Appendix B: Test Cases and Results (continued)
Object Test Case TC-O-151
VDOT Implemented: Yes
| Std Par Ref |
5.6.8.2 |
| OID |
1.3.6.1.4.1.1206.4.2.3.5.8.1.2.6.1 |
| Object Name |
dmsMessageNumber |
| Syntax | Access | Status |
| INTEGER (1..65535) |
read-only |
optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object |
1 |
Success |
| 2 - Set Object to Min. Value |
1 |
Success |
| 3 - Set Object to Max. Value |
1 |
Success |
| 4 - Attempt Write to Read-Only Object |
|
Failed - NoSuchName |
| 5 - Attempt Read of Non-Accessible Object |
|
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
|
Skipped - not writable |
| 7 - Attempt to Set Value < Min. |
|
Skipped - not writable |
| 8 - Restore Object to Original Value |
|
Skipped - Not writable |
Overall Test Case Results: Passed
Object Test Case TC-O-152
VDOT Implemented: Yes
| Std Par Ref |
5.6.8.2 |
| OID |
1.3.6.1.4.1.1206.4.2.3.5.8.1.2.6.2 |
| Object Name |
dmsMessageNumber |
| Syntax | Access | Status |
| INTEGER (1..65535) |
read-only |
optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object |
2 |
Success |
| 2 - Set Object to Min. Value |
2 |
Success |
| 3 - Set Object to Max. Value |
2 |
Success |
| 4 - Attempt Write to Read-Only Object |
|
Failed - NoSuchName |
| 5 - Attempt Read of Non-Accessible Object |
|
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
|
Skipped - not writable |
| 7 - Attempt to Set Value < Min. |
|
Skipped - not writable |
| 8 - Restore Object to Original Value |
|
Skipped - Not writable |
Overall Test Case Results: Passed
Object Test Case TC-O-153
VDOT Implemented: Yes
| Std Par Ref |
5.6.8.3 |
| OID |
1.3.6.1.4.1.1206.4.2.3.5.8.1.3.2.1 |
| Object Name |
dmsMessageMultiString |
| Syntax | Access | Status |
| OCTET STRING |
read-write |
optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object |
[jl3]TESTING |
Success |
| 2 - Set Object to Min. Value |
[jl3]TESTING |
Success |
| 3 - Set Object to Max. Value |
[jl3]TESTING |
Success |
| 4 - Attempt Write to Read-Only Object |
00 |
Skipped - Not read only |
| 5 - Attempt Read of Non-Accessible Object |
00 |
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
00 |
Skipped - no Minimum |
| 7 - Attempt to Set Value < Min. |
00 |
Skipped - no Minimum |
| 8 - Restore Object to Original Value |
00 |
Failed - GenErr |
Overall Test Case Results: Passed
Object Test Case TC-O-154
VDOT Implemented: Yes
| Std Par Ref |
5.6.8.3 |
| OID |
1.3.6.1.4.1.1206.4.2.3.5.8.1.3.2.2 |
| Object Name |
dmsMessageMultiString |
| Syntax | Access | Status |
| OCTET STRING |
read-write |
optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object |
[jl3]PERMANENT[nl]MESSAGE |
Success |
| 2 - Set Object to Min. Value |
[jl3]PERMANENT[nl]MESSAGE |
Success |
| 3 - Set Object to Max. Value |
[jl3]PERMANENT[nl]MESSAGE |
Success |
| 4 - Attempt Write to Read-Only Object |
00 |
Skipped - Not read only |
| 5 - Attempt Read of Non-Accessible Object | 00 |
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. | 00 |
Skipped - no Minimum |
| 7 - Attempt to Set Value < Min. | 00 |
Skipped - no Minimum |
| 8 - Restore Object to Original Value | 00 |
Failed - GenErr |
Overall Test Case Results: Passed
Object Test Case TC-O-155
VDOT Implemented: Yes
| Std Par Ref |
5.6.8.3 |
| OID |
1.3.6.1.4.1.1206.4.2.3.5.8.1.3.3.1 |
| Object Name |
dmsMessageMultiString |
| Syntax | Access | Status |
| OCTET STRING |
read-write |
optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object |
TEST MSG |
Success |
| 2 - Set Object to Min. Value |
TEST MSG |
Success |
| 3 - Set Object to Max. Value |
TEST MSG |
Success |
| 4 - Attempt Write to Read-Only Object | 00 |
Skipped - Not read only |
| 5 - Attempt Read of Non-Accessible Object | 00 |
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. | 00 |
Skipped - no Minimum |
| 7 - Attempt to Set Value < Min. | 00 |
Skipped - no Minimum |
| 8 - Restore Object to Original Value | 00 |
Failed - GenErr |
Overall Test Case Results: Passed
Object Test Case TC-O-156
VDOT Implemented: Yes
| Std Par Ref |
5.6.8.3 |
| OID |
1.3.6.1.4.1.1206.4.2.3.5.8.1.3.3.2 |
| Object Name |
dmsMessageMultiString |
| Syntax | Access | Status |
| OCTET STRING |
read-write |
optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object |
[jp3][jl3]DYNAMIC[nl2][jl2]MESSAGE[nl2][jl3]TESTING1231 |
Success |
| 2 - Set Object to Min. Value |
[jp3][jl3]DYNAMIC[nl2][jl2]MESSAGE[nl2][jl3]TESTING1231 |
Success |
| 3 - Set Object to Max. Value |
[jp3][jl3]DYNAMIC[nl2][jl2]MESSAGE[nl2][jl3]TESTING1231 |
Success |
| 4 - Attempt Write to Read-Only Object | 00 |
Skipped - Not read only |
| 5 - Attempt Read of Non-Accessible Object | 00 |
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. | 00 |
Skipped - no Minimum |
| 7 - Attempt to Set Value < Min. | 00 |
Skipped - no Minimum |
| 8 - Restore Object to Original Value | 00 |
Failed - GenErr |
Overall Test Case Results: Passed
Object Test Case TC-O-157
VDOT Implemented: Yes
| Std Par Ref |
5.6.8.3 |
| OID |
1.3.6.1.4.1.1206.4.2.3.5.8.1.3.4.1 |
| Object Name |
dmsMessageMultiString |
| Syntax | Access | Status |
| OCTET STRING |
read-write |
optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object |
VOLATILE[nl]MESSAGE |
Success |
| 2 - Set Object to Min. Value |
VOLATILE[nl]MESSAGE |
Success |
| 3 - Set Object to Max. Value |
VOLATILE[nl]MESSAGE |
Success |
| 4 - Attempt Write to Read-Only Object | 00 |
Skipped - Not read only |
| 5 - Attempt Read of Non-Accessible Object | 00 |
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. | 00 |
Skipped - no Minimum |
| 7 - Attempt to Set Value < Min. | 00 |
Skipped - no Minimum |
| 8 - Restore Object to Original Value | 00 |
Failed - GenErr |
Overall Test Case Results: Passed
Object Test Case TC-O-158
VDOT Implemented: Yes
| Std Par Ref |
5.6.8.3 |
| OID |
1.3.6.1.4.1.1206.4.2.3.5.8.1.3.4.2 |
| Object Name |
dmsMessageMultiString |
| Syntax | Access | Status |
| OCTET STRING |
read-write |
optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object |
|
Success |
| 2 - Set Object to Min. Value |
|
Success |
| 3 - Set Object to Max. Value |
|
Success |
| 4 - Attempt Write to Read-Only Object | 00 |
Skipped - Not read only |
| 5 - Attempt Read of Non-Accessible Object | 00 |
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. | 00 |
Skipped - no Minimum |
| 7 - Attempt to Set Value < Min. | 00 |
Skipped - no Minimum |
| 8 - Restore Object to Original Value | 00 |
Failed - GenErr |
Overall Test Case Results: Passed
Object Test Case TC-O-159
VDOT Implemented: Yes
| Std Par Ref |
5.6.8.3 |
| OID |
1.3.6.1.4.1.1206.4.2.3.5.8.1.3.5.1 |
| Object Name |
dmsMessageMultiString |
| Syntax | Access | Status |
| OCTET STRING |
read-write |
optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object |
|
Success |
| 2 - Set Object to Min. Value |
|
Success |
| 3 - Set Object to Max. Value |
|
Success |
| 4 - Attempt Write to Read-Only Object | 00 |
Skipped - Not read only |
| 5 - Attempt Read of Non-Accessible Object | 00 |
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. | 00 |
Skipped - no Minimum |
| 7 - Attempt to Set Value < Min. | 00 |
Skipped - no Minimum |
| 8 - Restore Object to Original Value | 00 |
Failed - GenErr |
Overall Test Case Results: Passed
Object Test Case TC-O-160
VDOT Implemented: Yes
| Std Par Ref |
5.6.8.3 |
| OID |
1.3.6.1.4.1.1206.4.2.3.5.8.1.3.5.2 |
| Object Name |
dmsMessageMultiString |
| Syntax | Access | Status |
| OCTET STRING |
read-write |
optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object |
|
Success |
| 2 - Set Object to Min. Value |
|
Success |
| 3 - Set Object to Max. Value |
|
Success |
| 4 - Attempt Write to Read-Only Object | 00 |
Skipped - Not read only |
| 5 - Attempt Read of Non-Accessible Object | 00 |
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. | 00 |
Skipped - no Minimum |
| 7 - Attempt to Set Value < Min. | 00 |
Skipped - no Minimum |
| 8 - Restore Object to Original Value | 00 |
Failed - GenErr |
Overall Test Case Results: Passed
Object Test Case TC-O-161
VDOT Implemented: Yes
| Std Par Ref |
5.6.8.3 |
| OID |
1.3.6.1.4.1.1206.4.2.3.5.8.1.3.6.1 |
| Object Name |
dmsMessageMultiString |
| Syntax | Access | Status |
| OCTET STRING |
read-write |
optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object |
|
Success |
| 2 - Set Object to Min. Value |
|
Success |
| 3 - Set Object to Max. Value |
|
Success |
| 4 - Attempt Write to Read-Only Object | 00 |
Skipped - Not read only |
| 5 - Attempt Read of Non-Accessible Object | 00 |
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. | 00 |
Skipped - no Minimum |
| 7 - Attempt to Set Value < Min. | 00 |
Skipped - no Minimum |
| 8 - Restore Object to Original Value | 00 |
Failed - GenErr |
Overall Test Case Results: Passed
Object Test Case TC-O-162
VDOT Implemented: Yes
| Std Par Ref |
5.6.8.3 |
| OID |
1.3.6.1.4.1.1206.4.2.3.5.8.1.3.6.2 |
| Object Name |
dmsMessageMultiString |
| Syntax | Access | Status |
| OCTET STRING |
read-write |
optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object |
|
Success |
| 2 - Set Object to Min. Value |
|
Success |
| 3 - Set Object to Max. Value |
|
Success |
| 4 - Attempt Write to Read-Only Object | 00 |
Skipped - Not read only |
| 5 - Attempt Read of Non-Accessible Object | 00 |
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. | 00 |
Skipped - no Minimum |
| 7 - Attempt to Set Value < Min. | 00 |
Skipped - no Minimum |
| 8 - Restore Object to Original Value | 00 |
Failed - GenErr |
Overall Test Case Results: Passed
Object Test Case TC-O-163
VDOT Implemented: Yes
| Std Par Ref |
5.6.8.4 |
| OID |
1.3.6.1.4.1.1206.4.2.3.5.8.1.4.2.1 |
| Object Name |
dmsMessageOwner |
| Syntax | Access | Status |
| OwnerString |
read-write |
optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object |
|
Success |
| 2 - Set Object to Min. Value |
|
Success |
| 3 - Set Object to Max. Value |
|
Success |
| 4 - Attempt Write to Read-Only Object | 00 |
Skipped - Not read only |
| 5 - Attempt Read of Non-Accessible Object | 00 |
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. | 00 |
Skipped - no Minimum |
| 7 - Attempt to Set Value < Min. | 00 |
Skipped - no Minimum |
| 8 - Restore Object to Original Value | 00 |
Failed - GenErr |
Overall Test Case Results: Passed
Object Test Case TC-O-164
VDOT Implemented: Yes
| Std Par Ref |
5.6.8.4 |
| OID |
1.3.6.1.4.1.1206.4.2.3.5.8.1.4.2.2 |
| Object Name |
dmsMessageOwner |
| Syntax | Access | Status |
| OwnerString |
read-write |
optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object |
|
Success |
| 2 - Set Object to Min. Value |
|
Success |
| 3 - Set Object to Max. Value |
|
Success |
| 4 - Attempt Write to Read-Only Object | 00 |
Skipped - Not read only |
| 5 - Attempt Read of Non-Accessible Object | 00 |
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
00 |
Skipped - no Minimum |
| 7 - Attempt to Set Value < Min. |
00 |
Skipped - no Minimum |
| 8 - Restore Object to Original Value | 00 |
Failed - GenErr |
Overall Test Case Results: Passed
