Par Ref 5.8.3
OID 1.3.6.1.4.1.1206.4.2.3.7.3.0
Object Name dmsIllumPhotocellLevelStatus
Syntax Access Status
INTEGER (0..65535) read-only optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 0 Success
2 - Set Object to Min. Value 0 Success
3 - Set Object to Max. Value 0 Success
4 - Attempt Write to Read-Only Object   Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max.   Skipped - not writable
7 - Attempt to Set Value < Min.   Skipped - not writable
8 - Restore Object to Original Value   Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-273
VDOT Implemented: Yes
Std Par Ref 5.8.4
OID 1.3.6.1.4.1.1206.4.2.3.7.4.0
Object Name dmsIllumNumBrightLevels
Syntax Access Status
INTEGER (0..255) read-only optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 16 Success
2 - Set Object to Min. Value 16 Success
3 - Set Object to Max. Value 16 Success
4 - Attempt Write to Read-Only Object   Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max.   Skipped - not writable
7 - Attempt to Set Value < Min.   Skipped - not writable
8 - Restore Object to Original Value   Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-274
VDOT Implemented: Yes
Std Par Ref 5.8.5
OID 1.3.6.1.4.1.1206.4.2.3.7.5.0
Object Name dmsIllumBrightLevelStatus
Syntax Access Status
INTEGER (0..255) read-only optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 1 Success
2 - Set Object to Min. Value 1 Success
3 - Set Object to Max. Value 1 Success
4 - Attempt Write to Read-Only Object   Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max.   Skipped - not writable
7 - Attempt to Set Value < Min.   Skipped - not writable
8 - Restore Object to Original Value   Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-275
VDOT Implemented: Yes
Std Par Ref 5.8.6
OID 1.3.6.1.4.1.1206.4.2.3.7.6.0
Object Name dmsIllumManLevel
Syntax Access Status
INTEGER (0..255) read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 0 Success
2 - Set Object to Min. Value 0 Success
3 - Set Object to Max. Value 0 Success
4 - Attempt Write to Read-Only Object   Skipped - Not read only
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 256 Success - did not write greater than Max
7 - Attempt to Set Value < Min. -1 Success - did not write less than Min
8 - Restore Object to Original Value 0 Success

Overall Test Case Results: Passed

Object Test Case TC-O-276
VDOT Implemented: Yes
Std Par Ref 5.8.7
OID 1.3.6.1.4.1.1206.4.2.3.7.7.0
Object Name dmsIllumBrightnessValues
Syntax Access Status
OCTET STRING read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 10 05 14 00 00 01 F4 0A 29 01 F5 03 E8 0F 3D 03 E9 05 DC 14 52 05 DD 07 D0 19 66 07 D1 09 C4 1E 7B 09 C5 0B B8 23 8F 0B B9 0D AC 28 A4 0D AD 0F A0 2D 8B 0F A1 11 94 32 CD 11 95 13 88 3F 80 13 89 27 10 4C 33 27 11 3A 98 65 9A 3A 99 4E 20 7F 00 4E 21 75 ... Success
2 - Set Object to Min. Value 10 05 14 00 00 01 F4 0A 29 01 F5 03 E8 0F 3D 03 E9 05 DC 14 52 05 DD 07 D0 19 66 07 D1 09 C4 1E 7B 09 C5 0B B8 23 8F 0B B9 0D AC 28 A4 0D AD 0F A0 2D 8B 0F A1 11 94 32 CD 11 95 13 88 3F 80 13 89 27 10 4C 33 27 11 3A 98 65 9A 3A 99 4E 20 7F 00 4E 21 75 ... Success
3 - Set Object to Max. Value 10 05 14 00 00 01 F4 0A 29 01 F5 03 E8 0F 3D 03 E9 05 DC 14 52 05 DD 07 D0 19 66 07 D1 09 C4 1E 7B 09 C5 0B B8 23 8F 0B B9 0D AC 28 A4 0D AD 0F A0 2D 8B 0F A1 11 94 32 CD 11 95 13 88 3F 80 13 89 27 10 4C 33 27 11 3A 98 65 9A 3A 99 4E 20 7F 00 4E 21 75 ... Success
4 - Attempt Write to Read-Only Object 00 Skipped - Not read only
5 - Attempt Read of Non-Accessible Object 00 Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 00 Skipped - no Minimum
7 - Attempt to Set Value < Min. 00 Skipped - no Minimum
8 - Restore Object to Original Value 10 05 14 00 00 01 F4 0A 29 01 F5 03 E8 0F 3D 03 E9 05 DC 14 52 05 DD 07 D0 19 66 07 D1 09 C4 1E 7B 09 C5 0B B8 23 8F 0B B9 0D AC 28 A4 0D AD 0F A0 2D 8B 0F A1 11 94 32 CD 11 95 13 88 3F 80 13 89 27 10 4C 33 27 11 3A 98 65 9A 3A 99 4E 20 7F 00 4E 21 75 ... Success

Overall Test Case Results: Passed

Object Test Case TC-O-277
VDOT Implemented: Yes
Std Par Ref 5.8.8
OID 1.3.6.1.4.1.1206.4.2.3.7.8.0
Object Name dmsIllumBrightnessValuesError
Syntax Access Status
INTEGER {enumeration} read-only optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 2 (none) Success
2 - Set Object to Min. Value 2 (none) Success
3 - Set Object to Max. Value 2 (none) Success
4 - Attempt Write to Read-Only Object   Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max.   Skipped - not writable
7 - Attempt to Set Value < Min.   Skipped - not writable
8 - Restore Object to Original Value   Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-278
VDOT Implemented: Yes
Std Par Ref 5.8.9
OID 1.3.6.1.4.1.1206.4.2.3.7.9.0
Object Name dmsIllumLightOutputStatus
Syntax Access Status
INTEGER (0..65535) read-only optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 0 Success
2 - Set Object to Min. Value 0 Success
3 - Set Object to Max. Value 0 Success
4 - Attempt Write to Read-Only Object 0 Failed - wrote to read only
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max.   Skipped - not writable
7 - Attempt to Set Value < Min.   Skipped - not writable
8 - Restore Object to Original Value   Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-279
VDOT Implemented: Yes
Std Par Ref 5.9.1
OID 1.3.6.1.4.1.1206.4.2.3.8.1.0
Object Name numActionTableEntries
Syntax Access Status
INTEGER (0..255) read-only optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 64 Success
2 - Set Object to Min. Value 64 Success
3 - Set Object to Max. Value 64 Success
4 - Attempt Write to Read-Only Object   Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max.   Skipped - not writable
7 - Attempt to Set Value < Min.   Skipped - not writable
8 - Restore Object to Original Value   Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-280
VDOT Implemented: Yes
Std Par Ref 5.9.2.1
OID 1.3.6.1.4.1.1206.4.2.3.8.2.1.1.1
Object Name dmsActionIndex
Syntax Access Status
INTEGER (1..255) read-only optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 1 Success
2 - Set Object to Min. Value 1 Success
3 - Set Object to Max. Value 1 Success
4 - Attempt Write to Read-Only Object   Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max.   Skipped - not writable
7 - Attempt to Set Value < Min.   Skipped - not writable
8 - Restore Object to Original Value   Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-281
VDOT Implemented: Yes
Std Par Ref 5.9.2.2
OID 1.3.6.1.4.1.1206.4.2.3.8.2.1.2.1
Object Name dmsActionMsgCode
Syntax Access Status
MessageIDCode read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 04 00 01 4B 6B Success
2 - Set Object to Min. Value 04 00 01 4B 6B Success
3 - Set Object to Max. Value 04 00 01 4B 6B Success
4 - Attempt Write to Read-Only Object 00 Skipped - Not read only
5 - Attempt Read of Non-Accessible Object 00 Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 00 Skipped - no Minimum
7 - Attempt to Set Value < Min. 00 Skipped - no Minimum
8 - Restore Object to Original Value 04 00 01 4B 6B Success

Overall Test Case Results: Passed

Object Test Case TC-O-282
VDOT Implemented: Yes
Std Par Ref 5.11.1.1
OID 1.3.6.1.4.1.1206.4.2.3.9.1.0
Object Name statMultiFieldRows
Syntax Access Status
INTEGER (0..255) read-only optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 0 Success
2 - Set Object to Min. Value 0 Success
3 - Set Object to Max. Value 0 Success
4 - Attempt Write to Read-Only Object   Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max.   Skipped - not writable
7 - Attempt to Set Value < Min.   Skipped - not writable
8 - Restore Object to Original Value   Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-283
VDOT Implemented: Yes
Std Par Ref 5.11.1.3
OID 1.3.6.1.4.1.1206.4.2.3.9.3.0
Object Name dmsCurrentSpeed
Syntax Access Status
INTEGER (0..255) read-only optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object   Failed - NoSuchName
2 - Set Object to Min. Value   Failed - NoSuchName
3 - Set Object to Max. Value   Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max.   Skipped - not writable
7 - Attempt to Set Value < Min.   Skipped - not writable
8 - Restore Object to Original Value   Skipped - not writable

Overall Test Case Results: Passed

Object Test Case TC-O-284
VDOT Implemented: Yes
Std Par Ref 5.11.1.4
OID 1.3.6.1.4.1.1206.4.2.3.9.4.0
Object Name dmsCurrentSpeedLimit
Syntax Access Status
INTEGER (0..255) read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object   Failed - NoSuchName
2 - Set Object to Min. Value   Failed - NoSuchName
3 - Set Object to Max. Value   Failed - NoSuchName
4 - Attempt Write to Read-Only Object   Skipped - Not read only
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 256 Success - did not write greater than Max
7 - Attempt to Set Value < Min. -1 Success - did not write less than Min