Object Test Case TC-O-165
VDOT Implemented: Yes
| Std Par Ref |
5.6.8.4 |
| OID |
1.3.6.1.4.1.1206.4.2.3.5.8.1.4.3.1 |
| Object Name |
dmsMessageOwner |
| Syntax | Access | Status |
| OwnerString |
read-write |
optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object |
battelle |
Success |
| 2 - Set Object to Min. Value |
battelle |
Success |
| 3 - Set Object to Max. Value |
battelle |
Success |
| 4 - Attempt Write to Read-Only Object | 00 |
Skipped - Not read only |
| 5 - Attempt Read of Non-Accessible Object | 00 |
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. | 00 |
Skipped - no Minimum |
| 7 - Attempt to Set Value < Min. | 00 |
Skipped - no Minimum |
| 8 - Restore Object to Original Value | 00 |
Failed - GenErr |
Overall Test Case Results: Passed
Object Test Case TC-O-166
VDOT Implemented: Yes
| Std Par Ref |
5.6.8.4 |
| OID |
1.3.6.1.4.1.1206.4.2.3.5.8.1.4.3.2 |
| Object Name |
dmsMessageOwner |
| Syntax | Access | Status |
| OwnerString |
read-write |
optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object |
|
Success |
| 2 - Set Object to Min. Value |
|
Success |
| 3 - Set Object to Max. Value |
|
Success |
| 4 - Attempt Write to Read-Only Object | 00 |
Skipped - Not read only |
| 5 - Attempt Read of Non-Accessible Object | 00 |
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. | 00 |
Skipped - no Minimum |
| 7 - Attempt to Set Value < Min. | 00 |
Skipped - no Minimum |
| 8 - Restore Object to Original Value | 00 |
Failed - GenErr |
Overall Test Case Results: Passed
Object Test Case TC-O-167
VDOT Implemented: Yes
| Std Par Ref |
5.6.8.4 |
| OID |
1.3.6.1.4.1.1206.4.2.3.5.8.1.4.4.1 |
| Object Name |
dmsMessageOwner |
| Syntax | Access | Status |
| OwnerString |
read-write |
optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object |
ISTT |
Success |
| 2 - Set Object to Min. Value |
ISTT |
Success |
| 3 - Set Object to Max. Value |
ISTT |
Success |
| 4 - Attempt Write to Read-Only Object | 00 |
Skipped - Not read only |
| 5 - Attempt Read of Non-Accessible Object | 00 |
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. | 00 |
Skipped - no Minimum |
| 7 - Attempt to Set Value < Min. | 00 |
Skipped - no Minimum |
| 8 - Restore Object to Original Value | 00 |
Failed - GenErr |
Overall Test Case Results: Passed
Object Test Case TC-O-168
VDOT Implemented: Yes
| Std Par Ref |
5.6.8.4 |
| OID |
1.3.6.1.4.1.1206.4.2.3.5.8.1.4.4.2 |
| Object Name |
dmsMessageOwner |
| Syntax | Access | Status |
| OwnerString |
read-write |
optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object |
|
Success |
| 2 - Set Object to Min. Value |
|
Success |
| 3 - Set Object to Max. Value |
|
Success |
| 4 - Attempt Write to Read-Only Object | 00 |
Skipped - Not read only |
| 5 - Attempt Read of Non-Accessible Object | 00 |
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
00 |
Skipped - no Minimum |
| 7 - Attempt to Set Value < Min. |
00 |
Skipped - no Minimum |
| 8 - Restore Object to Original Value | 00 |
Failed - GenErr |
Overall Test Case Results: Passed
Object Test Case TC-O-169
VDOT Implemented: Yes
| Std Par Ref |
5.6.8.4 |
| OID |
1.3.6.1.4.1.1206.4.2.3.5.8.1.4.5.1 |
| Object Name |
dmsMessageOwner |
| Syntax | Access | Status |
| OwnerString |
read-write |
optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object |
|
Success |
| 2 - Set Object to Min. Value |
|
Success |
| 3 - Set Object to Max. Value |
|
Success |
| 4 - Attempt Write to Read-Only Object | 00 |
Skipped - Not read only |
| 5 - Attempt Read of Non-Accessible Object | 00 |
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
00 |
Skipped - no Minimum |
| 7 - Attempt to Set Value < Min. |
00 |
Skipped - no Minimum |
| 8 - Restore Object to Original Value | 00 |
Failed - GenErr |
Overall Test Case Results: Passed
Object Test Case TC-O-170
VDOT Implemented: Yes
| Std Par Ref |
5.6.8.4 |
| OID |
1.3.6.1.4.1.1206.4.2.3.5.8.1.4.5.2 |
| Object Name |
dmsMessageOwner |
| Syntax | Access | Status |
| OwnerString |
read-write |
optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object |
|
Success |
| 2 - Set Object to Min. Value |
|
Success |
| 3 - Set Object to Max. Value |
|
Success |
| 4 - Attempt Write to Read-Only Object | 00 |
Skipped - Not read only |
| 5 - Attempt Read of Non-Accessible Object | 00 |
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
00 |
Skipped - no Minimum |
| 7 - Attempt to Set Value < Min. |
00 |
Skipped - no Minimum |
| 8 - Restore Object to Original Value | 00 |
Failed - GenErr |
Overall Test Case Results: Passed
Object Test Case TC-O-171
VDOT Implemented: Yes
| Std Par Ref |
5.6.8.4 |
| OID |
1.3.6.1.4.1.1206.4.2.3.5.8.1.4.6.1 |
| Object Name |
dmsMessageOwner |
| Syntax | Access | Status |
| OwnerString |
read-write |
optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object |
|
Success |
| 2 - Set Object to Min. Value |
|
Success |
| 3 - Set Object to Max. Value |
|
Success |
| 4 - Attempt Write to Read-Only Object | 00 |
Skipped - Not read only |
| 5 - Attempt Read of Non-Accessible Object | 00 |
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. | 00 |
Skipped - no Minimum |
| 7 - Attempt to Set Value < Min. | 00 |
Skipped - no Minimum |
| 8 - Restore Object to Original Value | 00 |
Failed - GenErr |
Overall Test Case Results: Passed
Object Test Case TC-O-172
VDOT Implemented: Yes
| Std Par Ref |
5.6.8.4 |
| OID |
1.3.6.1.4.1.1206.4.2.3.5.8.1.4.6.2 |
| Object Name |
dmsMessageOwner |
| Syntax | Access | Status |
| OwnerString |
read-write |
optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object |
|
Success |
| 2 - Set Object to Min. Value |
|
Success |
| 3 - Set Object to Max. Value |
|
Success |
| 4 - Attempt Write to Read-Only Object | 00 |
Skipped - Not read only |
| 5 - Attempt Read of Non-Accessible Object | 00 |
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. | 00 |
Skipped - no Minimum |
| 7 - Attempt to Set Value < Min. | 00 |
Skipped - no Minimum |
| 8 - Restore Object to Original Value | 00 |
Failed - GenErr |
Overall Test Case Results: Passed
Object Test Case TC-O-173
VDOT Implemented: Yes
| Std Par Ref |
5.6.8.5 |
| OID |
1.3.6.1.4.1.1206.4.2.3.5.8.1.5.2.1 |
| Object Name |
dmsMessageCRC |
| Syntax | Access | Status |
| INTEGER (0..65535) |
read-only |
optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object |
61236 |
Success |
| 2 - Set Object to Min. Value |
61236 |
Success |
| 3 - Set Object to Max. Value |
0 |
Success |
| 4 - Attempt Write to Read-Only Object |
|
Failed - NoSuchName |
| 5 - Attempt Read of Non-Accessible Object |
|
Skipped - Not not-accessible |
| 7 - Attempt to Set Value < Min.. |
|
Skipped - not writable |
| 6 - Attempt to Set Value > Max |
|
Skipped - not writable |
| 8 - Restore Object to Original Value |
|
Skipped - Not writable |
Overall Test Case Results: Passed
Object Test Case TC-O-174
VDOT Implemented: Yes
| Std Par Ref |
5.6.8.5 |
| OID |
1.3.6.1.4.1.1206.4.2.3.5.8.1.5.2.2 |
| Object Name |
dmsMessageCRC |
| Syntax | Access | Status |
| INTEGER (0..65535) |
read-only |
optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object |
4346 |
Success |
| 2 - Set Object to Min. Value |
4346 |
Success |
| 3 - Set Object to Max. Value |
0 |
Success |
| 4 - Attempt Write to Read-Only Object |
|
Failed - NoSuchName |
| 5 - Attempt Read of Non-Accessible Object |
|
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
|
Skipped - not writable |
| 7 - Attempt to Set Value < Min. |
|
Skipped - not writable |
| 8 - Restore Object to Original Value |
|
Skipped - Not writable |
Overall Test Case Results: Passed
Object Test Case TC-O-175
VDOT Implemented: Yes
| Std Par Ref |
5.6.8.5 |
| OID |
1.3.6.1.4.1.1206.4.2.3.5.8.1.5.3.1 |
| Object Name |
dmsMessageCRC |
| Syntax | Access | Status |
| INTEGER (0..65535) |
read-only |
optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object |
51247 |
Success |
| 2 - Set Object to Min. Value |
51247 |
Success |
| 3 - Set Object to Max. Value |
51247 |
Success |
| 4 - Attempt Write to Read-Only Object |
|
Failed - NoSuchName |
| 5 - Attempt Read of Non-Accessible Object |
|
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
|
Skipped - not writable |
| 7 - Attempt to Set Value < Min. |
|
Skipped - not writable |
| 8 - Restore Object to Original Value |
|
Skipped - Not writable |
Overall Test Case Results: Passed
Object Test Case TC-O-176
VDOT Implemented: Yes
| Std Par Ref |
5.6.8.5 |
| OID |
1.3.6.1.4.1.1206.4.2.3.5.8.1.5.3.2 |
| Object Name |
dmsMessageCRC |
| Syntax | Access | Status |
| INTEGER (0..65535) |
read-only |
optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object |
27735 |
Success |
| 2 - Set Object to Min. Value |
27735 |
Success |
| 3 - Set Object to Max. Value |
27735 |
Success |
| 4 - Attempt Write to Read-Only Object |
|
Failed - NoSuchName |
| 5 - Attempt Read of Non-Accessible Object |
|
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
|
Skipped - not writable |
| 7 - Attempt to Set Value < Min. |
|
Skipped - not writable |
| 8 - Restore Object to Original Value |
|
Skipped - Not writable |
Overall Test Case Results: Passed
Object Test Case TC-O-177
VDOT Implemented: Yes
| Std Par Ref |
5.6.8.5 |
| OID |
1.3.6.1.4.1.1206.4.2.3.5.8.1.5.4.1 |
| Object Name |
dmsMessageCRC |
| Syntax | Access | Status |
| INTEGER (0..65535) |
read-only |
optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object |
19307 |
Success |
| 2 - Set Object to Min. Value |
19307 |
Success |
| 3 - Set Object to Max. Value |
19307 |
Success |
| 4 - Attempt Write to Read-Only Object |
|
Failed - NoSuchName |
| 5 - Attempt Read of Non-Accessible Object |
|
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
|
Skipped - not writable |
| 7 - Attempt to Set Value < Min. |
|
Skipped - not writable |
| 8 - Restore Object to Original Value |
|
Skipped - Not writable |
Overall Test Case Results: Passed
Object Test Case TC-O-178
VDOT Implemented: Yes
| Std Par Ref |
5.6.8.5 |
| OID |
1.3.6.1.4.1.1206.4.2.3.5.8.1.5.4.2 |
| Object Name |
dmsMessageCRC |
| Syntax | Access | Status |
| INTEGER (0..65535) |
read-only |
optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object |
0 |
Success |
| 2 - Set Object to Min. Value |
0 |
Success |
| 3 - Set Object to Max. Value |
0 |
Success |
| 4 - Attempt Write to Read-Only Object |
|
Failed - NoSuchName |
| 5 - Attempt Read of Non-Accessible Object |
|
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
|
Skipped - not writable |
| 7 - Attempt to Set Value < Min. |
|
Skipped - not writable |
| 8 - Restore Object to Original Value |
|
Skipped - Not writable |
Overall Test Case Results: Passed
Object Test Case TC-O-179
VDOT Implemented: Yes
| Std Par Ref |
5.6.8.5 |
| OID |
1.3.6.1.4.1.1206.4.2.3.5.8.1.5.5.1 |
| Object Name |
dmsMessageCRC |
| Syntax | Access | Status |
| INTEGER (0..65535) |
read-only |
optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object |
0 |
Success |
| 2 - Set Object to Min. Value |
0 |
Success |
| 3 - Set Object to Max. Value |
0 |
Success |