Overall Test Case Results: Passed

Object Test Case TC-O-285
VDOT Implemented: Yes
Std Par Ref 5.11.1.5
OID 1.3.6.1.4.1.1206.4.2.3.9.5.0
Object Name watchdogFailureCount
Syntax Access Status
Counter read-only optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 27 Success
2 - Set Object to Min. Value 28 Success
3 - Set Object to Max. Value 29 Success
4 - Attempt Write to Read-Only Object   Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max.   Skipped - not writable
7 - Attempt to Set Value < Min.   Skipped - not writable
8 - Restore Object to Original Value   Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-286
VDOT Implemented: Yes
Std Par Ref 5.11.1.6
OID 1.3.6.1.4.1.1206.4.2.3.9.6.0
Object Name dmsStatDoorOpen
Syntax Access Status
INTEGER (0..255) read-only optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 0 Success
2 - Set Object to Min. Value 0 Success
3 - Set Object to Max. Value 0 Success
4 - Attempt Write to Read-Only Object   Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max.   Skipped - not writable
7 - Attempt to Set Value < Min.   Skipped - not writable
8 - Restore Object to Original Value   Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-287
VDOT Implemented: Yes
Std Par Ref 5.11.2.1.1
OID 1.3.6.1.4.1.1206.4.2.3.9.7.1.0
Object Name shortErrorStatus
Syntax Access Status
INTEGER (0..65535) read-only optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 2148 Success
2 - Set Object to Min. Value 2148 Success
3 - Set Object to Max. Value 2148 Success
4 - Attempt Write to Read-Only Object   Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max.   Skipped - not writable
7 - Attempt to Set Value < Min.   Skipped - not writable
8 - Restore Object to Original Value   Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-288
VDOT Implemented: Yes
Std Par Ref 5.11.2.1.2
OID 1.3.6.1.4.1.1206.4.2.3.9.7.10.0
Object Name controllerErrorStatus
Syntax Access Status
INTEGER (0..255) read-only optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 0 Success
2 - Set Object to Min. Value 0 Success
3 - Set Object to Max. Value 0 Success
4 - Attempt Write to Read-Only Object   Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max.   Skipped - not writable
7 - Attempt to Set Value < Min.   Skipped - not writable
8 - Restore Object to Original Value   Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-289
VDOT Implemented: Yes
Std Par Ref 5.11.2.2.1
OID 1.3.6.1.4.1.1206.4.2.3.9.7.11.0
Object Name dmsPowerStatusMap
Syntax Access Status
OCTET STRING (SIZE (0..64)) read-only optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 01 Success
2 - Set Object to Min. Value 01 Success
3 - Set Object to Max. Value 01 Success
4 - Attempt Write to Read-Only Object 00 Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object 00 Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 00 Skipped - not writable
7 - Attempt to Set Value < Min. 00 Skipped - not writable
8 - Restore Object to Original Value 00 Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-290
VDOT Implemented: Yes
Std Par Ref 5.11.2.2.2
OID 1.3.6.1.4.1.1206.4.2.3.9.7.12.0
Object Name dmsPowerNumRows
Syntax Access Status
INTEGER (0..512) read-only optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 1 Success
2 - Set Object to Min. Value 1 Success
3 - Set Object to Max. Value 1 Success
4 - Attempt Write to Read-Only Object   Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max.   Skipped - not writable
7 - Attempt to Set Value < Min.   Skipped - not writable
8 - Restore Object to Original Value   Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-291
VDOT Implemented: Yes
Std Par Ref 5.11.2.2.3.1
OID 1.3.6.1.4.1.1206.4.2.3.9.7.13.1.1.1
Object Name dmsPowerIndex
Syntax Access Status
INTEGER (1..512) read-only optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 1 Success
2 - Set Object to Min. Value 1 Success
3 - Set Object to Max. Value 1 Success
4 - Attempt Write to Read-Only Object   Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max.   Skipped - not writable
7 - Attempt to Set Value < Min.   Skipped - not writable
8 - Restore Object to Original Value   Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-292
VDOT Implemented: Yes
Std Par Ref 5.11.2.2.3.2
OID 1.3.6.1.4.1.1206.4.2.3.9.7.13.1.2.1
Object Name dmsPowerDescription
Syntax Access Status
DisplayString read-only optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 4C 45 44 20 50 6F 77 65 72 20 73 75 70 70 6C 79 00 00 00 00 Success
2 - Set Object to Min. Value 4C 45 44 20 50 6F 77 65 72 20 73 75 70 70 6C 79 00 00 00 00 Success
3 - Set Object to Max. Value 4C 45 44 20 50 6F 77 65 72 20 73 75 70 70 6C 79 00 00 00 00 Success
4 - Attempt Write to Read-Only Object 00 Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object 00 Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 00 Skipped - not writable
7 - Attempt to Set Value < Min. 00 Skipped - not writable
8 - Restore Object to Original Value 00 Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-293
VDOT Implemented: Yes
Std Par Ref 5.11.2.2.3.3
OID 1.3.6.1.4.1.1206.4.2.3.9.7.13.1.3.1
Object Name dmsPowerMfrStatus
Syntax Access Status
DisplayString (SIZE (0..64)) read-only optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object   Success
2 - Set Object to Min. Value   Success
3 - Set Object to Max. Value   Success
4 - Attempt Write to Read-Only Object 00 Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object 00 Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 00 Skipped - not writable
7 - Attempt to Set Value < Min. 00 Skipped - not writable
8 - Restore Object to Original Value 00 Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-294
VDOT Implemented: Yes
Std Par Ref 5.11.2.2.3.4
OID 1.3.6.1.4.1.1206.4.2.3.9.7.13.1.4.1
Object Name dmsPowerStatus
Syntax Access Status
INTEGER {enumeration} read-only optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 3 (powerFail) Success
2 - Set Object to Min. Value 3 (powerFail) Success
3 - Set Object to Max. Value 3 (powerFail) Success
4 - Attempt Write to Read-Only Object   Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max.   Skipped - not writable
7 - Attempt to Set Value < Min.   Skipped - not writable
8 - Restore Object to Original Value   Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-295
VDOT Implemented: Yes
Std Par Ref 5.11.2.2.3.5
OID 1.3.6.1.4.1.1206.4.2.3.9.7.15.0
Object Name dmsPowerType
Syntax Access Status
INTEGER {enumeration} read-only optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object   Failed - NoSuchName
2 - Set Object to Min. Value   Failed - NoSuchName
3 - Set Object to Max. Value   Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max.   Skipped - not writable
7 - Attempt to Set Value < Min.   Skipped - not writable
8 - Restore Object to Original Value   Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-296
VDOT Implemented: Yes
Std Par Ref 5.11.2.3.1
OID 1.3.6.1.4.1.1206.4.2.3.9.7.8.0
Object Name fanFailures
Syntax Access Status
OCTET STRING (SIZE (0..4)) read-only optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 00 Success
2 - Set Object to Min. Value 00 Success
3 - Set Object to Max. Value 00 Success
4 - Attempt Write to Read-Only Object 00 Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object 00 Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 00 Skipped - not writable
7 - Attempt to Set Value < Min. 00 Skipped - not writable
8 - Restore Object to Original Value 00 Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-297
VDOT Implemented: Yes
Std Par Ref 5.11.2.3.2
OID 1.3.6.1.4.1.1206.4.2.3.9.7.9.0
Object Name fanTestActivation
Syntax Access Status
INTEGER {enumeration} read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 2 (noTest) Success
2 - Set Object to Min. Value 2 (noTest) Success
3 - Set Object to Max. Value 2 (noTest) Success
4 - Attempt Write to Read-Only Object   Skipped - Not read only
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max.   Skipped - no Minimum
7 - Attempt to Set Value < Min.   Skipped - no Minimum
8 - Restore Object to Original Value 2 (noTest) Success

Overall Test Case Results: Passed

Object Test Case TC-O-298
VDOT Implemented: Yes
Std Par Ref 5.11.2.3.3
OID 1.3.6.1.4.1.1206.4.2.3.9.7.14.0
Object Name dmsClimateCtrlStatusMap
Syntax Access Status
OCTET STRING (SIZE (0..64)) read-only optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 00 Success
2 - Set Object to Min. Value 00 Success
3 - Set Object to Max. Value 00 Success
4 - Attempt Write to Read-Only Object 00 Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object 00 Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 00 Skipped - not writable
7 - Attempt to Set Value < Min. 00 Skipped - not writable
8 - Restore Object to Original Value 00 Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-299
VDOT Implemented: Yes
Std Par Ref 5.11.2.3.4
OID 1.3.6.1.4.1.1206.4.2.3.9.7.16.0
Object Name dmsClimateCtrlNumRows
Syntax Access Status
INTEGER (0..512) read-only optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 0 Success
2 - Set Object to Min. Value 0 Success
3 - Set Object to Max. Value 0 Success
4 - Attempt Write to Read-Only Object   Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max.   Skipped - not writable
7 - Attempt to Set Value < Min.   Skipped - not writable
8 - Restore Object to Original Value   Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-300
VDOT Implemented: Yes
Std Par Ref 5.11.2.3.5.1
OID 1.3.6.1.4.1.1206.4.2.3.9.7.17.1.1.1
Object Name dmsClimateCtrlIndex
Syntax Access Status
INTEGER (1..512) read-only optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object   Failed - GenErr
2 - Set Object to Min. Value   Failed - GenErr
3 - Set Object to Max. Value   Failed - GenErr
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max.   Skipped - not writable
7 - Attempt to Set Value < Min.   Skipped - not writable
8 - Restore Object to Original Value   Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-301
VDOT Implemented: Yes
Std Par Ref 5.11.2.3.5.2
OID 1.3.6.1.4.1.1206.4.2.3.9.7.17.1.2.1
Object Name dmsClimateCtrlDescription
Syntax Access Status
DisplayString read-only optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 00 Failed - GenErr
2 - Set Object to Min. Value 00 Failed - GenErr
3 - Set Object to Max. Value 00 Failed - GenErr
4 - Attempt Write to Read-Only Object 00 Failed - GenErr
5 - Attempt Read of Non-Accessible Object 00 Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 00 Skipped - not writable
7 - Attempt to Set Value < Min. 00 Skipped - not writable
8 - Restore Object to Original Value 00 Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-302
VDOT Implemented: Yes
Std Par Ref 5.11.2.3.5.3
OID 1.3.6.1.4.1.1206.4.2.3.9.7.17.1.3.1
Object Name dmsClimateCtrlMfrStatus
Syntax Access Status
DisplayString (SIZE (0..64)) read-only optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 00 Failed - GenErr
2 - Set Object to Min. Value 00 Failed - GenErr
3 - Set Object to Max. Value 00 Failed - GenErr
4 - Attempt Write to Read-Only Object 00 Failed - GenErr
5 - Attempt Read of Non-Accessible Object 00 Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 00 Skipped - not writable
7 - Attempt to Set Value < Min. 00 Skipped - not writable
8 - Restore Object to Original Value 00 Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-303
VDOT Implemented: Yes
Std Par Ref 5.11.2.3.5.4
OID 1.3.6.1.4.1.1206.4.2.3.9.7.17.1.4.1
Object Name dmsClimateCtrlErrorStatus
Syntax Access Status
INTEGER {enumeration} read-only optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object   Failed - GenErr
2 - Set Object to Min. Value   Failed - GenErr
3 - Set Object to Max. Value   Failed - GenErr
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max.   Skipped - not writable
7 - Attempt to Set Value < Min.   Skipped - not writable
8 - Restore Object to Original Value   Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-304
VDOT Implemented: Yes
Std Par Ref 5.11.2.3.5.5
OID 1.3.6.1.4.1.1206.4.2.3.9.7.17.1.5.1
Object Name dmsClimateCtrlOnStatus
Syntax Access Status
INTEGER (0..1) read-only optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object   Failed - GenErr
2 - Set Object to Min. Value   Failed - GenErr
3 - Set Object to Max. Value   Failed - GenErr
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max.   Skipped - not writable
7 - Attempt to Set Value < Min.   Skipped - not writable
8 - Restore Object to Original Value   Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-305
VDOT Implemented: Yes
Std Par Ref 5.11.2.3.5.6
OID 1.3.6.1.4.1.1206.4.2.3.9.7.17.1.6.1
Object Name dmsClimateCtrlTestActivation
Syntax Access Status
INTEGER {enumeration} read-write optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object   Failed - GenErr
2 - Set Object to Min. Value   Failed - GenErr
3 - Set Object to Max. Value   Failed - GenErr
4 - Attempt Write to Read-Only Object   Skipped - Not read only
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max.   Skipped - no Minimum
7 - Attempt to Set Value < Min.   Skipped - no Minimum

Overall Test Case Results: Passed

Object Test Case TC-O-306
VDOT Implemented: Yes
Std Par Ref 5.11.2.3.5.7
OID 1.3.6.1.4.1.1206.4.2.3.9.7.17.1.7.1
Object Name dmsClimateCtrlAbortReason
Syntax Access Status
DisplayString (SIZE (0..64)) write-only optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 00 Failed - GenErr
2 - Set Object to Min. Value 00 Failed - GenErr
3 - Set Object to Max. Value 00 Failed - GenErr
4 - Attempt Write to Read-Only Object 00 Skipped - Not read only
5 - Attempt Read of Non-Accessible Object 00 Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 1 Success - did not write greater than Max
7 - Attempt to Set Value < Min. -1 Success - did not write less than Min
8 - Restore Object to Original Value 00 Failed - GenErr

Overall Test Case Results: Passed

Object Test Case TC-O-307
VDOT Implemented: Yes
Std Par Ref 5.11.2.4.1
OID 1.3.6.1.4.1.1206.4.2.3.9.7.2.0
Object Name pixelFailureTableNumRows
Syntax Access Status
INTEGER (0..65535) read-only optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 1620 Success
2 - Set Object to Min. Value 0 Success
3 - Set Object to Max. Value 0 Success
4 - Attempt Write to Read-Only Object   Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max.   Skipped - not writable
7 - Attempt to Set Value < Min.   Skipped - not writable
8 - Restore Object to Original Value   Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-308
VDOT Implemented: Yes
Std Par Ref 5.11.2.4.2.1
OID 1.3.6.1.4.1.1206.4.2.3.9.7.3.1.1.1.1
Object Name pixelFailureDetectionType
Syntax Access Status
INTEGER {enumeration} read-only optional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 2 (pixelTest) Success
2 - Set Object to Min. Value 0 Success
3 - Set Object to Max. Value 0 Success
4 - Attempt Write to Read-Only Object   Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object   Skipped - Not not-accessible
6 - Attempt to Set Value > Max.   Skipped - not writable
7 - Attempt to Set Value < Min.   Skipped - not writable
8 - Restore Object to Original Value   Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-309
VDOT Implemented: Yes
Std Par Ref 5.11.2.4.2.2
OID1.3.6.1.4.1.1206.4.2.3.9.7.3.1.2.1.1
Object NamepixelFailureIndex
Syntax Access Status
INTEGER (1..65535)read-onlyoptional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object1Success
2 - Set Object to Min. Value1Success
3 - Set Object to Max. Value1Success
4 - Attempt Write to Read-Only Object  Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object  Skipped - Not not-accessible
6 - Attempt to Set Value > Max.  Skipped - not writable
7 - Attempt to Set Value < Min.  Skipped - not writable
8 - Restore Object to Original Value  Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-310
VDOT Implemented: Yes
Std Par Ref 5.11.2.4.2.3
OID1.3.6.1.4.1.1206.4.2.3.9.7.3.1.3.1.1
Object NamepixelFailureXLocation
Syntax Access Status
INTEGER (1..65535)read-onlyoptional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object1Success
2 - Set Object to Min. Value0Success
3 - Set Object to Max. Value0Success
4 - Attempt Write to Read-Only Object  Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object  Skipped - Not not-accessible
6 - Attempt to Set Value > Max.  Skipped - not writable
7 - Attempt to Set Value < Min.  Skipped - not writable
8 - Restore Object to Original Value  Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-311
VDOT Implemented: Yes
Std Par Ref 5.11.2.4.2.4
OID1.3.6.1.4.1.1206.4.2.3.9.7.3.1.4.1.1
Object NamepixelFailureYLocation
Syntax Access Status
INTEGER (1..65535)read-onlyoptional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object1Success
2 - Set Object to Min. Value0Success
3 - Set Object to Max. Value0Success
4 - Attempt Write to Read-Only Object  Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object  Skipped - Not not-accessible
6 - Attempt to Set Value > Max.  Skipped - not writable
7 - Attempt to Set Value < Min.  Skipped - not writable
8 - Restore Object to Original Value  Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-312
VDOT Implemented: Yes
Std Par Ref 5.11.2.4.2.5
OID1.3.6.1.4.1.1206.4.2.3.9.7.3.1.5.1.1
Object NamepixelFailureStatus
Syntax Access Status
INTEGER (0..255)read-onlyoptional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object5Success
2 - Set Object to Min. Value0Success
3 - Set Object to Max. Value0Success
4 - Attempt Write to Read-Only Object  Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object  Skipped - Not not-accessible
6 - Attempt to Set Value > Max.  Skipped - not writable
7 - Attempt to Set Value < Min.  Skipped - not writable
8 - Restore Object to Original Value  Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-313
VDOT Implemented: Yes
Std Par Ref 5.11.2.4.3
OID1.3.6.1.4.1.1206.4.2.3.9.7.4.0
Object NamepixelTestActivation
Syntax Access Status
INTEGER {enumeration}read-writeoptional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object2 (noTest)Success
2 - Set Object to Min. Value2 (noTest)Success
3 - Set Object to Max. Value2 (noTest)Success
4 - Attempt Write to Read-Only Object  Skipped - Not read only
5 - Attempt Read of Non-Accessible Object  Skipped - Not not-accessible
6 - Attempt to Set Value > Max.  Skipped - no Minimum
7 - Attempt to Set Value < Min.  Skipped - no Minimum
8 - Restore Object to Original Value2 (noTest)Success