| 4 - Attempt Write to Read-Only Object |
|
Failed - NoSuchName |
| 5 - Attempt Read of Non-Accessible Object |
|
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
|
Skipped - not writable |
| 7 - Attempt to Set Value < Min. |
|
Skipped - not writable |
| 8 - Restore Object to Original Value |
|
Skipped - Not writable |
Overall Test Case Results: Passed
Object Test Case TC-O-180
VDOT Implemented: Yes
| Std Par Ref |
5.6.8.5 |
| OID |
1.3.6.1.4.1.1206.4.2.3.5.8.1.5.5.2 |
| Object Name |
dmsMessageCRC |
| Syntax | Access | Status |
| INTEGER (0..65535) |
read-only |
optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object |
0 |
Success |
| 2 - Set Object to Min. Value |
0 |
Success |
| 3 - Set Object to Max. Value |
0 |
Success |
| 4 - Attempt Write to Read-Only Object |
|
Failed - NoSuchName |
| 5 - Attempt Read of Non-Accessible Object |
|
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
|
Skipped - not writable |
| 7 - Attempt to Set Value < Min. |
|
Skipped - not writable |
| 8 - Restore Object to Original Value |
|
Skipped - Not writable |
Overall Test Case Results: Passed
Object Test Case TC-O-181
VDOT Implemented: Yes
| Std Par Ref |
5.6.8.5 |
| OID |
1.3.6.1.4.1.1206.4.2.3.5.8.1.5.6.1 |
| Object Name |
dmsMessageCRC |
| Syntax | Access | Status |
| INTEGER (0..65535) |
read-only |
optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object |
18191 |
Success |
| 2 - Set Object to Min. Value |
18191 |
Success |
| 3 - Set Object to Max. Value |
18191 |
Success |
| 4 - Attempt Write to Read-Only Object |
|
Failed - NoSuchName |
| 5 - Attempt Read of Non-Accessible Object |
|
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
|
Skipped - not writable |
| 7 - Attempt to Set Value < Min. |
|
Skipped - not writable |
| 8 - Restore Object to Original Value |
|
Skipped - Not writable |
Overall Test Case Results: Passed
Object Test Case TC-O-182
VDOT Implemented: Yes
| Std Par Ref |
5.6.8.5 |
| OID |
1.3.6.1.4.1.1206.4.2.3.5.8.1.5.6.2 |
| Object Name |
dmsMessageCRC |
| Syntax | Access | Status |
| INTEGER (0..65535) |
read-only |
optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object |
0 |
Success |
| 2 - Set Object to Min. Value |
0 |
Success |
| 3 - Set Object to Max. Value |
0 |
Success |
| 4 - Attempt Write to Read-Only Object |
|
Failed - NoSuchName |
| 5 - Attempt Read of Non-Accessible Object |
|
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
|
Skipped - not writable |
| 7 - Attempt to Set Value < Min. |
|
Skipped - not writable |
| 8 - Restore Object to Original Value |
|
Skipped - Not writable |
Overall Test Case Results: Passed
Object Test Case TC-O-183
VDOT Implemented: Yes
| Std Par Ref |
5.6.8.6 |
| OID |
1.3.6.1.4.1.1206.4.2.3.5.8.1.6.2.1 |
| Object Name |
dmsMessageBeacon |
| Syntax | Access | Status |
| INTEGER (0..1) |
read-write |
optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object |
0 |
Success |
| 2 - Set Object to Min. Value |
0 |
Success |
| 3 - Set Object to Max. Value |
0 |
Success |
| 4 - Attempt Write to Read-Only Object |
|
Skipped - Not read only |
| 5 - Attempt Read of Non-Accessible Object |
|
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
2 |
Success - did not write greater than Max |
| 7 - Attempt to Set Value < Min. |
-1 |
Success - did not write less than Min |
| 8 - Restore Object to Original Value |
|
Failed - GenErr |
Overall Test Case Results: Passed
Object Test Case TC-O-184
VDOT Implemented: Yes
| Std Par Ref |
5.6.8.6 |
| OID |
1.3.6.1.4.1.1206.4.2.3.5.8.1.6.2.2 |
| Object Name |
dmsMessageBeacon |
| Syntax | Access | Status |
| INTEGER (0..1) |
read-write |
optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object |
0 |
Success |
| 2 - Set Object to Min. Value |
0 |
Success |
| 3 - Set Object to Max. Value |
0 |
Success |
| 4 - Attempt Write to Read-Only Object |
|
Skipped - Not read only |
| 5 - Attempt Read of Non-Accessible Object |
|
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
2 |
Success - did not write greater than Max |
| 7 - Attempt to Set Value < Min. |
-1 |
Success - did not write less than Min |
| 8 - Restore Object to Original Value |
|
Failed - GenErr |
Overall Test Case Results: Passed
Object Test Case TC-O-185
VDOT Implemented: Yes
| Std Par Ref |
5.6.8.6 |
| OID |
1.3.6.1.4.1.1206.4.2.3.5.8.1.6.3.1 |
| Object Name |
dmsMessageBeacon |
| Syntax | Access | Status |
| INTEGER (0..1) |
read-write |
optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object |
0 |
Success |
| 2 - Set Object to Min. Value |
0 |
Success |
| 3 - Set Object to Max. Value |
0 |
Success |
| 4 - Attempt Write to Read-Only Object |
|
Skipped - Not read only |
| 5 - Attempt Read of Non-Accessible Object |
|
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
2 |
Success - did not write greater than Max |
| 7 - Attempt to Set Value < Min. |
-1 |
Success - did not write less than Min |
| 8 - Restore Object to Original Value |
|
Failed - GenErr |
Overall Test Case Results: Passed
Object Test Case TC-O-186
VDOT Implemented: Yes
| Std Par Ref |
5.6.8.6 |
| OID |
1.3.6.1.4.1.1206.4.2.3.5.8.1.6.3.2 |
| Object Name |
dmsMessageBeacon |
| Syntax | Access | Status |
| INTEGER (0..1) |
read-write |
optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object |
0 |
Success |
| 2 - Set Object to Min. Value |
0 |
Success |
| 3 - Set Object to Max. Value |
0 |
Success |
| 4 - Attempt Write to Read-Only Object |
|
Skipped - Not read only |
| 5 - Attempt Read of Non-Accessible Object |
|
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
2 |
Success - did not write greater than Max |
| 7 - Attempt to Set Value < Min. |
-1 |
Success - did not write less than Min |
| 8 - Restore Object to Original Value |
|
Failed - GenErr |
Overall Test Case Results: Passed
Object Test Case TC-O-187
VDOT Implemented: Yes
| Std Par Ref |
5.6.8.6 |
| OID |
1.3.6.1.4.1.1206.4.2.3.5.8.1.6.4.1 |
| Object Name |
dmsMessageBeacon |
| Syntax | Access | Status |
| INTEGER (0..1) |
read-write |
optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object |
0 |
Success |
| 2 - Set Object to Min. Value |
0 |
Success |
| 3 - Set Object to Max. Value |
0 |
Success |
| 4 - Attempt Write to Read-Only Object |
|
Skipped - Not read only |
| 5 - Attempt Read of Non-Accessible Object |
|
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
2 |
Success - did not write greater than Max |
| 7 - Attempt to Set Value < Min. |
-1 |
Success - did not write less than Min |
| 8 - Restore Object to Original Value |
|
Failed - GenErr |
Overall Test Case Results: Passed
Object Test Case TC-O-188
VDOT Implemented: Yes
| Std Par Ref |
5.6.8.6 |
| OID |
1.3.6.1.4.1.1206.4.2.3.5.8.1.6.4.2 |
| Object Name |
dmsMessageBeacon |
| Syntax | Access | Status |
| INTEGER (0..1) |
read-write |
optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object |
0 |
Success |
| 2 - Set Object to Min. Value |
0 |
Success |
| 3 - Set Object to Max. Value |
0 |
Success |
| 4 - Attempt Write to Read-Only Object |
|
Skipped - Not read only |
| 5 - Attempt Read of Non-Accessible Object |
|
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
2 |
Success - did not write greater than Max |
| 7 - Attempt to Set Value < Min. |
-1 |
Success - did not write less than Min |
| 8 - Restore Object to Original Value |
|
Failed - GenErr |
Overall Test Case Results: Passed
Object Test Case TC-O-189
VDOT Implemented: Yes
| Std Par Ref |
5.6.8.6 |
| OID |
1.3.6.1.4.1.1206.4.2.3.5.8.1.6.5.1 |
| Object Name |
dmsMessageBeacon |
| Syntax | Access | Status |
| INTEGER (0..1) |
read-write |
optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object |
0 |
Success |
| 2 - Set Object to Min. Value |
0 |
Success |
| 3 - Set Object to Max. Value |
0 |
Success |
| 4 - Attempt Write to Read-Only Object |
|
Skipped - Not read only |
| 5 - Attempt Read of Non-Accessible Object |
|
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
2 |
Success - did not write greater than Max |
| 7 - Attempt to Set Value < Min. |
-1 |
Success - did not write less than Min |
| 8 - Restore Object to Original Value |
|
Failed - GenErr |
Overall Test Case Results: Passed
Object Test Case TC-O-190
VDOT Implemented: Yes
| Std Par Ref |
5.6.8.6 |
| OID |
1.3.6.1.4.1.1206.4.2.3.5.8.1.6.5.2 |
| Object Name |
dmsMessageBeacon |
| Syntax | Access | Status |
| INTEGER (0..1) |
read-write |
optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object |
0 |
Success |
| 2 - Set Object to Min. Value |
0 |
Success |
| 3 - Set Object to Max. Value |
0 |
Success |
| 4 - Attempt Write to Read-Only Object |
|
Skipped - Not read only |
| 5 - Attempt Read of Non-Accessible Object |
|
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
2 |
Success - did not write greater than Max |
| 7 - Attempt to Set Value < Min. |
-1 |
Success - did not write less than Min |
| 8 - Restore Object to Original Value |
|
Failed - GenErr |
Overall Test Case Results: Passed
Object Test Case TC-O-191
VDOT Implemented: Yes
| Std Par Ref |
5.6.8.6 |
| OID |
1.3.6.1.4.1.1206.4.2.3.5.8.1.6.6.1 |
| Object Name |
dmsMessageBeacon |
| Syntax | Access | Status |
| INTEGER (0..1) |
read-write |
optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object |
0 |
Success |
| 2 - Set Object to Min. Value |
0 |
Success |
| 3 - Set Object to Max. Value |
0 |
Success |
| 4 - Attempt Write to Read-Only Object |
|
Skipped - Not read only |
| 5 - Attempt Read of Non-Accessible Object |
|
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
2 |
Success - did not write greater than Max |
| 7 - Attempt to Set Value < Min. |
-1 |
Success - did not write less than Min |
| 8 - Restore Object to Original Value |
|
Failed - GenErr |
Overall Test Case Results: Passed
Object Test Case TC-O-192
VDOT Implemented: Yes
| Std Par Ref |
5.6.8.6 |
| OID |
1.3.6.1.4.1.1206.4.2.3.5.8.1.6.6.2 |
| Object Name |
dmsMessageBeacon |
| Syntax | Access | Status |
| INTEGER (0..1) |
read-write |
optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object |
0 |
Success |
| 2 - Set Object to Min. Value |
0 |
Success |
| 3 - Set Object to Max. Value |
0 |
Success |
| 4 - Attempt Write to Read-Only Object |
|
Skipped - Not read only |
| 5 - Attempt Read of Non-Accessible Object |
|
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
2 |
Success - did not write greater than Max |
| 7 - Attempt to Set Value < Min. |
-1 |
Success - did not write less than Min |
| 8 - Restore Object to Original Value |
|
Failed - GenErr |
Overall Test Case Results: Passed
Object Test Case TC-O-193
VDOT Implemented: Yes
| Std Par Ref |
5.6.8.7 |
| OID |
1.3.6.1.4.1.1206.4.2.3.5.8.1.7.2.1 |
| Object Name |
dmsMessagePixelService |
| Syntax | Access | Status |
| INTEGER (0..1) |
read-write |
optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object |
0 |
Success |
| 2 - Set Object to Min. Value |
0 |
Success |
| 3 - Set Object to Max. Value |
0 |
Success |
| 4 - Attempt Write to Read-Only Object |
|
Skipped - Not read only |
| 5 - Attempt Read of Non-Accessible Object |
|