Overall Test Case Results: Passed

Object Test Case TC-O-314
VDOT Implemented: Yes
Std Par Ref 5.11.2.4.4.2
OID1.3.6.1.4.1.1206.4.2.3.9.7.18.1.2.1
Object NamedmsPixelStatus
Syntax Access Status
OCTET STRING (SIZE(1..400))read-onlyoptional
Test TypeTest ValueTest Results
1 - Read Initial Value of ObjectFF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF ...Success
2 - Set Object to Min. Value00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 ...Success
3 - Set Object to Max. Value00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 ...Success
4 - Attempt Write to Read-Only Object 00Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object 00Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 00Skipped - not writable
7 - Attempt to Set Value < Min. 00Skipped - not writable
8 - Restore Object to Original Value 00Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-315
VDOT Implemented: Yes
Std Par Ref 5.11.2.4.5
OID1.3.6.1.4.1.1206.4.2.3.9.7.18.1.3.1
Object NamedmsPixelFailureTestRows
Syntax Access Status
INTEGER (0..65535)read-onlyoptional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object  Failed - NoSuchName
2 - Set Object to Min. Value  Failed - NoSuchName
3 - Set Object to Max. Value  Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object  Skipped - Not not-accessible
6 - Attempt to Set Value > Max.  Skipped - not writable
7 - Attempt to Set Value < Min.  Skipped - not writable
8 - Restore Object to Original Value  Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-316
VDOT Implemented: Yes
Std Par Ref 5.11.2.4.6
OID1.3.6.1.4.1.1206.4.2.3.9.7.18.1.4.1
Object NamedmsPixelFailureMessageRows
Syntax Access Status
INTEGER (0..65535)read-onlyoptional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object  Failed - NoSuchName
2 - Set Object to Min. Value  Failed - NoSuchName
3 - Set Object to Max. Value  Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object  Skipped - Not not-accessible
6 - Attempt to Set Value > Max.  Skipped - not writable
7 - Attempt to Set Value < Min.  Skipped - not writable
8 - Restore Object to Original Value  Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-317
VDOT Implemented: Yes
Std Par Ref 5.11.2.5.1
OID1.3.6.1.4.1.1206.4.2.3.9.7.5.0
Object NamelampFailureStuckOn
Syntax Access Status
OCTET STRING (SIZE (0..255))read-onlyoptional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 00Failed - NoSuchName
2 - Set Object to Min. Value 00Failed - NoSuchName
3 - Set Object to Max. Value 00Failed - NoSuchName
4 - Attempt Write to Read-Only Object 00Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object 00Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 00Skipped - not writable
7 - Attempt to Set Value < Min. 00Skipped - not writable
8 - Restore Object to Original Value 00Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-318
VDOT Implemented: Yes
Std Par Ref 5.11.2.5.2
OID1.3.6.1.4.1.1206.4.2.3.9.7.6.0
Object NamelampFailureStuckOff
Syntax Access Status
OCTET STRING (SIZE (0..255))read-onlyoptional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 00Failed - NoSuchName
2 - Set Object to Min. Value 00Failed - NoSuchName
3 - Set Object to Max. Value 00Failed - NoSuchName
4 - Attempt Write to Read-Only Object 00Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object 00Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 00Skipped - not writable
7 - Attempt to Set Value < Min. 00Skipped - not writable
8 - Restore Object to Original Value 00Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-319
VDOT Implemented: Yes
Std Par Ref 5.11.2.5.3
OID1.3.6.1.4.1.1206.4.2.3.9.7.7.0
Object NamelampTestActivation
Syntax Access Status
INTEGER {enumeration}read-writeoptional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object  Failed - NoSuchName
2 - Set Object to Min. Value  Failed - NoSuchName
3 - Set Object to Max. Value  Failed - NoSuchName
4 - Attempt Write to Read-Only Object  Skipped - Not read only
5 - Attempt Read of Non-Accessible Object  Skipped - Not not-accessible
6 - Attempt to Set Value > Max.  Skipped - no Minimum
7 - Attempt to Set Value < Min.  Skipped - no Minimum

Overall Test Case Results: Passed

Object Test Case TC-O-320
VDOT Implemented: Yes
Std Par Ref 5.11.2.5.4
OID1.3.6.1.4.1.1206.4.2.3.9.7.23.0
Object NamedmsLampNumRows
Syntax Access Status
INTEGER (0..2040)read-onlyoptional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object  Failed - NoSuchName
2 - Set Object to Min. Value  Failed - NoSuchName
3 - Set Object to Max. Value  Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object  Skipped - Not not-accessible
6 - Attempt to Set Value > Max.  Skipped - not writable
7 - Attempt to Set Value < Min.  Skipped - not writable
8 - Restore Object to Original Value  Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-321
VDOT Implemented: Yes
Std Par Ref 5.11.2.5.5.1
OID1.3.6.1.4.1.1206.4.2.3.9.7.24.1.1.1
Object NamedmsLampIndex
Syntax Access Status
INTEGER (1..2040)read-onlyoptional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object  Failed - NoSuchName
2 - Set Object to Min. Value  Failed - NoSuchName
3 - Set Object to Max. Value  Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object  Skipped - Not not-accessible
6 - Attempt to Set Value > Max.  Skipped - not writable
7 - Attempt to Set Value < Min.  Skipped - not writable
8 - Restore Object to Original Value  Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-322
VDOT Implemented: Yes
Std Par Ref 5.11.2.5.5.2
OID1.3.6.1.4.1.1206.4.2.3.9.7.24.1.2.1
Object NamedmsLampDescription
Syntax Access Status
DisplayStringread-onlyoptional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 00Failed - NoSuchName
2 - Set Object to Min. Value 00Failed - NoSuchName
3 - Set Object to Max. Value 00Failed - NoSuchName
4 - Attempt Write to Read-Only Object 00Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object 00Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 00Skipped - not writable
7 - Attempt to Set Value < Min. 00Skipped - not writable
8 - Restore Object to Original Value 00Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-323
VDOT Implemented: Yes
Std Par Ref 5.11.2.5.5.3
OID1.3.6.1.4.1.1206.4.2.3.9.7.24.1.3.1
Object NamedmsLampMfrStatus
Syntax Access Status
DisplayString (SIZE (0..64))Read-onlyoptional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 00Failed - NoSuchName
2 - Set Object to Min. Value 00Failed - NoSuchName
3 - Set Object to Max. Value 00Failed - NoSuchName
4 - Attempt Write to Read-Only Object 00Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object 00Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 00Skipped - not writable
7 - Attempt to Set Value < Min. 00Skipped - not writable
8 - Restore Object to Original Value 00Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-324
VDOT Implemented: Yes
Std Par Ref 5.11.2.5.5.4
OID1.3.6.1.4.1.1206.4.2.3.9.7.24.1.4.1
Object NamedmsLampStatus
Syntax Access Status
INTEGER {enumeration}read-onlyoptional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object  Failed - NoSuchName
2 - Set Object to Min. Value  Failed - NoSuchName
3 - Set Object to Max. Value  Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object  Skipped - Not not-accessible
6 - Attempt to Set Value > Max.  Skipped - not writable
7 - Attempt to Set Value < Min.  Skipped - not writable
8 - Restore Object to Original Value  Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-325
VDOT Implemented: Yes
Std Par Ref 5.11.2.5.5.5
OID1.3.6.1.4.1.1206.4.2.3.9.7.24.1.5.1
Object NamedmsLampPixelTop
Syntax Access Status
INTEGER (1..65535)read-onlyoptional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object  Failed - NoSuchName
2 - Set Object to Min. Value  Failed - NoSuchName
3 - Set Object to Max. Value  Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object  Skipped - Not not-accessible
6 - Attempt to Set Value > Max.  Skipped - not writable
7 - Attempt to Set Value < Min.  Skipped - not writable
8 - Restore Object to Original Value  Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-326
VDOT Implemented: Yes
Std Par Ref 5.11.2.5.5.6
OID1.3.6.1.4.1.1206.4.2.3.9.7.24.1.6.1
Object NamedmsLampPixelLeft
Syntax Access Status
INTEGER (1..65535)read-onlyoptional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object  Failed - NoSuchName
2 - Set Object to Min. Value  Failed - NoSuchName
3 - Set Object to Max. Value  Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object  Skipped - Not not-accessible
6 - Attempt to Set Value > Max.  Skipped - not writable
7 - Attempt to Set Value < Min.  Skipped - not writable
8 - Restore Object to Original Value  Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-327
VDOT Implemented: Yes
Std Par Ref 5.11.2.5.5.7
OID1.3.6.1.4.1.1206.4.2.3.9.7.24.1.7.1
Object NamedmsLampPixelBottom
Syntax Access Status
INTEGER (1..65535)read-onlyoptional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object  Failed - NoSuchName
2 - Set Object to Min. Value  Failed - NoSuchName
3 - Set Object to Max. Value  Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object  Skipped - Not not-accessible
6 - Attempt to Set Value > Max.  Skipped - not writable
7 - Attempt to Set Value < Min.  Skipped - not writable
8 - Restore Object to Original Value  Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-328
VDOT Implemented: Yes
Std Par Ref 5.11.2.5.5.8
OID1.3.6.1.4.1.1206.4.2.3.9.7.24.1.8.1
Object NamedmsLampPixelRight
Syntax Access Status
INTEGER (1..65535)read-onlyoptional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object  Failed - NoSuchName
2 - Set Object to Min. Value  Failed - NoSuchName
3 - Set Object to Max. Value  Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object  Skipped - Not not-accessible
6 - Attempt to Set Value > Max.  Skipped - not writable
7 - Attempt to Set Value < Min.  Skipped - not writable
8 - Restore Object to Original Value  Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-329
VDOT Implemented: Yes
Std Par Ref 5.11.2.6.1
OID1.3.6.1.4.1.1206.4.2.3.9.7.25.0
Object NamedmsDrumStatusMap
Syntax Access Status
OCTET STRING (SIZE (0..2))read-onlyoptional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 00Failed - NoSuchName
2 - Set Object to Min. Value 00Failed - NoSuchName
3 - Set Object to Max. Value 00Failed - NoSuchName
4 - Attempt Write to Read-Only Object 00Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object 00Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 00Skipped - not writable
7 - Attempt to Set Value < Min. 00Skipped - not writable
8 - Restore Object to Original Value 00Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-330
VDOT Implemented: Yes
Std Par Ref 5.11.2.6.2
OID1.3.6.1.4.1.1206.4.2.3.9.7.26.0
Object NamedmsDrumNumRows
Syntax Access Status
INTEGER (0..16)read-onlyoptional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object  Failed - NoSuchName
2 - Set Object to Min. Value  Failed - NoSuchName
3 - Set Object to Max. Value  Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object  Skipped - Not not-accessible
6 - Attempt to Set Value > Max.  Skipped - not writable
7 - Attempt to Set Value < Min.  Skipped - not writable
8 - Restore Object to Original Value  Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-331
VDOT Implemented: Yes
Std Par Ref 5.11.2.6.3.1
OID1.3.6.1.4.1.1206.4.2.3.9.7.27.1.1.1
Object NamedmsDrumIndex
Syntax Access Status
INTEGER (1..16)read-onlyoptional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object  Failed - NoSuchName
2 - Set Object to Min. Value  Failed - NoSuchName
3 - Set Object to Max. Value  Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object  Skipped - Not not-accessible
6 - Attempt to Set Value > Max.  Skipped - not writable
7 - Attempt to Set Value < Min.  Skipped - not writable
8 - Restore Object to Original Value  Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-332
VDOT Implemented: Yes
Std Par Ref 5.11.2.6.3.2
OID1.3.6.1.4.1.1206.4.2.3.9.7.27.1.2.1
Object NamedmsDrumDescription
Syntax Access Status
DisplayStringread-onlyoptional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 00Failed - NoSuchName
2 - Set Object to Min. Value 00Failed - NoSuchName
3 - Set Object to Max. Value 00Failed - NoSuchName
4 - Attempt Write to Read-Only Object 00Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object 00Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 00Skipped - not writable
7 - Attempt to Set Value < Min. 00Skipped - not writable
8 - Restore Object to Original Value 00Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-333
VDOT Implemented: Yes
Std Par Ref 5.11.2.6.3.3
OID1.3.6.1.4.1.1206.4.2.3.9.7.27.1.3.1
Object NamedmsDrumMfrStatus
Syntax Access Status
DisplayString (SIZE (0..64))read-onlyoptional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 00Failed - NoSuchName
2 - Set Object to Min. Value 00Failed - NoSuchName
3 - Set Object to Max. Value 00Failed - NoSuchName
4 - Attempt Write to Read-Only Object 00Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object 00Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 00Skipped - not writable
7 - Attempt to Set Value < Min. 00Skipped - not writable
8 - Restore Object to Original Value 00Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-334
VDOT Implemented: Yes
Std Par Ref 5.11.2.6.3.4
OID1.3.6.1.4.1.1206.4.2.3.9.7.27.1.4.1
Object NamedmsDrumStatus
Syntax Access Status
INTEGER {enumeration}read-onlyoptional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object  Failed - NoSuchName
2 - Set Object to Min. Value  Failed - NoSuchName
3 - Set Object to Max. Value  Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object  Skipped - Not not-accessible
6 - Attempt to Set Value > Max.  Skipped - not writable
7 - Attempt to Set Value < Min.  Skipped - not writable
8 - Restore Object to Original Value  Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-335
VDOT Implemented: Yes
Std Par Ref 5.11.2.7.1
OID1.3.6.1.4.1.1206.4.2.3.9.7.28.0
Object NamedmsLightSensorStatusMap
Syntax Access Status
OCTET STRING (SIZE (0..2))read-onlyoptional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 07Success
2 - Set Object to Min. Value 07Success
3 - Set Object to Max. Value 07Success
4 - Attempt Write to Read-Only Object 00Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object 00Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 00Skipped - not writable
7 - Attempt to Set Value < Min. 00Skipped - not writable
8 - Restore Object to Original Value 00Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-336
VDOT Implemented: Yes
Std Par Ref 5.11.2.7.2
OID1.3.6.1.4.1.1206.4.2.3.9.7.29.0
Object NamedmsLightSensorNumRows
Syntax Access Status
INTEGER (0..16)read-onlyoptional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object3Success
2 - Set Object to Min. Value3Success
3 - Set Object to Max. Value3Success
4 - Attempt Write to Read-Only Object  Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object  Skipped - Not not-accessible
6 - Attempt to Set Value > Max.  Skipped - not writable
7 - Attempt to Set Value < Min.  Skipped - not writable
8 - Restore Object to Original Value  Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-337
VDOT Implemented: Yes
Std Par Ref 5.11.2.7.3.1
OID1.3.6.1.4.1.1206.4.2.3.9.7.30.1.1.1
Object NamedmsLightSensorIndex
Syntax Access Status
INTEGER (1..16)read-onlyoptional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object1Success
2 - Set Object to Min. Value1Success
3 - Set Object to Max. Value1Success
4 - Attempt Write to Read-Only Object  Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object  Skipped - Not not-accessible
6 - Attempt to Set Value > Max.  Skipped - not writable
7 - Attempt to Set Value < Min.  Skipped - not writable
8 - Restore Object to Original Value  Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-338
VDOT Implemented: Yes
Std Par Ref 5.11.2.7.3.2
OID1.3.6.1.4.1.1206.4.2.3.9.7.30.1.2.1
Object NamedmsLightSensorDescription
Syntax Access Status
DisplayStringread-onlyoptional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object50 68 6F 74 6F 63 65 6C 6C 00 00 00 00 00 00 00 00 00 00 00 Success
2 - Set Object to Min. Value50 68 6F 74 6F 63 65 6C 6C 00 00 00 00 00 00 00 00 00 00 00 Success
3 - Set Object to Max. Value50 68 6F 74 6F 63 65 6C 6C 00 00 00 00 00 00 00 00 00 00 00 Success
4 - Attempt Write to Read-Only Object 00Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object 00Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 00Skipped - not writable
7 - Attempt to Set Value < Min. 00Skipped - not writable
8 - Restore Object to Original Value 00Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-339
VDOT Implemented: Yes
Std Par Ref 5.11.2.7.3.3
OID1.3.6.1.4.1.1206.4.2.3.9.7.30.1.3.1
Object NamedmsLightSensorCurrentReading
Syntax Access Status
INTEGER (0..65535)read-onlyoptional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object0Success
2 - Set Object to Min. Value0Success
3 - Set Object to Max. Value0Success