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
2 |
Success - did not write greater than Max |
| 7 - Attempt to Set Value < Min. |
-1 |
Success - did not write less than Min |
| 8 - Restore Object to Original Value |
|
Failed - GenErr |
Overall Test Case Results: Passed
Object Test Case TC-O-194
VDOT Implemented: Yes
| Std Par Ref |
5.6.8.7 |
| OID |
1.3.6.1.4.1.1206.4.2.3.5.8.1.7.2.2 |
| Object Name |
dmsMessagePixelService |
| Syntax | Access | Status |
| INTEGER (0..1) |
read-write |
optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object |
0 |
Success |
| 2 - Set Object to Min. Value |
0 |
Success |
| 3 - Set Object to Max. Value |
0 |
Success |
| 4 - Attempt Write to Read-Only Object |
|
Skipped - Not read only |
| 5 - Attempt Read of Non-Accessible Object |
|
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
2 |
Success - did not write greater than Max |
| 7 - Attempt to Set Value < Min. |
-1 |
Success - did not write less than Min |
| 8 - Restore Object to Original Value |
|
Failed - GenErr |
Overall Test Case Results: Passed
Object Test Case TC-O-195
VDOT Implemented: Yes
| Std Par Ref |
5.6.8.7 |
| OID |
1.3.6.1.4.1.1206.4.2.3.5.8.1.7.3.1 |
| Object Name |
dmsMessagePixelService |
| Syntax | Access | Status |
| INTEGER (0..1) |
read-write |
optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object |
0 |
Success |
| 2 - Set Object to Min. Value |
0 |
Success |
| 3 - Set Object to Max. Value |
0 |
Success |
| 4 - Attempt Write to Read-Only Object |
|
Skipped - Not read only |
| 5 - Attempt Read of Non-Accessible Object |
|
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
2 |
Success - did not write greater than Max |
| 7 - Attempt to Set Value < Min. |
-1 |
Success - did not write less than Min |
| 8 - Restore Object to Original Value |
|
Failed - GenErr |
Overall Test Case Results: Passed
Object Test Case TC-O-196
VDOT Implemented: Yes
| Std Par Ref |
5.6.8.7 |
| OID |
1.3.6.1.4.1.1206.4.2.3.5.8.1.7.3.2 |
| Object Name |
dmsMessagePixelService |
| Syntax | Access | Status |
| INTEGER (0..1) |
read-write |
optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object |
0 |
Success |
| 2 - Set Object to Min. Value |
0 |
Success |
| 3 - Set Object to Max. Value |
0 |
Success |
| 4 - Attempt Write to Read-Only Object |
|
Skipped - Not read only |
| 5 - Attempt Read of Non-Accessible Object |
|
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
2 |
Success - did not write greater than Max |
| 7 - Attempt to Set Value < Min. |
-1 |
Success - did not write less than Min |
| 8 - Restore Object to Original Value |
|
Failed - GenErr |
Overall Test Case Results: Passed
Object Test Case TC-O-197
VDOT Implemented: Yes
| Std Par Ref |
5.6.8.7 |
| OID |
1.3.6.1.4.1.1206.4.2.3.5.8.1.7.4.1 |
| Object Name |
dmsMessagePixelService |
| Syntax | Access | Status |
| INTEGER (0..1) |
read-write |
optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object |
0 |
Success |
| 2 - Set Object to Min. Value |
0 |
Success |
| 3 - Set Object to Max. Value |
0 |
Success |
| 4 - Attempt Write to Read-Only Object |
|
Skipped - Not read only |
| 5 - Attempt Read of Non-Accessible Object |
|
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
2 |
Success - did not write greater than Max |
| 7 - Attempt to Set Value < Min. |
-1 |
Success - did not write less than Min |
| 8 - Restore Object to Original Value |
|
Failed - GenErr |
Overall Test Case Results: Passed
Object Test Case TC-O-198
VDOT Implemented: Yes
| Std Par Ref |
5.6.8.7 |
| OID |
1.3.6.1.4.1.1206.4.2.3.5.8.1.7.4.2 |
| Object Name |
dmsMessagePixelService |
| Syntax | Access | Status |
| INTEGER (0..1) |
read-write |
optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object |
0 |
Success |
| 2 - Set Object to Min. Value |
0 |
Success |
| 3 - Set Object to Max. Value |
0 |
Success |
| 4 - Attempt Write to Read-Only Object |
|
Skipped - Not read only |
| 5 - Attempt Read of Non-Accessible Object |
|
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
2 |
Success - did not write greater than Max |
| 7 - Attempt to Set Value < Min. |
-1 |
Success - did not write less than Min |
| 8 - Restore Object to Original Value |
|
Failed - GenErr |
Overall Test Case Results: Passed
Object Test Case TC-O-199
VDOT Implemented: Yes
| Std Par Ref |
5.6.8.7 |
| OID |
1.3.6.1.4.1.1206.4.2.3.5.8.1.7.5.1 |
| Object Name |
dmsMessagePixelService |
| Syntax | Access | Status |
| INTEGER (0..1) |
read-write |
optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object |
0 |
Success |
| 2 - Set Object to Min. Value |
0 |
Success |
| 3 - Set Object to Max. Value |
0 |
Success |
| 4 - Attempt Write to Read-Only Object |
|
Skipped - Not read only |
| 5 - Attempt Read of Non-Accessible Object |
|
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
2 |
Success - did not write greater than Max |
| 7 - Attempt to Set Value < Min. |
-1 |
Success - did not write less than Min |
| 8 - Restore Object to Original Value |
|
Failed - GenErr |
Overall Test Case Results: Passed
Object Test Case TC-O-200
VDOT Implemented: Yes
| Std Par Ref |
5.6.8.7 |
| OID |
1.3.6.1.4.1.1206.4.2.3.5.8.1.7.5.2 |
| Object Name |
dmsMessagePixelService |
| Syntax | Access | Status |
| INTEGER (0..1) |
read-write |
optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object |
0 |
Success |
| 2 - Set Object to Min. Value |
0 |
Success |
| 3 - Set Object to Max. Value |
0 |
Success |
| 4 - Attempt Write to Read-Only Object |
|
Skipped - Not read only |
| 5 - Attempt Read of Non-Accessible Object |
|
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
2 |
Success - did not write greater than Max |
| 7 - Attempt to Set Value < Min. |
-1 |
Success - did not write less than Min |
| 8 - Restore Object to Original Value |
|
Failed - GenErr |
Overall Test Case Results: Passed
Object Test Case TC-O-201
VDOT Implemented: Yes
| Std Par Ref |
5.6.8.7 |
| OID |
1.3.6.1.4.1.1206.4.2.3.5.8.1.7.6.1 |
| Object Name |
dmsMessagePixelService |
| Syntax | Access | Status |
| INTEGER (0..1) |
read-write |
optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object |
0 |
Success |
| 2 - Set Object to Min. Value |
0 |
Success |
| 3 - Set Object to Max. Value |
0 |
Success |
| 4 - Attempt Write to Read-Only Object |
|
Skipped - Not read only |
| 5 - Attempt Read of Non-Accessible Object |
|
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
2 |
Success - did not write greater than Max |
| 7 - Attempt to Set Value < Min. |
-1 |
Success - did not write less than Min |
| 8 - Restore Object to Original Value |
|
Failed - GenErr |
Overall Test Case Results: Passed
Object Test Case TC-O-202
VDOT Implemented: Yes
| Std Par Ref |
5.6.8.7 |
| OID |
1.3.6.1.4.1.1206.4.2.3.5.8.1.7.6.2 |
| Object Name |
dmsMessagePixelService |
| Syntax | Access | Status |
| INTEGER (0..1) |
read-write |
optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object |
0 |
Success |
| 2 - Set Object to Min. Value |
0 |
Success |
| 3 - Set Object to Max. Value |
0 |
Success |
| 4 - Attempt Write to Read-Only Object |
|
Skipped - Not read only |
| 5 - Attempt Read of Non-Accessible Object |
|
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
2 |
Success - did not write greater than Max |
| 7 - Attempt to Set Value < Min. |
-1 |
Success - did not write less than Min |
| 8 - Restore Object to Original Value |
|
Failed - GenErr |
Overall Test Case Results: Passed
Object Test Case TC-O-203
VDOT Implemented: Yes
| Std Par Ref |
5.6.8.8 |
| OID |
1.3.6.1.4.1.1206.4.2.3.5.8.1.8.2.1 |
| Object Name |
dmsMessageRunTimePriority |
| Syntax | Access | Status |
| INTEGER (1..255) |
read-write |
optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object |
1 |
Success |
| 2 - Set Object to Min. Value |
1 |
Success |
| 3 - Set Object to Max. Value |
1 |
Success |
| 4 - Attempt Write to Read-Only Object |
|
Skipped - Not read only |
| 5 - Attempt Read of Non-Accessible Object |
|
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
256 |
Success - did not write greater than Max |
| 7 - Attempt to Set Value < Min. |
0 |
Success - did not write less than Min |
| 8 - Restore Object to Original Value |
|
Failed - GenErr |
Overall Test Case Results: Passed
Object Test Case TC-O-204
VDOT Implemented: Yes
| Std Par Ref |
5.6.8.8 |
| OID |
1.3.6.1.4.1.1206.4.2.3.5.8.1.8.2.2 |
| Object Name |
dmsMessageRunTimePriority |
| Syntax | Access | Status |
| INTEGER (1..255) |
read-write |
optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object |
1 |
Success |
| 2 - Set Object to Min. Value |
1 |
Success |
| 3 - Set Object to Max. Value |
1 |
Success |
| 4 - Attempt Write to Read-Only Object |
|
Skipped - Not read only |
| 5 - Attempt Read of Non-Accessible Object |
|
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
256 |
Success - did not write greater than Max |
| 7 - Attempt to Set Value < Min. |
0 |
Success - did not write less than Min |
| 8 - Restore Object to Original Value |
|
Failed - GenErr |
Overall Test Case Results: Passed
Object Test Case TC-O-205
VDOT Implemented: Yes
| Std Par Ref |
5.6.8.8 |
| OID |
1.3.6.1.4.1.1206.4.2.3.5.8.1.8.3.1 |
| Object Name |
dmsMessageRunTimePriority |
| Syntax | Access | Status |
| INTEGER (1..255) |
read-write |
optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object |
1 |
Success |
| 2 - Set Object to Min. Value |
1 |
Success |
| 3 - Set Object to Max. Value |
1 |
Success |
| 4 - Attempt Write to Read-Only Object |
|
Skipped - Not read only |
| 5 - Attempt Read of Non-Accessible Object |
|
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
256 |
Success - did not write greater than Max |
| 7 - Attempt to Set Value < Min. |
0 |
Success - did not write less than Min |
| 8 - Restore Object to Original Value |
|
Failed - GenErr |
Overall Test Case Results: Passed
Object Test Case TC-O-206
VDOT Implemented: Yes
| Std Par Ref |
5.6.8.8 |
| OID |
1.3.6.1.4.1.1206.4.2.3.5.8.1.8.3.2 |
| Object Name |
dmsMessageRunTimePriority |
| Syntax | Access | Status |
| INTEGER (1..255) |
read-write |
optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object |
1 |
Success |
| 2 - Set Object to Min. Value |
1 |
Success |
| 3 - Set Object to Max. Value |
1 |
Success |
| 4 - Attempt Write to Read-Only Object |
|
Skipped - Not read only |
| 5 - Attempt Read of Non-Accessible Object |
|
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
256 |
Success - did not write greater than Max |
| 7 - Attempt to Set Value < Min. |
0 |
Success - did not write less than Min |
| 8 - Restore Object to Original Value |
|
Failed - GenErr |
Overall Test Case Results: Passed
Object Test Case TC-O-207
VDOT Implemented: Yes
| Std Par Ref |
5.6.8.8 |
| OID |
1.3.6.1.4.1.1206.4.2.3.5.8.1.8.4.1 |
| Object Name |
dmsMessageRunTimePriority |
| Syntax | Access | Status |
| INTEGER (1..255) |
read-write |
optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object |
14 |
Success |
| 2 - Set Object to Min. Value |
14 |
Success |
| 3 - Set Object to Max. Value |
14 |
Success |