4 - Attempt Write to Read-Only Object  Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object  Skipped - Not not-accessible
6 - Attempt to Set Value > Max.  Skipped - not writable
7 - Attempt to Set Value < Min.  Skipped - not writable
8 - Restore Object to Original Value  Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-340
VDOT Implemented: Yes
Std Par Ref 5.11.2.7.3.4
OID1.3.6.1.4.1.1206.4.2.3.9.7.30.1.4.1
Object NamedmsLightSensorStatus
Syntax Access Status
INTEGER {enumeration}read-onlyoptional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object3 (fail)Success
2 - Set Object to Min. Value3 (fail)Success
3 - Set Object to Max. Value3 (fail)Success
4 - Attempt Write to Read-Only Object  Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object  Skipped - Not not-accessible
6 - Attempt to Set Value > Max.  Skipped - not writable
7 - Attempt to Set Value < Min.  Skipped - not writable
8 - Restore Object to Original Value  Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-341
VDOT Implemented: Yes
Std Par Ref 5.11.2.8.1
OID1.3.6.1.4.1.1206.4.2.3.9.7.31.0
Object NamedmsHumiditySensorStatusMap
Syntax Access Status
OCTET STRING (SIZE (0..2))read-onlyoptional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 00Success
2 - Set Object to Min. Value 00Success
3 - Set Object to Max. Value 00Success
4 - Attempt Write to Read-Only Object 00Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object 00Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 00Skipped - not writable
7 - Attempt to Set Value < Min. 00Skipped - not writable
8 - Restore Object to Original Value 00Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-342
VDOT Implemented: Yes
Std Par Ref 5.11.2.8.2
OID1.3.6.1.4.1.1206.4.2.3.9.7.32.0
Object NamedmsHumiditySensorNumRows
Syntax Access Status
SEQUENCE OF DmsHumiditySensorStatusEntrynot-accessibleoptional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object0Success
2 - Set Object to Min. Value0Success
3 - Set Object to Max. Value0Success
4 - Attempt Write to Read-Only Object  Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object  Skipped - Not not-accessible
6 - Attempt to Set Value > Max.  Skipped - not writable
7 - Attempt to Set Value < Min.  Skipped - not writable
8 - Restore Object to Original Value  Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-343
VDOT Implemented: Yes
Std Par Ref 5.11.2.8.2.1
OID1.3.6.1.4.1.1206.4.2.3.9.7.33.1.1.1
Object NamedmsHumiditySensorIndex
Syntax Access Status
INTEGER (1..16)read-onlyoptional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object  Failed - GenErr
2 - Set Object to Min. Value  Failed - GenErr
3 - Set Object to Max. Value  Failed - GenErr
5 - Attempt Read of Non-Accessible Object  Skipped - Not not-accessible
6 - Attempt to Set Value > Max.  Skipped - not writable
7 - Attempt to Set Value < Min.  Skipped - not writable
8 - Restore Object to Original Value  Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-344
VDOT Implemented: Yes
Std Par Ref 5.11.2.8.2.2
OID1.3.6.1.4.1.1206.4.2.3.9.7.33.1.2.1
Object NamedmsHumiditySensorDescription
Syntax Access Status
DisplayStringread-onlyoptional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 00Failed - GenErr
2 - Set Object to Min. Value 00Failed - GenErr
3 - Set Object to Max. Value 00Failed - GenErr
4 - Attempt Write to Read-Only Object 00Failed - GenErr
5 - Attempt Read of Non-Accessible Object 00Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 00Skipped - not writable
7 - Attempt to Set Value < Min. 00Skipped - not writable
8 - Restore Object to Original Value 00Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-345
VDOT Implemented: Yes
Std Par Ref 5.11.2.8.2.3
OID1.3.6.1.4.1.1206.4.2.3.9.7.33.1.3.1
Object NamedmsHumiditySensorCurrentReading
Syntax Access Status
INTEGER (0..100)read-onlyoptional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object  Failed - GenErr
2 - Set Object to Min. Value  Failed - GenErr
3 - Set Object to Max. Value  Failed - GenErr
5 - Attempt Read of Non-Accessible Object  Skipped - Not not-accessible
6 - Attempt to Set Value > Max.  Skipped - not writable
7 - Attempt to Set Value < Min.  Skipped - not writable
8 - Restore Object to Original Value  Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-346
VDOT Implemented: Yes
Std Par Ref 5.11.2.8.2.4
OID1.3.6.1.4.1.1206.4.2.3.9.7.33.1.4.1
Object NamedmsHumiditySensorStatus
Syntax Access Status
INTEGER {enumeration}read-onlyoptional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object  Failed - GenErr
2 - Set Object to Min. Value  Failed - GenErr
3 - Set Object to Max. Value  Failed - GenErr
5 - Attempt Read of Non-Accessible Object  Skipped - Not not-accessible
6 - Attempt to Set Value > Max.  Skipped - not writable
7 - Attempt to Set Value < Min.  Skipped - not writable
8 - Restore Object to Original Value  Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-347
VDOT Implemented: Yes
Std Par Ref 5.11.2.9.1
OID1.3.6.1.4.1.1206.4.2.3.9.7.34.0
Object NamedmsTempSensorStatusMap
Syntax Access Status
OCTET STRING (SIZE (0..2))read-onlyoptional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 01Success
2 - Set Object to Min. Value 01Success
3 - Set Object to Max. Value 01Success
4 - Attempt Write to Read-Only Object 00Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object 00Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 00Skipped - not writable
7 - Attempt to Set Value < Min. 00Skipped - not writable
8 - Restore Object to Original Value 00Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-348
VDOT Implemented: Yes
Std Par Ref 5.11.2.9.2
OID1.3.6.1.4.1.1206.4.2.3.9.7.35.0
Object NamedmsTempSensorNumRows
Syntax Access Status
INTEGER (0..16)read-onlyoptional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object1Success
2 - Set Object to Min. Value1Success
3 - Set Object to Max. Value1Success
4 - Attempt Write to Read-Only Object  Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object  Skipped - Not not-accessible
6 - Attempt to Set Value > Max.  Skipped - not writable
7 - Attempt to Set Value < Min.  Skipped - not writable
8 - Restore Object to Original Value  Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-349
VDOT Implemented: Yes
Std Par Ref 5.11.2.9.3.1
OID1.3.6.1.4.1.1206.4.2.3.9.7.36.1.1.1
Object NamedmsTempSensorIndex
Syntax Access Status
INTEGER (1..16)read-onlyoptional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object1Success
2 - Set Object to Min. Value1Success
3 - Set Object to Max. Value1Success
4 - Attempt Write to Read-Only Object  Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object  Skipped - Not not-accessible
6 - Attempt to Set Value > Max.  Skipped - not writable
7 - Attempt to Set Value < Min.  Skipped - not writable
8 - Restore Object to Original Value  Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-350
VDOT Implemented: Yes
Std Par Ref 5.11.2.9.3.2
OID1.3.6.1.4.1.1206.4.2.3.9.7.36.1.2.1
Object NamedmsTempSensorDescription
Syntax Access Status
DisplayStringread-onlyoptional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object54 65 6D 70 65 72 61 74 75 72 65 20 73 65 6E 73 6F 72 00 00 Success
2 - Set Object to Min. Value54 65 6D 70 65 72 61 74 75 72 65 20 73 65 6E 73 6F 72 00 00 Success
3 - Set Object to Max. Value54 65 6D 70 65 72 61 74 75 72 65 20 73 65 6E 73 6F 72 00 00 Success
4 - Attempt Write to Read-Only Object 00Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object 00Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 00Skipped - not writable
7 - Attempt to Set Value < Min. 00Skipped - not writable
8 - Restore Object to Original Value 00Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-351
VDOT Implemented: Yes
Std Par Ref 5.11.2.9.3.3
OID1.3.6.1.4.1.1206.4.2.3.9.7.36.1.3.1
Object NamedmsTempSensorCurrentReading
Syntax Access Status
INTEGER (-128..127)read-onlyoptional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object0Success
2 - Set Object to Min. Value0Success
3 - Set Object to Max. Value0Success
4 - Attempt Write to Read-Only Object  Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object  Skipped - Not not-accessible
6 - Attempt to Set Value > Max.  Skipped - not writable
7 - Attempt to Set Value < Min.  Skipped - not writable
8 - Restore Object to Original Value  Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-352
VDOT Implemented: Yes
Std Par Ref 5.11.2.9.3.4
OID1.3.6.1.4.1.1206.4.2.3.9.7.36.1.4.1
Object NamedmsTempSensorHighWarningTem
Syntax Access Status
INTEGER (-128..127)read-onlyoptional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object55Success
2 - Set Object to Min. Value55Success
3 - Set Object to Max. Value55Success
4 - Attempt Write to Read-Only Object  Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object  Skipped - Not not-accessible
6 - Attempt to Set Value > Max.  Skipped - not writable
7 - Attempt to Set Value < Min.  Skipped - not writable
8 - Restore Object to Original Value  Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-353
VDOT Implemented: Yes
Std Par Ref 5.11.2.9.3.5
OID1.3.6.1.4.1.1206.4.2.3.9.7.36.1.5.1
Object NamedmsTempSensorLowWarningTemp
Syntax Access Status
INTEGER (-128..127)read-onlyoptional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object-128Success
2 - Set Object to Min. Value-128Success
3 - Set Object to Max. Value-128Success
4 - Attempt Write to Read-Only Object  Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object  Skipped - Not not-accessible
6 - Attempt to Set Value > Max.  Skipped - not writable
7 - Attempt to Set Value < Min.  Skipped - not writable
8 - Restore Object to Original Value  Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-354
VDOT Implemented: Yes
Std Par Ref 5.11.2.9.3.6
OID1.3.6.1.4.1.1206.4.2.3.9.7.36.1.6.1
Object NamedmsTempSensorHighCriticalTemp
Syntax Access Status
INTEGER (-128..127)read-onlyoptional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object60Success
2 - Set Object to Min. Value60Success
3 - Set Object to Max. Value60Success
4 - Attempt Write to Read-Only Object  Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object  Skipped - Not not-accessible
6 - Attempt to Set Value > Max.  Skipped - not writable
7 - Attempt to Set Value < Min.  Skipped - not writable
8 - Restore Object to Original Value  Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-355
VDOT Implemented: Yes
Std Par Ref 5.11.2.9.3.7
OID1.3.6.1.4.1.1206.4.2.3.9.7.36.1.7.1
Object NamedmsTempSensorLowCriticalTempe
Syntax Access Status
INTEGER (-128..127)read-onlyoptional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object-128Success
2 - Set Object to Min. Value-128Success
3 - Set Object to Max. Value-128Success
4 - Attempt Write to Read-Only Object  Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object  Skipped - Not not-accessible
6 - Attempt to Set Value > Max.  Skipped - not writable
7 - Attempt to Set Value < Min.  Skipped - not writable
8 - Restore Object to Original Value  Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-356
VDOT Implemented: Yes
Std Par Ref 5.11.2.9.3.8
OID1.3.6.1.4.1.1206.4.2.3.9.7.36.1.8.1
Object NamedmsTempSensorStatus
Syntax Access Status
INTEGER {enumeration}read-onlyoptional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object3 (fail)Success
2 - Set Object to Min. Value3 (fail)Success
3 - Set Object to Max. Value3 (fail)Success
4 - Attempt Write to Read-Only Object  Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object  Skipped - Not not-accessible
6 - Attempt to Set Value > Max.  Skipped - not writable
7 - Attempt to Set Value < Min.  Skipped - not writable
8 - Restore Object to Original Value  Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-357
VDOT Implemented: Yes
Std Par Ref 5.11.3.1
OID1.3.6.1.4.1.1206.4.2.3.9.8.1.0
Object NamesignVolts
Syntax Access Status
INTEGER (0..65535)read-onlydeprectated
Test TypeTest ValueTest Results
1 - Read Initial Value of Object  Failed - NoSuchName
2 - Set Object to Min. Value  Failed - NoSuchName
3 - Set Object to Max. Value  Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object  Skipped - Not not-accessible
6 - Attempt to Set Value > Max.  Skipped - not writable
7 - Attempt to Set Value < Min.  Skipped - not writable
8 - Restore Object to Original Value  Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-358
VDOT Implemented: Yes
Std Par Ref 5.11.3.2
OID1.3.6.1.4.1.1206.4.2.3.9.8.2.0
Object NamelowFuelThreshold
Syntax Access Status
INTEGER (0..100)read-writedeprectated
Test TypeTest ValueTest Results
1 - Read Initial Value of Object  Failed - NoSuchName
2 - Set Object to Min. Value  Failed - NoSuchName
3 - Set Object to Max. Value  Failed - NoSuchName
4 - Attempt Write to Read-Only Object  Skipped - Not read only
5 - Attempt Read of Non-Accessible Object  Skipped - Not not-accessible
6 - Attempt to Set Value > Max.101Success - did not write greater than Max
7 - Attempt to Set Value < Min.-1Success - did not write less than Min

Overall Test Case Results: Passed

Object Test Case TC-O-359
VDOT Implemented: Yes
Std Par Ref 5.11.3.3
OID1.3.6.1.4.1.1206.4.2.3.9.8.3.0
Object NamefuelLevel
Syntax Access Status
INTEGER (0..100)read-onlydeprectated
Test TypeTest ValueTest Results
1 - Read Initial Value of Object  Failed - NoSuchName
2 - Set Object to Min. Value  Failed - NoSuchName
3 - Set Object to Max. Value  Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object  Skipped - Not not-accessible
6 - Attempt to Set Value > Max.  Skipped - not writable
7 - Attempt to Set Value < Min.  Skipped - not writable
8 - Restore Object to Original Value  Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-360
VDOT Implemented: Yes
Std Par Ref 5.11.3.4
OID1.3.6.1.4.1.1206.4.2.3.9.8.4.0
Object NameengineRPM
Syntax Access Status
INTEGER (0..255)read-onlydeprectated
Test TypeTest ValueTest Results
1 - Read Initial Value of Object  Failed - NoSuchName
2 - Set Object to Min. Value  Failed - NoSuchName
3 - Set Object to Max. Value  Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object  Skipped - Not not-accessible
6 - Attempt to Set Value > Max.  Skipped - not writable
7 - Attempt to Set Value < Min.  Skipped - not writable
8 - Restore Object to Original Value  Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-361
VDOT Implemented: Yes
Std Par Ref 5.11.3.5
OID1.3.6.1.4.1.1206.4.2.3.9.8.5.0
Object NamelineVolts
Syntax Access Status
INTEGER (0..255)read-onlydeprectated
Test TypeTest ValueTest Results
1 - Read Initial Value of Object  Failed - NoSuchName
2 - Set Object to Min. Value  Failed - NoSuchName
3 - Set Object to Max. Value  Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object  Skipped - Not not-accessible
6 - Attempt to Set Value > Max.  Skipped - not writable
7 - Attempt to Set Value < Min.  Skipped - not writable
8 - Restore Object to Original Value  Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-362
VDOT Implemented: Yes
Std Par Ref 5.11.3.6
OID1.3.6.1.4.1.1206.4.2.3.9.8.6.0
Object NamepowerSource
Syntax Access Status
INTEGER {enumeration}read-onlyoptional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object4 (acLine)Success
2 - Set Object to Min. Value4 (acLine)Success
3 - Set Object to Max. Value4 (acLine)Success
4 - Attempt Write to Read-Only Object  Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object  Skipped - Not not-accessible
6 - Attempt to Set Value > Max.  Skipped - not writable
7 - Attempt to Set Value < Min.  Skipped - not writable
8 - Restore Object to Original Value  Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-363
VDOT Implemented: Yes
Std Par Ref 5.11.4.1
OID1.3.6.1.4.1.1206.4.2.3.9.9.1.0
Object NametempMinCtrlCabinet
Syntax Access Status
INTEGER (-128..127)read-onlyoptional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object34Success
2 - Set Object to Min. Value34Success
3 - Set Object to Max. Value34Success
4 - Attempt Write to Read-Only Object  Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object  Skipped - Not not-accessible
6 - Attempt to Set Value > Max.  Skipped - not writable
7 - Attempt to Set Value < Min.  Skipped - not writable
8 - Restore Object to Original Value  Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-364
VDOT Implemented: Yes
Std Par Ref 5.11.4.2
OID1.3.6.1.4.1.1206.4.2.3.9.9.2.0
Object NametempMaxCtrlCabinet
Syntax Access Status
INTEGER (-128..127)read-onlyoptional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object34Success
2 - Set Object to Min. Value34Success
3 - Set Object to Max. Value34Success
4 - Attempt Write to Read-Only Object  Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object  Skipped - Not not-accessible
6 - Attempt to Set Value > Max.  Skipped - not writable
7 - Attempt to Set Value < Min.  Skipped - not writable
8 - Restore Object to Original Value  Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-365
VDOT Implemented: Yes
Std Par Ref 5.11.4.3
OID1.3.6.1.4.1.1206.4.2.3.9.9.3.0
Object NametempMinAmbient
Syntax Access Status
INTEGER (-128..127)read-onlyoptional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object0Success
2 - Set Object to Min. Value0Success
3 - Set Object to Max. Value0Success
4 - Attempt Write to Read-Only Object  Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object  Skipped - Not not-accessible
6 - Attempt to Set Value > Max.  Skipped - not writable
7 - Attempt to Set Value < Min.  Skipped - not writable
8 - Restore Object to Original Value  Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-366
VDOT Implemented: Yes
Std Par Ref 5.11.4.4
OID1.3.6.1.4.1.1206.4.2.3.9.9.4.0
Object NametempMaxAmbient
Syntax Access Status
INTEGER (-128..127)read-onlyoptional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object0Success
2 - Set Object to Min. Value0Success
3 - Set Object to Max. Value0Success
4 - Attempt Write to Read-Only Object  Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object  Skipped - Not not-accessible
6 - Attempt to Set Value > Max.  Skipped - not writable
7 - Attempt to Set Value < Min.  Skipped - not writable
8 - Restore Object to Original Value  Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-367
VDOT Implemented: Yes
Std Par Ref 5.11.4.5
OID1.3.6.1.4.1.1206.4.2.3.9.9.5.0
Object NametempMinSignHousing
Syntax Access Status
INTEGER (-128..127)read-onlyoptional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object0Success
2 - Set Object to Min. Value0Success
3 - Set Object to Max. Value0Success
4 - Attempt Write to Read-Only Object  Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object  Skipped - Not not-accessible
6 - Attempt to Set Value > Max.  Skipped - not writable
7 - Attempt to Set Value < Min.  Skipped - not writable
8 - Restore Object to Original Value  Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-368
VDOT Implemented: Yes
Std Par Ref 5.11.4.6
OID1.3.6.1.4.1.1206.4.2.3.9.9.6.0
Object NametempMaxSignHousing
Syntax Access Status
INTEGER (-128..127)read-onlyoptional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object0Success
2 - Set Object to Min. Value0Success
3 - Set Object to Max. Value0Success
4 - Attempt Write to Read-Only Object  Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object  Skipped - Not not-accessible
6 - Attempt to Set Value > Max.  Skipped - not writable
7 - Attempt to Set Value < Min.  Skipped - not writable
8 - Restore Object to Original Value  Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-369
VDOT Implemented: Yes
Std Par Ref 5.11.4.7
OID1.3.6.1.4.1.1206.4.2.3.9.9.7.0
Object NametempSensorWarningMap
Syntax Access Status
OCTET STRING (SIZE (0..2))read-onlyoptional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 00Success
2 - Set Object to Min. Value 00Success
3 - Set Object to Max. Value 00Success
4 - Attempt Write to Read-Only Object 00Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object 00Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 00Skipped - not writable
7 - Attempt to Set Value < Min. 00Skipped - not writable
8 - Restore Object to Original Value 00Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-370
VDOT Implemented: Yes
Std Par Ref 5.11.4.8
OID1.3.6.1.4.1.1206.4.2.3.9.9.8.0
Object NametempSensorCriticalTempMap
Syntax Access Status
OCTET STRING (SIZE (0..2))read-onlyoptional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 00Success
2 - Set Object to Min. Value 00Success
3 - Set Object to Max. Value 00Success
4 - Attempt Write to Read-Only Object 00Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object 00Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 00Skipped - not writable
7 - Attempt to Set Value < Min. 00Skipped - not writable
8 - Restore Object to Original Value 00Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-371
VDOT Implemented: Yes
Std Par Ref 5.12.1
OID1.3.6.1.4.1.1206.4.2.3.10.1.0
Object NamedmsGraphicMaxEntries
Syntax Access Status
INTEGER (0..255)read-onlyoptional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object32Success
2 - Set Object to Min. Value32Success
3 - Set Object to Max. Value32Success
4 - Attempt Write to Read-Only Object  Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object  Skipped - Not not-accessible
6 - Attempt to Set Value > Max.  Skipped - not writable
7 - Attempt to Set Value < Min.  Skipped - not writable
8 - Restore Object to Original Value  Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-372
VDOT Implemented: Yes
Std Par Ref 5.12.2
OID1.3.6.1.4.1.1206.4.2.3.10.2.0
Object NamedmsGraphicNumEntries
Syntax Access Status
INTEGER (0..255)read-onlyoptional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object0Success
2 - Set Object to Min. Value0Success
3 - Set Object to Max. Value0Success
4 - Attempt Write to Read-Only Object  Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object  Skipped - Not not-accessible
6 - Attempt to Set Value > Max.  Skipped - not writable
7 - Attempt to Set Value < Min.  Skipped - not writable
8 - Restore Object to Original Value  Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-373
VDOT Implemented: Yes
Std Par Ref 5.12.3
OID1.3.6.1.4.1.1206.4.2.3.10.3.0
Object NamedmsGraphicVertSpacing
Syntax Access Status
INTEGER (0..255)read-writeoptional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object0Success
2 - Set Object to Min. Value0Success
3 - Set Object to Max. Value255Success
4 - Attempt Write to Read-Only Object  Skipped - Not read only
5 - Attempt Read of Non-Accessible Object  Skipped - Not not-accessible
6 - Attempt to Set Value > Max.256Success - did not write greater than Max
7 - Attempt to Set Value < Min.-1Failed - wrote less than Min
8 - Restore Object to Original Value0Success

Overall Test Case Results: Passed

Object Test Case TC-O-374
VDOT Implemented: Yes
Std Par Ref 5.12.4
OID1.3.6.1.4.1.1206.4.2.3.10.4.0
Object NamedmsGraphicHorzSpacing
Syntax Access Status
INTEGER (0..255)read-writeoptional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object0Success
2 - Set Object to Min. Value0Success
3 - Set Object to Max. Value255Success
4 - Attempt Write to Read-Only Object  Skipped - Not read only
5 - Attempt Read of Non-Accessible Object  Skipped - Not not-accessible
6 - Attempt to Set Value > Max.256Success - did not write greater than Max
7 - Attempt to Set Value < Min.-1Failed - wrote less than Min
8 - Restore Object to Original Value0Success

Overall Test Case Results: Passed

Object Test Case TC-O-375
VDOT Implemented: Yes
Std Par Ref 5.12.5
OID1.3.6.1.4.1.1206.4.2.3.10.5.0
Object NamedmsGraphicMaxSize
Syntax Access Status
INTEGER (0..65535)read-onlyoptional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object203Success
2 - Set Object to Min. Value203Success
3 - Set Object to Max. Value203Success
4 - Attempt Write to Read-Only Object  Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object  Skipped - Not not-accessible
6 - Attempt to Set Value > Max.  Skipped - not writable
7 - Attempt to Set Value < Min.  Skipped - not writable
8 - Restore Object to Original Value  Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-376
VDOT Implemented: Yes
Std Par Ref 5.12.6
OID1.3.6.1.4.1.1206.4.2.3.10.6.0
Object NameavailableGraphicMemory
Syntax Access Status
Counterread-onlyoptional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object6496Success
2 - Set Object to Min. Value6496Success
3 - Set Object to Max. Value6496Success
4 - Attempt Write to Read-Only Object  Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object  Skipped - Not not-accessible
6 - Attempt to Set Value > Max.  Skipped - not writable
7 - Attempt to Set Value < Min.  Skipped - not writable
8 - Restore Object to Original Value  Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-377
VDOT Implemented: Yes
Std Par Ref 5.12.7
OID1.3.6.1.4.1.1206.4.2.3.10.7.0
Object NamedmsGraphicBlockSize
Syntax Access Status
INTEGER (0..65535)read-onlyoptional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object203Success
2 - Set Object to Min. Value203Success
3 - Set Object to Max. Value203Success
4 - Attempt Write to Read-Only Object  Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object  Skipped - Not not-accessible
6 - Attempt to Set Value > Max.  Skipped - not writable
7 - Attempt to Set Value < Min.  Skipped - not writable
8 - Restore Object to Original Value  Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-378
VDOT Implemented: Yes
Std Par Ref 5.12.8.1
OID1.3.6.1.4.1.1206.4.2.3.10.8.1.1.1
Object NamedmsGraphicIndex
Syntax Access Status
INTEGER (1..255)read-onlyoptional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object1Success
2 - Set Object to Min. Value1Success
3 - Set Object to Max. Value1Success
4 - Attempt Write to Read-Only Object  Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object  Skipped - Not not-accessible
6 - Attempt to Set Value > Max.  Skipped - not writable
7 - Attempt to Set Value < Min.  Skipped - not writable
8 - Restore Object to Original Value  Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-379
VDOT Implemented: Yes
Std Par Ref 5.12.8.2
OID1.3.6.1.4.1.1206.4.2.3.10.8.1.2.1
Object NamedmsGraphicNumber
Syntax Access Status
INTEGER (1..255)read-writeoptional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object0Success
2 - Set Object to Min. Value0Success
3 - Set Object to Max. Value0Success
4 - Attempt Write to Read-Only Object  Skipped - Not read only
5 - Attempt Read of Non-Accessible Object  Skipped - Not not-accessible
6 - Attempt to Set Value > Max.256Success - did not write greater than Max
7 - Attempt to Set Value < Min.0Success - did not write less than Min
8 - Restore Object to Original Value  Failed - BadValue