| 4 - Attempt Write to Read-Only Object |
|
Skipped - Not read only |
| 5 - Attempt Read of Non-Accessible Object |
|
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
256 |
Success - did not write greater than Max |
| 7 - Attempt to Set Value < Min. |
0 |
Success - did not write less than Min |
| 8 - Restore Object to Original Value |
|
Failed - GenErr |
Overall Test Case Results: Passed
Object Test Case TC-O-208
VDOT Implemented: Yes
| Std Par Ref |
5.6.8.8 |
| OID |
1.3.6.1.4.1.1206.4.2.3.5.8.1.8.4.2 |
| Object Name |
dmsMessageRunTimePriority |
| Syntax | Access | Status |
| INTEGER (1..255) |
read-write |
optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object |
1 |
Success |
| 2 - Set Object to Min. Value |
1 |
Success |
| 3 - Set Object to Max. Value |
1 |
Success |
| 4 - Attempt Write to Read-Only Object |
|
Skipped - Not read only |
| 5 - Attempt Read of Non-Accessible Object |
|
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
256 |
Success - did not write greater than Max |
| 7 - Attempt to Set Value < Min. |
0 |
Success - did not write less than Min |
| 8 - Restore Object to Original Value |
|
Failed - GenErr |
Overall Test Case Results: Passed
Object Test Case TC-O-209
VDOT Implemented: Yes
| Std Par Ref |
5.6.8.8 |
| OID |
1.3.6.1.4.1.1206.4.2.3.5.8.1.8.5.1 |
| Object Name |
dmsMessageRunTimePriority |
| Syntax | Access | Status |
| INTEGER (1..255) |
read-write |
optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object |
1 |
Success |
| 2 - Set Object to Min. Value |
1 |
Success |
| 3 - Set Object to Max. Value |
1 |
Success |
| 4 - Attempt Write to Read-Only Object |
|
Skipped - Not read only |
| 5 - Attempt Read of Non-Accessible Object |
|
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
256 |
Success - did not write greater than Max |
| 7 - Attempt to Set Value < Min. |
0 |
Success - did not write less than Min |
| 8 - Restore Object to Original Value |
|
Failed - GenErr |
Overall Test Case Results: Passed
Object Test Case TC-O-210
VDOT Implemented: Yes
| Std Par Ref |
5.6.8.8 |
| OID |
1.3.6.1.4.1.1206.4.2.3.5.8.1.8.5.2 |
| Object Name |
dmsMessageRunTimePriority |
| Syntax | Access | Status |
| INTEGER (1..255) |
read-write |
optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object |
1 |
Success |
| 2 - Set Object to Min. Value |
1 |
Success |
| 3 - Set Object to Max. Value |
1 |
Success |
| 4 - Attempt Write to Read-Only Object |
|
Skipped - Not read only |
| 5 - Attempt Read of Non-Accessible Object |
|
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
256 |
Success - did not write greater than Max |
| 7 - Attempt to Set Value < Min. |
0 |
Success - did not write less than Min |
| 8 - Restore Object to Original Value |
|
Failed - GenErr |
Overall Test Case Results: Passed
Object Test Case TC-O-211
VDOT Implemented: Yes
| Std Par Ref |
5.6.8.8 |
| OID |
1.3.6.1.4.1.1206.4.2.3.5.8.1.8.6.1 |
| Object Name |
dmsMessageRunTimePriority |
| Syntax | Access | Status |
| INTEGER (1..255) |
read-write |
optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object |
1 |
Success |
| 2 - Set Object to Min. Value |
1 |
Success |
| 3 - Set Object to Max. Value |
255 |
Success |
| 4 - Attempt Write to Read-Only Object |
|
Skipped - Not read only |
| 5 - Attempt Read of Non-Accessible Object |
|
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
256 |
Success - did not write greater than Max |
| 7 - Attempt to Set Value < Min. |
0 |
Success - did not write less than Min |
| 8 - Restore Object to Original Value |
1 |
Success |
Overall Test Case Results: Passed
Object Test Case TC-O-212
VDOT Implemented: Yes
| Std Par Ref |
5.6.8.8 |
| OID |
1.3.6.1.4.1.1206.4.2.3.5.8.1.8.6.2 |
| Object Name |
dmsMessageRunTimePriority |
| Syntax | Access | Status |
| INTEGER (1..255) |
read-write |
optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object |
1 |
Success |
| 2 - Set Object to Min. Value |
1 |
Success |
| 3 - Set Object to Max. Value |
1 |
Success |
| 4 - Attempt Write to Read-Only Object |
|
Skipped - Not read only |
| 5 - Attempt Read of Non-Accessible Object |
|
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
256 |
Success - did not write greater than Max |
| 7 - Attempt to Set Value < Min. |
0 |
Success - did not write less than Min |
| 8 - Restore Object to Original Value |
|
Failed - GenErr |
Overall Test Case Results: Passed
Object Test Case TC-O-213
VDOT Implemented: Yes
| Std Par Ref |
5.6.8.9 |
| OID |
1.3.6.1.4.1.1206.4.2.3.5.8.1.9.2.1 |
| Object Name |
dmsMessageStatus |
| Syntax | Access | Status |
| INTEGER {enumeration} |
read-write |
optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object |
4 (valid) |
Success |
| 2 - Set Object to Min. Value |
4 (valid) |
Success |
| 3 - Set Object to Max. Value |
5 (error) |
Success |
| 4 - Attempt Write to Read-Only Object |
|
Skipped - Not read only |
| 5 - Attempt Read of Non-Accessible Object |
|
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
|
Skipped - no Minimum |
| 7 - Attempt to Set Value < Min. |
|
Skipped - no Minimum |
| 8 - Restore Object to Original Value |
|
Failed - GenErr |
Overall Test Case Results: Passed
Object Test Case TC-O-214
VDOT Implemented: Yes
| Std Par Ref |
5.6.8.9 |
| OID |
1.3.6.1.4.1.1206.4.2.3.5.8.1.9.2.2 |
| Object Name |
dmsMessageStatus |
| Syntax | Access | Status |
| INTEGER {enumeration} |
read-write |
optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object |
4 (valid) |
Success |
| 2 - Set Object to Min. Value |
4 (valid) |
Success |
| 3 - Set Object to Max. Value |
5 (error) |
Success |
| 4 - Attempt Write to Read-Only Object |
|
Skipped - Not read only |
| 5 - Attempt Read of Non-Accessible Object |
|
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
|
Skipped - no Minimum |
| 7 - Attempt to Set Value < Min. |
|
Skipped - no Minimum |
| 8 - Restore Object to Original Value |
|
Failed - GenErr |
Overall Test Case Results: Passed
Object Test Case TC-O-215
VDOT Implemented: Yes
| Std Par Ref |
5.6.8.9 |
| OID |
1.3.6.1.4.1.1206.4.2.3.5.8.1.9.3.1 |
| Object Name |
dmsMessageStatus |
| Syntax | Access | Status |
| INTEGER {enumeration} |
read-write |
optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object |
4 (valid) |
Success |
| 2 - Set Object to Min. Value |
4 (valid) |
Success |
| 3 - Set Object to Max. Value |
4 (valid) |
Success |
| 4 - Attempt Write to Read-Only Object |
|
Skipped - Not read only |
| 5 - Attempt Read of Non-Accessible Object |
|
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
|
Skipped - no Minimum |
| 7 - Attempt to Set Value < Min. |
|
Skipped - no Minimum |
| 8 - Restore Object to Original Value |
|
Failed - GenErr |
Overall Test Case Results: Passed
Object Test Case TC-O-216
VDOT Implemented: Yes
| Std Par Ref |
5.6.8.9 |
| OID |
1.3.6.1.4.1.1206.4.2.3.5.8.1.9.3.2 |
| Object Name |
dmsMessageStatus |
| Syntax | Access | Status |
| INTEGER {enumeration} |
read-write |
optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object |
4 (valid) |
Success |
| 2 - Set Object to Min. Value |
4 (valid) |
Success |
| 3 - Set Object to Max. Value |
4 (valid) |
Success |
| 4 - Attempt Write to Read-Only Object |
|
Skipped - Not read only |
| 5 - Attempt Read of Non-Accessible Object |
|
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
|
Skipped - no Minimum |
| 7 - Attempt to Set Value < Min. |
|
Skipped - no Minimum |
| 8 - Restore Object to Original Value |
|
Failed - GenErr |
Overall Test Case Results: Passed
Object Test Case TC-O-217
VDOT Implemented: Yes
| Std Par Ref |
5.6.8.9 |
| OID |
1.3.6.1.4.1.1206.4.2.3.5.8.1.9.4.1 |
| Object Name |
dmsMessageStatus |
| Syntax | Access | Status |
| INTEGER {enumeration} |
read-write |
optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object |
4 (valid) |
Success |
| 2 - Set Object to Min. Value |
4 (valid) |
Success |
| 3 - Set Object to Max. Value |
4 (valid) |
Success |
| 4 - Attempt Write to Read-Only Object |
|
Skipped - Not read only |
| 5 - Attempt Read of Non-Accessible Object |
|
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
|
Skipped - no Minimum |
| 7 - Attempt to Set Value < Min. |
|
Skipped - no Minimum |
| 8 - Restore Object to Original Value |
|
Failed - GenErr |
Overall Test Case Results: Passed
Object Test Case TC-O-218
VDOT Implemented: Yes
| Std Par Ref |
5.6.8.9 |
| OID |
1.3.6.1.4.1.1206.4.2.3.5.8.1.9.4.2 |
| Object Name |
dmsMessageStatus |
| Syntax | Access | Status |
| INTEGER {enumeration} |
read-write |
optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object |
1 (notUsed) |
Success |
| 2 - Set Object to Min. Value |
1 (notUsed) |
Success |
| 3 - Set Object to Max. Value |
1 (notUsed) |
Success |
| 4 - Attempt Write to Read-Only Object |
|
Skipped - Not read only |
| 5 - Attempt Read of Non-Accessible Object |
|
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
|
Skipped - no Minimum |
| 7 - Attempt to Set Value < Min. |
|
Skipped - no Minimum |
| 8 - Restore Object to Original Value |
|
Failed - GenErr |
Overall Test Case Results: Passed
Object Test Case TC-O-219
VDOT Implemented: Yes
| Std Par Ref |
5.6.8.9 |
| OID |
1.3.6.1.4.1.1206.4.2.3.5.8.1.9.5.1 |
| Object Name |
dmsMessageStatus |
| Syntax | Access | Status |
| INTEGER {enumeration} |
read-write |
optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object |
1 (notUsed) |
Success |
| 2 - Set Object to Min. Value |
1 (notUsed) |
Success |
| 3 - Set Object to Max. Value |
1 (notUsed) |
Success |
| 4 - Attempt Write to Read-Only Object |
|
Skipped - Not read only |
| 5 - Attempt Read of Non-Accessible Object |
|
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
|
Skipped - no Minimum |
| 7 - Attempt to Set Value < Min. |
|
Skipped - no Minimum |
| 8 - Restore Object to Original Value |
|
Failed - GenErr |
Overall Test Case Results: Passed
Object Test Case TC-O-220
VDOT Implemented: Yes
| Std Par Ref |
5.6.8.9 |
| OID |
1.3.6.1.4.1.1206.4.2.3.5.8.1.9.5.2 |
| Object Name |
dmsMessageStatus |
| Syntax | Access | Status |
| INTEGER {enumeration} |
read-write |
optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object |
1 (notUsed) |
Success |
| 2 - Set Object to Min. Value |
1 (notUsed) |
Success |
| 3 - Set Object to Max. Value |
1 (notUsed) |
Success |
| 4 - Attempt Write to Read-Only Object |
|
Skipped - Not read only |
| 5 - Attempt Read of Non-Accessible Object |
|
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
|
Skipped - no Minimum |
| 7 - Attempt to Set Value < Min. |
|
Skipped - no Minimum |
| 8 - Restore Object to Original Value |
|
Failed - GenErr |
Overall Test Case Results: Passed
Object Test Case TC-O-221
VDOT Implemented: Yes
| Std Par Ref |
5.6.8.9 |
| OID |
1.3.6.1.4.1.1206.4.2.3.5.8.1.9.6.1 |
| Object Name |
dmsMessageStatus |
| Syntax | Access | Status |
| INTEGER {enumeration} |
read-write |
optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object |
4 (valid) |
Success |
| 2 - Set Object to Min. Value |
4 (valid) |
Success |
| 3 - Set Object to Max. Value |
4 (valid) |
Success |
| 4 - Attempt Write to Read-Only Object |
|
Skipped - Not read only |
| 5 - Attempt Read of Non-Accessible Object |
|
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
|
Skipped - no Minimum |
| 7 - Attempt to Set Value < Min. |
|
Skipped - no Minimum |
| 8 - Restore Object to Original Value |
|
Failed - GenErr |
Overall Test Case Results: Passed
Object Test Case TC-O-222
VDOT Implemented: Yes
| Std Par Ref |
5.6.8.9 |
| OID |
1.3.6.1.4.1.1206.4.2.3.5.8.1.9.6.2 |
| Object Name |
dmsMessageStatus |
| Syntax | Access | Status |
| INTEGER {enumeration} |
read-write |
optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object |
1 (notUsed) |
Success |
| 2 - Set Object to Min. Value |
1 (notUsed) |
Success |
| 3 - Set Object to Max. Value |
1 (notUsed) |
Success |
| 4 - Attempt Write to Read-Only Object |
|
Skipped - Not read only |
| 5 - Attempt Read of Non-Accessible Object |
|
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
|
Skipped - no Minimum |
| 7 - Attempt to Set Value < Min. |
|
Skipped - no Minimum |
| 8 - Restore Object to Original Value |
|
Failed - GenErr |
Overall Test Case Results: Passed
Object Test Case TC-O-223
VDOT Implemented: Yes
| Std Par Ref |
5.6.8.10 |
| OID |
1.3.6.1.4.1.1206.4.2.3.5.8.1.10.2.1 |
| Object Name |
dmsMessageName |
| Syntax | Access | Status |
| DisplayString (SIZE (0..64)) |
read-write |
optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object |
|
Success |
| 2 - Set Object to Min. Value |
|
Success |
| 3 - Set Object to Max. Value |
|
Success |
| 4 - Attempt Write to Read-Only Object |
00 |
Skipped - Not read only |
| 5 - Attempt Read of Non-Accessible Object |
00 |
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
1 |
Success - did not write greater than Max |
| 7 - Attempt to Set Value < Min. |
-1 |
Success - did not write less than Min |
| 8 - Restore Object to Original Value |
00 |
Failed - GenErr |
Overall Test Case Results: Passed
Object Test Case TC-O-224
VDOT Implemented: Yes
| Std Par Ref |
5.6.8.10 |
| OID |
1.3.6.1.4.1.1206.4.2.3.5.8.1.10.2.2 |
| Object Name |
dmsMessageName |
| Syntax | Access | Status |
| DisplayString (SIZE (0..64)) |
read-write |
optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object |
|
Success |
| 2 - Set Object to Min. Value |
|
Success |
| 3 - Set Object to Max. Value |
|
Success |
| 4 - Attempt Write to Read-Only Object |
00 |
Skipped - Not read only |
| 5 - Attempt Read of Non-Accessible Object |
00 |
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
1 |
Success - did not write greater than Max |
| 7 - Attempt to Set Value < Min. |
-1 |
Success - did not write less than Min |
| 8 - Restore Object to Original Value |
00 |
Failed - GenErr |
Overall Test Case Results: Passed
Object Test Case TC-O-225
VDOT Implemented: Yes
| Std Par Ref |
5.6.8.10 |
| OID |
1.3.6.1.4.1.1206.4.2.3.5.8.1.10.3.1 |
| Object Name |
dmsMessageName |
| Syntax | Access | Status |
| DisplayString (SIZE (0..64)) |
read-write |
optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object |
|
Success |
| 2 - Set Object to Min. Value |
|
Success |
| 3 - Set Object to Max. Value |
|
Success |
| 4 - Attempt Write to Read-Only Object |
00 |
Skipped - Not read only |
| 5 - Attempt Read of Non-Accessible Object |
00 |
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
1 |
Success - did not write greater than Max |
| 7 - Attempt to Set Value < Min. |
-1 |
Success - did not write less than Min |
| 8 - Restore Object to Original Value |
00 |
Failed - GenErr |
Overall Test Case Results: Passed
Object Test Case TC-O-226
VDOT Implemented: Yes
| Std Par Ref |
5.6.8.10 |
| OID |
1.3.6.1.4.1.1206.4.2.3.5.8.1.10.3.2 |
| Object Name |
dmsMessageName |
| Syntax | Access | Status |
| DisplayString (SIZE (0..64)) |
read-write |
optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object |
|
Success |
| 2 - Set Object to Min. Value |
|
Success |
| 3 - Set Object to Max. Value |
|
Success |
| 4 - Attempt Write to Read-Only Object |
00 |
Skipped - Not read only |
| 5 - Attempt Read of Non-Accessible Object |
00 |
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
1 |
Success - did not write greater than Max |
| 7 - Attempt to Set Value < Min. |
-1 |
Success - did not write less than Min |
| 8 - Restore Object to Original Value |
00 |
Failed - GenErr |
Overall Test Case Results: Passed
Object Test Case TC-O-227
VDOT Implemented: Yes
| Std Par Ref |
5.6.8.10 |
| OID |
1.3.6.1.4.1.1206.4.2.3.5.8.1.10.4.1 |
| Object Name |
dmsMessageName |
| Syntax | Access | Status |
| DisplayString (SIZE (0..64)) |
read-write |
optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object |
V1 |
Success |
| 2 - Set Object to Min. Value |
V1 |
Success |
| 3 - Set Object to Max. Value |
V1 |
Success |
| 4 - Attempt Write to Read-Only Object |
00 |
Skipped - Not read only |
| 5 - Attempt Read of Non-Accessible Object |
00 |
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
1 |
Success - did not write greater than Max |
| 7 - Attempt to Set Value < Min. |
-1 |
Success - did not write less than Min |
| 8 - Restore Object to Original Value |
00 |
Failed - GenErr |
Overall Test Case Results: Passed
Object Test Case TC-O-228
VDOT Implemented: Yes
| Std Par Ref |
5.6.8.10 |
| OID |
1.3.6.1.4.1.1206.4.2.3.5.8.1.10.4.2 |
| Object Name |
dmsMessageName |
| Syntax | Access | Status |
| DisplayString (SIZE (0..64)) |
read-write |
optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object |
|
Success |
| 2 - Set Object to Min. Value |
|
Success |
| 3 - Set Object to Max. Value |
|
Success |
| 4 - Attempt Write to Read-Only Object |
00 |
Skipped - Not read only |
| 5 - Attempt Read of Non-Accessible Object |
00 |
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
1 |
Success - did not write greater than Max |
| 7 - Attempt to Set Value < Min. |
-1 |
Success - did not write less than Min |
| 8 - Restore Object to Original Value |
00 |
Failed - GenErr |
Overall Test Case Results: Passed
Object Test Case TC-O-229
VDOT Implemented: Yes
| Std Par Ref |
5.6.8.10 |
| OID |
1.3.6.1.4.1.1206.4.2.3.5.8.1.10.5.1 |
| Object Name |
dmsMessageName |
| Syntax | Access | Status |
| DisplayString (SIZE (0..64)) |
read-write |
optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object |
|
Success |
| 2 - Set Object to Min. Value |
|
Success |
| 3 - Set Object to Max. Value |
|
Success |
| 4 - Attempt Write to Read-Only Object |
00 |
Skipped - Not read only |
| 5 - Attempt Read of Non-Accessible Object |
00 |
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
1 |
Success - did not write greater than Max |
| 7 - Attempt to Set Value < Min. |
-1 |
Success - did not write less than Min |
| 8 - Restore Object to Original Value |
00 |
Failed - GenErr |
Overall Test Case Results: Passed
Object Test Case TC-O-230
VDOT Implemented: Yes
| Std Par Ref |
5.6.8.10 |
| OID |
1.3.6.1.4.1.1206.4.2.3.5.8.1.10.5.2 |
| Object Name |
dmsMessageName |
| Syntax | Access | Status |
| DisplayString (SIZE (0..64)) |
read-write |
optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object |
|
Success |
| 2 - Set Object to Min. Value |
|
Success |
| 3 - Set Object to Max. Value |
|
Success |
| 4 - Attempt Write to Read-Only Object |
00 |
Skipped - Not read only |
| 5 - Attempt Read of Non-Accessible Object |
00 |
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
1 |
Success - did not write greater than Max |
| 7 - Attempt to Set Value < Min. |
-1 |
Success - did not write less than Min |
| 8 - Restore Object to Original Value |
00 |
Failed - GenErr |
Overall Test Case Results: Passed
Object Test Case TC-O-231
VDOT Implemented: Yes
| Std Par Ref |
5.6.8.10 |
| OID |
1.3.6.1.4.1.1206.4.2.3.5.8.1.10.6.1 |
| Object Name |
dmsMessageName |
| Syntax | Access | Status |
| DisplayString (SIZE (0..64)) |
read-write |
optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object |
|
Success |
| 2 - Set Object to Min. Value |
|
Success |
| 3 - Set Object to Max. Value |
|
Success |
| 4 - Attempt Write to Read-Only Object |
00 |
Skipped - Not read only |
| 5 - Attempt Read of Non-Accessible Object |
00 |
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
1 |
Success - did not write greater than Max |
| 7 - Attempt to Set Value < Min. |
-1 |
Success - did not write less than Min |
| 8 - Restore Object to Original Value |
00 |
Failed - GenErr |
Overall Test Case Results: Passed
Object Test Case TC-O-232
VDOT Implemented: Yes
| Std Par Ref |
5.6.8.10 |
| OID |
1.3.6.1.4.1.1206.4.2.3.5.8.1.10.6.2 |
| Object Name |
dmsMessageName |
| Syntax | Access | Status |
| DisplayString (SIZE (0..64)) |
read-write |
optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object |
|
Success |
| 2 - Set Object to Min. Value |
|
Success |
| 3 - Set Object to Max. Value |
|
Success |
| 4 - Attempt Write to Read-Only Object |
00 |
Skipped - Not read only |
| 5 - Attempt Read of Non-Accessible Object |
00 |
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
1 |
Success - did not write greater than Max |
| 7 - Attempt to Set Value < Min. |
-1 |
Success - did not write less than Min |
| 8 - Restore Object to Original Value |
00 |
Failed - GenErr |
Overall Test Case Results: Passed
Object Test Case TC-O-233
VDOT Implemented: Yes
| Std Par Ref |
5.6.9 |
| OID |
1.3.6.1.4.1.1206.4.2.3.5.9.0 |
| Object Name |
dmsValidateMessageError |
| Syntax | Access | Status |
| INTEGER {enumeration} |
read-only |
optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object |
2 (none) |
Success |
| 2 - Set Object to Min. Value |
2 (none) |
Success |
| 3 - Set Object to Max. Value |
2 (none) |
Success |
| 4 - Attempt Write to Read-Only Object |
|
Failed - NoSuchName |
| 5 - Attempt Read of Non-Accessible Object |
|
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
|
Skipped - not writable |
| 7 - Attempt to Set Value < Min. |
|
Skipped - not writable |
| 8 - Restore Object to Original Value |
|
Skipped - Not writable |
Overall Test Case Results: Passed
Object Test Case TC-O-234
VDOT Implemented: Yes
| Std Par Ref |
5.7.1 |
| OID |
1.3.6.1.4.1.1206.4.2.3.6.1.0 |
| Object Name |
dmsControlMode |
| Syntax | Access | Status |
| INTEGER {enumeration} |
read-write |
optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object |
4 (central) |
Success |
| 2 - Set Object to Min. Value |
4 (central) |
Success |
| 3 - Set Object to Max. Value |
4 (central) |
Success |
| 4 - Attempt Write to Read-Only Object |
|
Skipped - Not read only |
| 5 - Attempt Read of Non-Accessible Object |
|
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
|
Skipped - no Minimum |
| 7 - Attempt to Set Value < Min. |
|
Skipped - no Minimum |
| 8 - Restore Object to Original Value |
|
Failed - BadValue |
Overall Test Case Results: Passed
Object Test Case TC-O-235
VDOT Implemented: Yes
| Std Par Ref |
5.7.2 |
| OID |
1.3.6.1.4.1.1206.4.2.3.6.2.0 |
| Object Name |
dmsSWReset |
| Syntax | Access | Status |
| INTEGER (0..1) |
read-write |
optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object |
0 |
Success |