Overall Test Case Results: Passed

Object Test Case TC-O-380
VDOT Implemented: Yes
Std Par Ref 5.12.8.3
OID1.3.6.1.4.1.1206.4.2.3.10.8.1.3.1
Object NamedmsGraphicName
Syntax Access Status
DisplayString (SIZE (0..64))read-writeoptional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object  Success
2 - Set Object to Min. Value  Success
3 - Set Object to Max. Value  Success
4 - Attempt Write to Read-Only Object 00Skipped - Not read only
5 - Attempt Read of Non-Accessible Object 00Skipped - Not not-accessible
6 - Attempt to Set Value > Max.1Success - did not write greater than Max
7 - Attempt to Set Value < Min.-1Success - did not write less than Min
8 - Restore Object to Original Value 00Failed - GenErr

Overall Test Case Results: Passed

Object Test Case TC-O-381
VDOT Implemented: Yes
Std Par Ref 5.12.8.4
OID1.3.6.1.4.1.1206.4.2.3.10.8.1.4.1
Object NamedmsGraphicHeight
Syntax Access Status
INTEGER (1..255)read-writeoptional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object0Success
2 - Set Object to Min. Value0Success
3 - Set Object to Max. Value0Success
4 - Attempt Write to Read-Only Object  Skipped - Not read only
5 - Attempt Read of Non-Accessible Object  Skipped - Not not-accessible
6 - Attempt to Set Value > Max.256Success - did not write greater than Max
7 - Attempt to Set Value < Min.0Success - did not write less than Min
8 - Restore Object to Original Value  Failed - GenErr

Overall Test Case Results: Passed

Object Test Case TC-O-382
VDOT Implemented: Yes
Std Par Ref 5.12.8.5
OID1.3.6.1.4.1.1206.4.2.3.10.8.1.5.1
Object NamedmsGraphicWidth
Syntax Access Status
INTEGER (1..65535)read-writeoptional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object0Success
2 - Set Object to Min. Value0Success
3 - Set Object to Max. Value0Success
4 - Attempt Write to Read-Only Object  Skipped - Not read only
5 - Attempt Read of Non-Accessible Object  Skipped - Not not-accessible
6 - Attempt to Set Value > Max.65536Success - did not write greater than Max
7 - Attempt to Set Value < Min.0Success - did not write less than Min
8 - Restore Object to Original Value  Failed - BadValue

Overall Test Case Results: Passed

Object Test Case TC-O-383
VDOT Implemented: Yes
Std Par Ref 5.12.8.6
OID1.3.6.1.4.1.1206.4.2.3.10.8.1.6.1
Object NamedmsGraphicType
Syntax Access Status
INTEGER {enumeration}read-writeoptional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object0Success
2 - Set Object to Min. Value0Success
3 - Set Object to Max. Value0Success
4 - Attempt Write to Read-Only Object  Skipped - Not read only
5 - Attempt Read of Non-Accessible Object  Skipped - Not not-accessible
6 - Attempt to Set Value > Max.  Skipped - no Minimum
7 - Attempt to Set Value < Min.  Skipped - no Minimum
8 - Restore Object to Original Value  Failed - BadValue

Overall Test Case Results: Passed

Object Test Case TC-O-384
VDOT Implemented: Yes
Std Par Ref 5.12.8.7
OID1.3.6.1.4.1.1206.4.2.3.10.8.1.7.1
Object NamedmsGraphicID
Syntax Access Status
INTEGER (0..65535)read-onlyoptional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object0Success
2 - Set Object to Min. Value0Success
3 - Set Object to Max. Value0Success
4 - Attempt Write to Read-Only Object  Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object  Skipped - Not not-accessible
6 - Attempt to Set Value > Max.  Skipped - not writable
7 - Attempt to Set Value < Min.  Skipped - not writable
8 - Restore Object to Original Value  Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-385
VDOT Implemented: Yes
Std Par Ref 5.12.8.8
OID1.3.6.1.4.1.1206.4.2.3.10.8.1.8.1
Object NamedmsGraphicTransparentEnabled
Syntax Access Status
INTEGER (0..1)read-writeoptional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object0Success
2 - Set Object to Min. Value0Success
3 - Set Object to Max. Value0Success
4 - Attempt Write to Read-Only Object  Skipped - Not read only
5 - Attempt Read of Non-Accessible Object  Skipped - Not not-accessible
6 - Attempt to Set Value > Max.2Success - did not write greater than Max
7 - Attempt to Set Value < Min.-1Success - did not write less than Min
8 - Restore Object to Original Value  Failed - GenErr

Overall Test Case Results: Passed

Object Test Case TC-O-386
VDOT Implemented: Yes
Std Par Ref 5.12.8.9
OID1.3.6.1.4.1.1206.4.2.3.10.8.1.9.1
Object NamedmsGraphicTransparentColor
Syntax Access Status
OCTET STRING (SIZE(1 | 3))read-writeoptional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object 00Success
2 - Set Object to Min. Value 00Success
3 - Set Object to Max. Value 00Success
4 - Attempt Write to Read-Only Object 00Skipped - Not read only
5 - Attempt Read of Non-Accessible Object 00Skipped - Not not-accessible
6 - Attempt to Set Value > Max.1Success - did not write greater than Max
7 - Attempt to Set Value < Min.-1Success - did not write less than Min
8 - Restore Object to Original Value 00Failed - GenErr

Overall Test Case Results: Passed

Object Test Case TC-O-387
VDOT Implemented: Yes
Std Par Ref 5.12.8.10
OID1.3.6.1.4.1.1206.4.2.3.10.8.1.10.1
Object NamedmsGraphicStatus
Syntax Access Status
INTEGER {enumeration}read-writeoptional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object1 (notUsed)Success
2 - Set Object to Min. Value1 (notUsed)Success
3 - Set Object to Max. Value1 (notUsed)Success
4 - Attempt Write to Read-Only Object  Skipped - Not read only
5 - Attempt Read of Non-Accessible Object  Skipped - Not not-accessible
6 - Attempt to Set Value > Max.  Skipped - no Minimum
7 - Attempt to Set Value < Min.  Skipped - no Minimum
8 - Restore Object to Original Value  Failed - BadValue

Overall Test Case Results: Passed

Object Test Case TC-O-388
VDOT Implemented: Yes
Std Par Ref 5.12.9.1
OID1.3.6.1.4.1.1206.4.2.3.10.9.1.1.1.1
Object NamedmsGraphicBitmapIndex
Syntax Access Status
INTEGER (1..255)read-onlyoptional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object1Success
2 - Set Object to Min. Value1Success
3 - Set Object to Max. Value1Success
4 - Attempt Write to Read-Only Object  Failed - NoSuchName
5 - Attempt Read of Non-Accessible Object  Skipped - Not not-accessible
6 - Attempt to Set Value > Max.  Skipped - not writable
7 - Attempt to Set Value < Min.  Skipped - not writable
8 - Restore Object to Original Value  Skipped - Not writable

Overall Test Case Results: Passed

Object Test Case TC-O-389
VDOT Implemented: Yes
Std Par Ref 5.12.9.2
OID1.3.6.1.4.1.1206.4.2.3.10.9.1.2.1.1
Object NamedmsGraphicBlockNumber
Syntax Access Status
INTEGER (1..255)read-writeoptional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object0Success
2 - Set Object to Min. Value0Success
3 - Set Object to Max. Value0Success
4 - Attempt Write to Read-Only Object  Skipped - Not read only
5 - Attempt Read of Non-Accessible Object  Skipped - Not not-accessible
6 - Attempt to Set Value > Max.256Success - did not write greater than Max
7 - Attempt to Set Value < Min.0Success - did not write less than Min
8 - Restore Object to Original Value  Failed - NoSuchName

Overall Test Case Results: Passed

Object Test Case TC-O-390
VDOT Implemented: Yes
Std Par Ref 5.12.9.3
OID1.3.6.1.4.1.1206.4.2.3.10.9.1.3.1.1
Object NamedmsGraphicBlockBitmap
Syntax Access Status
OCTET STRINGread-writeoptional
Test TypeTest ValueTest Results
1 - Read Initial Value of Object00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 ...Success
2 - Set Object to Min. Value00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 ...Success
3 - Set Object to Max. Value00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 ...Success
4 - Attempt Write to Read-Only Object 00Skipped - Not read only
5 - Attempt Read of Non-Accessible Object 00Skipped - Not not-accessible
6 - Attempt to Set Value > Max. 00Skipped - no Minimum
7 - Attempt to Set Value < Min. 00Skipped - no Minimum
8 - Restore Object to Original Value 00Failed - GenErr

Overall Test Case Results: Passed