| 2 - Set Object to Min. Value |
0 |
Success |
| 3 - Set Object to Max. Value |
0 |
Success |
| 4 - Attempt Write to Read-Only Object |
|
Skipped - Not read only |
| 5 - Attempt Read of Non-Accessible Object |
|
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
2 |
Success - did not write greater than Max |
| 7 - Attempt to Set Value < Min. |
-1 |
Success - did not write less than Min |
| 8 - Restore Object to Original Value |
0 |
Success |
Overall Test Case Results: Passed
Object Test Case TC-O-236
VDOT Implemented: Yes
| Std Par Ref |
5.7.3 |
| OID |
1.3.6.1.4.1.1206.4.2.3.6.3.0 |
| Object Name |
dmsActivateMessage |
| Syntax | Access | Status |
| MessageActivationCode |
read-write |
optional |
| Test Type | Test Value | Test Results |
| 1 - Read Initial Value of Object |
00 00 00 00 00 00 00 00 00 00 00 00 |
Success |
| 2 - Set Object to Min. Value |
00 00 00 00 00 00 00 00 00 00 00 00 |
Success |
| 3 - Set Object to Max. Value |
00 00 00 00 00 00 00 00 00 00 00 00 |
Success |
| 4 - Attempt Write to Read-Only Object |
00 |
Skipped - Not read only |
| 5 - Attempt Read of Non-Accessible Object |
00 |
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
00 |
Skipped - no Minimum |
| 7 - Attempt to Set Value < Min. |
00 |
Skipped - no Minimum |
| 8 - Restore Object to Original Value |
00 |
Failed - GenErr |
Overall Test Case Results: Passed
Object Test Case TC-O-237
VDOT Implemented: Yes
| Std Par Ref |
5.7.4 |
| OID |
1.3.6.1.4.1.1206.4.2.3.6.4.0 |
| Object Name |
dmsMessageTimeRemaining |
| Syntax | Access | Status |
| INTEGER (0..65535) |
read-write |
optional |
| Test Type | Test Value | Test Results |
| 1 - Read Initial Value of Object |
0 |
Success |
| 2 - Set Object to Min. Value |
0 |
Success |
| 3 - Set Object to Max. Value |
0 |
Success |
| 4 - Attempt Write to Read-Only Object |
|
Skipped - Not read only |
| 5 - Attempt Read of Non-Accessible Object |
|
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
65536 |
Success - did not write greater than Max |
| 7 - Attempt to Set Value < Min. |
-1 |
Failed - wrote less than Min |
| 8 - Restore Object to Original Value |
0 |
Success |
Overall Test Case Results: Passed
Object Test Case TC-O-238
VDOT Implemented: Yes
| Std Par Ref |
5.7.5 |
| OID |
1.3.6.1.4.1.1206.4.2.3.6.5.0 |
| Object Name |
dmsMsgTableSource |
| Syntax | Access | Status |
| MessageIDCode |
read-only |
optional |
| Test Type | Test Value | Test Results |
| 1 - Read Initial Value of Object |
00 00 00 00 00 |
Success |
| 2 - Set Object to Min. Value |
00 00 00 00 00 |
Success |
| 3 - Set Object to Max. Value |
00 00 00 00 00 |
Success |
| 4 - Attempt Write to Read-Only Object |
00 |
Failed - NoSuchName |
| 5 - Attempt Read of Non-Accessible Object |
00 |
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
00 |
Skipped - not writable |
| 7 - Attempt to Set Value < Min. |
00 |
Skipped - not writable |
| 8 - Restore Object to Original Value |
00 |
Skipped - Not writable |
Overall Test Case Results: Passed
Object Test Case TC-O-239
VDOT Implemented: Yes
| Std Par Ref |
5.7.6 |
| OID |
1.3.6.1.4.1.1206.4.2.3.6.6.0 |
| Object Name |
dmsMsgRequesterID |
| Syntax | Access | Status |
| IpAddress |
read-only |
optional |
| Test Type | Test Value | Test Results |
| 1 - Read Initial Value of Object |
00 00 00 00 |
Success |
| 2 - Set Object to Min. Value |
00 00 00 00 |
Success |
| 3 - Set Object to Max. Value |
00 00 00 00 |
Success |
| 4 - Attempt Write to Read-Only Object |
00 |
Failed - NoSuchName |
| 5 - Attempt Read of Non-Accessible Object |
00 |
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
00 |
Skipped - not writable |
| 7 - Attempt to Set Value < Min. |
00 |
Skipped - not writable |
| 8 - Restore Object to Original Value |
00 |
Skipped - Not writable |
Overall Test Case Results: Passed
Object Test Case TC-O-240
VDOT Implemented: Yes
| Std Par Ref |
5.7.7 |
| OID |
1.3.6.1.4.1.1206.4.2.3.6.7.0 |
| Object Name |
dmsMsgSourceMode |
| Syntax | Access | Status |
| INTEGER {enumeration} |
read-only |
optional |
| Test Type | Test Value | Test Results |
| 1 - Read Initial Value of Object |
1 (other) |
Success |
| 2 - Set Object to Min. Value |
10 (powerRecovery) |
Success |
| 3 - Set Object to Max. Value |
11 (reset) |
Success |
| 4 - Attempt Write to Read-Only Object |
|
Failed - NoSuchName |
| 5 - Attempt Read of Non-Accessible Object |
|
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
|
Skipped - not writable |
| 7 - Attempt to Set Value < Min. |
|
Skipped - not writable |
| 8 - Restore Object to Original Value |
|
Skipped - Not writable |
Overall Test Case Results: Passed
Object Test Case TC-O-241
VDOT Implemented: Yes
| Std Par Ref |
5.7.8 |
| OID |
1.3.6.1.4.1.1206.4.2.3.6.8.0 |
| Object Name |
dmsShortPowerRecoveryMessage |
| Syntax | Access | Status |
| MessageIDCode |
read-write |
optional |
| Test Type | Test Value | Test Results |
| 1 - Read Initial Value of Object |
07 00 FF 00 00 |
Success |
| 2 - Set Object to Min. Value |
07 00 FF 00 00 |
Success |
| 3 - Set Object to Max. Value |
07 00 FF 00 00 |
Success |
| 4 - Attempt Write to Read-Only Object |
00 |
Skipped - Not read only |
| 5 - Attempt Read of Non-Accessible Object |
00 |
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
00 |
Skipped - no Minimum |
| 7 - Attempt to Set Value < Min. |
00 |
Skipped - no Minimum |
| 8 - Restore Object to Original Value |
07 00 FF 00 00 |
Success |
Overall Test Case Results: Passed
Object Test Case TC-O-242
VDOT Implemented: Yes
| Std Par Ref |
5.7.9 |
| OID |
1.3.6.1.4.1.1206.4.2.3.6.9.0 |
| Object Name |
dmsLongPowerRecoveryMessage |
| Syntax | Access | Status |
| MessageIDCode |
read-write |
optional |
| Test Type | Test Value | Test Results |
| 1 - Read Initial Value of Object |
07 00 FF 00 00 |
Success |
| 2 - Set Object to Min. Value |
07 00 FF 00 00 |
Success |
| 3 - Set Object to Max. Value |
07 00 FF 00 00 |
Success |
| 4 - Attempt Write to Read-Only Object |
00 |
Skipped - Not read only |
| 5 - Attempt Read of Non-Accessible Object |
00 |
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
00 |
Skipped - no Minimum |
| 7 - Attempt to Set Value < Min. |
00 |
Skipped - no Minimum |
| 8 - Restore Object to Original Value |
07 00 FF 00 00 |
Success |
Overall Test Case Results: Passed
Object Test Case TC-O-243
VDOT Implemented: Yes
| Std Par Ref |
5.7.10 |
| OID |
1.3.6.1.4.1.1206.4.2.3.6.10.0 |
| Object Name |
dmsShortPowerLossTime |
| Syntax | Access | Status |
| INTEGER (0..65535) |
read-write |
optional |
| Test Type | Test Value | Test Results |
| 1 - Read Initial Value of Object |
0 |
Success |
| 2 - Set Object to Min. Value |
0 |
Success |
| 3 - Set Object to Max. Value |
65535 |
Success |
| 4 - Attempt Write to Read-Only Object |
|
Skipped - Not read only |
| 5 - Attempt Read of Non-Accessible Object |
|
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
65536 |
Success - did not write greater than Max |
| 7 - Attempt to Set Value < Min. |
-1 |
Failed - wrote less than Min |
| 8 - Restore Object to Original Value |
0 |
Success |
Overall Test Case Results: Passed
Object Test Case TC-O-244
VDOT Implemented: Yes
| Std Par Ref |
5.7.11 |
| OID |
1.3.6.1.4.1.1206.4.2.3.6.11.0 |
| Object Name |
dmsResetMessage |
| Syntax | Access | Status |
| MessageIDCode |
read-write |
optional |
| Test Type | Test Value | Test Results |
| 1 - Read Initial Value of Object |
07 00 FF 00 00 |
Success |
| 2 - Set Object to Min. Value |
07 00 FF 00 00 |
Success |
| 3 - Set Object to Max. Value |
07 00 FF 00 00 |
Success |
| 4 - Attempt Write to Read-Only Object |
00 |
Skipped - Not read only |
| 5 - Attempt Read of Non-Accessible Object |
00 |
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
00 |
Skipped - no Minimum |
| 7 - Attempt to Set Value < Min. |
00 |
Skipped - no Minimum |
| 8 - Restore Object to Original Value |
07 00 FF 00 00 |
Success |
Overall Test Case Results: Passed
Object Test Case TC-O-245
VDOT Implemented: Yes
| Std Par Ref |
5.7.12 |
| OID |
1.3.6.1.4.1.1206.4.2.3.6.12.0 |
| Object Name |
dmsCommunicationsLossMessage |
| Syntax | Access | Status |
| MessageIDCode |
read-write |
optional |
| Test Type | Test Value | Test Results |
| 1 - Read Initial Value of Object |
07 00 FF 00 00 |
Success |
| 2 - Set Object to Min. Value |
07 00 FF 00 00 |
Success |
| 3 - Set Object to Max. Value |
07 00 FF 00 00 |
Success |
| 4 - Attempt Write to Read-Only Object |
00 |
Skipped - Not read only |
| 5 - Attempt Read of Non-Accessible Object |
00 |
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
00 |
Skipped - no Minimum |
| 7 - Attempt to Set Value < Min. |
00 |
Skipped - no Minimum |
| 8 - Restore Object to Original Value |
07 00 FF 00 00 |
Success |
Overall Test Case Results: Passed
Object Test Case TC-O-246
VDOT Implemented: Yes
| Std Par Ref |
5.7.13 |
| OID |
1.3.6.1.4.1.1206.4.2.3.6.13.0 |
| Object Name |
dmsTimeCommLoss |
| Syntax | Access | Status |
| INTEGER (0..65535) |
read-write |
optional |
| Test Type | Test Value | Test Results |
| 1 - Read Initial Value of Object |
255 |
Success |
| 2 - Set Object to Min. Value |
0 |
Success |
| 3 - Set Object to Max. Value |
65535 |
Success |
| 4 - Attempt Write to Read-Only Object |
|
Skipped - Not read only |
| 5 - Attempt Read of Non-Accessible Object |
|
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
65536 |
Success - did not write greater than Max |
| 7 - Attempt to Set Value < Min. |
-1 |
Failed - wrote less than Min |
| 8 - Restore Object to Original Value |
|
Failed - TimeOut |
Overall Test Case Results: Passed
Object Test Case TC-O-247
VDOT Implemented: Yes
| Std Par Ref |
5.7.14 |
| OID |
1.3.6.1.4.1.1206.4.2.3.6.14.0 |
| Object Name |
dmsPowerLossMessage |
| Syntax | Access | Status |
| MessageIDCode |
read-write |
optional |
| Test Type | Test Value | Test Results |
| 1 - Read Initial Value of Object |
00 |
Failed - NoSuchName |
| 2 - Set Object to Min. Value |
00 |
Failed - NoSuchName |
| 3 - Set Object to Max. Value |
00 |
Failed - NoSuchName |
| 4 - Attempt Write to Read-Only Object |
00 |
Skipped - Not read only |
| 5 - Attempt Read of Non-Accessible Object |
00 |
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
00 |
Skipped - no Minimum |
| 7 - Attempt to Set Value < Min. |
00 |
Skipped - no Minimum |
| 8 - Restore Object to Original Value |
00 |
Failed - TimeOut |
Overall Test Case Results: Passed
Object Test Case TC-O-248
VDOT Implemented: Yes
| Std Par Ref |
5.7.15 |
| OID |
1.3.6.1.4.1.1206.4.2.3.6.15.0 |
| Object Name |
dmsEndDurationMessage |
| Syntax | Access | Status |
| MessageIDCode |
read-write |
optional |
| Test Type | Test Value | Test Results |
| 1 - Read Initial Value of Object |
07 00 FF 00 00 |
Success |
| 2 - Set Object to Min. Value |
07 00 FF 00 00 |
Success |
| 3 - Set Object to Max. Value |
07 00 FF 00 00 |
Success |
| 4 - Attempt Write to Read-Only Object |
00 |
Skipped - Not read only |
| 5 - Attempt Read of Non-Accessible Object |
00 |
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
00 |
Skipped - no Minimum |
| 7 - Attempt to Set Value < Min. |
00 |
Skipped - no Minimum |
| 8 - Restore Object to Original Value |
00 |
Failed - TimeOut |
Overall Test Case Results: Passed
Object Test Case TC-O-249
VDOT Implemented: Yes
| Std Par Ref |
5.7.16 |
| OID |
1.3.6.1.4.1.1206.4.2.3.6.16.0 |
| Object Name |
dmsMemoryMgmt |
| Syntax | Access | Status |
| INTEGER {enumeration} |
read-write |
optional |
| Test Type | Test Value | Test Results |
| 1 - Read Initial Value of Object |
2 (normal) |
Success |
| 2 - Set Object to Min. Value |
2 (normal) |
Success |
| 3 - Set Object to Max. Value |
2 (normal) |
Success |
| 4 - Attempt Write to Read-Only Object |
|
Skipped - Not read only |
| 5 - Attempt Read of Non-Accessible Object |
|
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
|
Skipped - no Minimum |
| 7 - Attempt to Set Value < Min. |
|
Skipped - no Minimum |
| 8 - Restore Object to Original Value |
|
Failed - TimeOut |
Overall Test Case Results: Passed
Object Test Case TC-O-250
VDOT Implemented: Yes
| Std Par Ref |
5.7.17 |
| OID |
1.3.6.1.4.1.1206.4.2.3.6.17.0 |
| Object Name |
dmsActivateMsgError |
| Syntax | Access | Status |
| INTEGER {enumeration} |
read-only |
optional |
| Test Type | Test Value | Test Results |
| 1 - Read Initial Value of Object |
2 (none) |
Success |
| 2 - Set Object to Min. Value |
2 (none) |
Success |
| 3 - Set Object to Max. Value |
2 (none) |
Success |
| 4 - Attempt Write to Read-Only Object |
|
Failed - NoSuchName |
| 5 - Attempt Read of Non-Accessible Object |
|
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
|
Skipped - not writable |
| 7 - Attempt to Set Value < Min. |
|
Skipped - not writable |
| 8 - Restore Object to Original Value |
|
Skipped - Not writable |
Overall Test Case Results: Passed
Object Test Case TC-O-251
VDOT Implemented: Yes
| Std Par Ref |
5.7.18 |
| OID |
1.3.6.1.4.1.1206.4.2.3.6.18.0 |
| Object Name |
dmsMultiSyntaxError |
| Syntax | Access | Status |
| INTEGER {enumeration} |
read-only |
optional |
| Test Type | Test Value | Test Results |
| 1 - Read Initial Value of Object |
2 (none) |
Success |
| 2 - Set Object to Min. Value |
2 (none) |
Success |
| 3 - Set Object to Max. Value |
2 (none) |
Success |
| 4 - Attempt Write to Read-Only Object |
|
Failed - NoSuchName |
| 5 - Attempt Read of Non-Accessible Object |
|
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
|
Skipped - not writable |
| 7 - Attempt to Set Value < Min. |
|
Skipped - not writable |
| 8 - Restore Object to Original Value |
|
Skipped - Not writable |
Overall Test Case Results: Passed
Object Test Case TC-O-252
VDOT Implemented: Yes
| Std Par Ref |
5.7.19 |
| OID |
1.3.6.1.4.1.1206.4.2.3.6.19.0 |
| Object Name |
dmsMultiSyntaxErrorPosition |
| Syntax | Access | Status |
| INTEGER (0..65535) |
read-only |
optional |
| Test Type | Test Value | Test Results |
| 1 - Read Initial Value of Object |
0 |
Success |
| 2 - Set Object to Min. Value |
0 |
Success |
| 3 - Set Object to Max. Value |
6 |
Success |
| 4 - Attempt Write to Read-Only Object |
|
Failed - NoSuchName |
| 5 - Attempt Read of Non-Accessible Object |
|
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
|
Skipped - not writable |
| 7 - Attempt to Set Value < Min. |
|
Skipped - not writable |
| 8 - Restore Object to Original Value |
|
Skipped - Not writable |
Overall Test Case Results: Passed
Object Test Case TC-O-253
VDOT Implemented: Yes
| Std Par Ref |
5.7.20 |
| OID |
1.3.6.1.4.1.1206.4.2.3.6.20.0 |
| Object Name |
dmsMultiOtherErrorDescription |
| Syntax | Access | Status |
| DisplayString (SIZE (0..50)) |
read-only |
optional |
| Test Type | Test Value | Test Results |
| 1 - Read Initial Value of Object |
|
Success |
| 2 - Set Object to Min. Value |
|
Success |
| 3 - Set Object to Max. Value |
|
Success |
| 4 - Attempt Write to Read-Only Object |
00 |
Failed - NoSuchName |
| 5 - Attempt Read of Non-Accessible Object |
00 |
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
00 |
Skipped - not writable |
| 7 - Attempt to Set Value < Min. |
00 |
Skipped - not writable |
| 8 - Restore Object to Original Value |
00 |
Skipped - Not writable |
Overall Test Case Results: Passed
Object Test Case TC-O-254
VDOT Implemented: Yes
| Std Par Ref |
5.7.21 |
| OID |
1.3.6.1.4.1.1206.4.2.3.6.21.0 |
| Object Name |
vmsPixelServiceDuration |
| Syntax | Access | Status |
| INTEGER (0..65535) |
read-write |
optional |
| Test Type | Test Value | Test Results |
| 1 - Read Initial Value of Object |
255 |
Success |
| 2 - Set Object to Min. Value |
255 |
Success |
| 3 - Set Object to Max. Value |
255 |
Success |
| 4 - Attempt Write to Read-Only Object |
|
Skipped - Not read only |
| 5 - Attempt Read of Non-Accessible Object |
|
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
65536 |
Success - did not write greater than Max |
| 7 - Attempt to Set Value < Min. |
-1 |
Failed - wrote less than Min |
| 8 - Restore Object to Original Value |
|
Failed - TimeOut |
Overall Test Case Results: Passed
Object Test Case TC-O-255
VDOT Implemented: Yes
| Std Par Ref |
5.7.22 |
| OID |
1.3.6.1.4.1.1206.4.2.3.6.22.0 |
| Object Name |
vmsPixelServiceFrequency |
| Syntax | Access | Status |
| INTEGER (0..1440) |
read-write |
optional |
| Test Type | Test Value | Test Results |
| 1 - Read Initial Value of Object |
255 |
Success |
| 2 - Set Object to Min. Value |
255 |
Success |
| 3 - Set Object to Max. Value |
255 |
Success |
| 4 - Attempt Write to Read-Only Object |
|
Skipped - Not read only |
| 5 - Attempt Read of Non-Accessible Object |
|
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
1441 |
Success - did not write greater than Max |
| 7 - Attempt to Set Value < Min. |
-1 |
Failed - wrote less than Min |
| 8 - Restore Object to Original Value |
|
Failed - TimeOut |
Overall Test Case Results: Passed
Object Test Case TC-O-256
VDOT Implemented: Yes
| Std Par Ref |
5.7.23 |
| OID |
1.3.6.1.4.1.1206.4.2.3.6.23.0 |
| Object Name |
vmsPixelServiceTime |
| Syntax | Access | Status |
| INTEGER (0..1440) |
read-write |
optional |
| Test Type | Test Value | Test Results |
| 1 - Read Initial Value of Object |
0 |
Success |
| 2 - Set Object to Min. Value |
0 |
Success |
| 3 - Set Object to Max. Value |
0 |
Success |
| 4 - Attempt Write to Read-Only Object |
|
Skipped - Not read only |
| 5 - Attempt Read of Non-Accessible Object |
|
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
1441 |
Success - did not write greater than Max |
| 7 - Attempt to Set Value < Min. |
-1 |
Failed - wrote less than Min |
| 8 - Restore Object to Original Value |
0 |
Success |
Overall Test Case Results: Passed
Object Test Case TC-O-257
VDOT Implemented: Yes
| Std Par Ref |
5.7.24 |
| OID |
1.3.6.1.4.1.1206.4.2.3.6.26.0 |
| Object Name |
dmsActivateErrorMsgCode |
| Syntax | Access | Status |
| MessageActivationCode |
read-only |
optional |
| Test Type | Test Value | Test Results |
| 1 - Read Initial Value of Object |
00 00 00 00 00 00 00 00 00 00 00 00 |
Success |
| 2 - Set Object to Min. Value |
00 00 00 00 00 00 00 00 00 00 00 00 |
Success |
| 3 - Set Object to Max. Value |
00 00 00 00 00 00 00 00 00 00 00 00 |
Success |
| 4 - Attempt Write to Read-Only Object |
00 |
Failed - NoSuchName |
| 5 - Attempt Read of Non-Accessible Object |
00 |
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
00 |
Skipped - not writable |
| 7 - Attempt to Set Value < Min. |
00 |
Skipped - not writable |
| 8 - Restore Object to Original Value |
00 |
Skipped - Not writable |
Overall Test Case Results: Passed
Object Test Case TC-O-258
VDOT Implemented: Yes
| Std Par Ref |
5.7.25.1 |
| OID |
1.3.6.1.4.1.1206.4.2.3.6.25.1.0 |
| Object Name |
eventControlMaxTriggers |
| Syntax | Access | Status |
| INTEGER (0..255) |
read-only |
optional |
| Test Type | Test Value | Test Results |
| 1 - Read Initial Value of Object |
|
Failed - NoSuchName |
| 2 - Set Object to Min. Value |
|
Failed - NoSuchName |
| 3 - Set Object to Max. Value |
|
Failed - NoSuchName |
| 5 - Attempt Read of Non-Accessible Object |
|
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
|
Skipped - not writable |
| 7 - Attempt to Set Value < Min. |
|
Skipped - not writable |
| 8 - Restore Object to Original Value |
|
Skipped - Not writable |
Overall Test Case Results: Passed
Object Test Case TC-O-259
VDOT Implemented: Yes
| Std Par Ref |
5.7.25.2 |
| OID |
1.3.6.1.4.1.1206.4.2.3.6.25.2.0 |
| Object Name |
eventControlNumTriggers |
| Syntax | Access | Status |
| INTEGER (0..255) |
read-only |
optional |
| Test Type | Test Value | Test Results |
| 1 - Read Initial Value of Object |
|
Failed - NoSuchName |
| 2 - Set Object to Min. Value |
|
Failed - NoSuchName |
| 3 - Set Object to Max. Value |
|
Failed - NoSuchName |
| 5 - Attempt Read of Non-Accessible Object |
|
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
|
Skipped - not writable |
| 7 - Attempt to Set Value < Min. |
|
Skipped - not writable |
| 8 - Restore Object to Original Value |
|
Skipped - Not writable |
Overall Test Case Results: Passed
Object Test Case TC-O-260
VDOT Implemented: Yes
| Std Par Ref |
5.7.25.3.1 |
| OID |
1.3.6.1.4.1.1206.4.2.3.6.25.3.1.1.1 |
| Object Name |
eventControlConfigNumber |
| Syntax | Access | Status |
| INTEGER (1..255) |
read-only |
optional |
| Test Type | Test Value | Test Results |
| 1 - Read Initial Value of Object |
|
Failed - NoSuchName |
| 2 - Set Object to Min. Value |
|
Failed - NoSuchName |
| 3 - Set Object to Max. Value |
|
Failed - NoSuchName |
| 5 - Attempt Read of Non-Accessible Object |
|
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
|
Skipped - not writable |
| 7 - Attempt to Set Value < Min. |
|
Skipped - not writable |
| 8 - Restore Object to Original Value |
|
Skipped - Not writable |
Overall Test Case Results: Passed
Object Test Case TC-O-261
VDOT Implemented: Yes
| Std Par Ref |
5.7.25.3.2 |
| OID |
1.3.6.1.4.1.1206.4.2.3.6.25.3.1.2.1 |
| Object Name |
eventControlMonitoredObject |
| Syntax | Access | Status |
| OBJECT IDENTIFIER |
read-write |
optional |
| Test Type | Test Value | Test Results |
| 1 - Read Initial Value of Object |
|
Failed - NoSuchName |
| 2 - Set Object to Min. Value |
|
Failed - NoSuchName |
| 3 - Set Object to Max. Value |
|
Failed - NoSuchName |
| 4 - Attempt Write to Read-Only Object |
|
Skipped - Not read only |
| 5 - Attempt Read of Non-Accessible Object |
|
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
|
Skipped - no Minimum |
| 7 - Attempt to Set Value < Min. |
|
Skipped - no Minimum |
| 8 - Restore Object to Original Value |
|
Failed - NoSuchName |
Overall Test Case Results: Passed
Object Test Case TC-O-262
VDOT Implemented: Yes
| Std Par Ref |
5.7.25.3.3 |
| OID |
1.3.6.1.4.1.1206.4.2.3.6.25.3.1.3.1 |
| Object Name |
eventControlConfigOperator |
| Syntax | Access | Status |
| INTEGER {enumeration} |
read-write |
optional |
| Test Type | Test Value | Test Results |
| 1 - Read Initial Value of Object |
|
Failed - NoSuchName |
| 2 - Set Object to Min. Value |
|
Failed - NoSuchName |
| 3 - Set Object to Max. Value |
|
Failed - NoSuchName |
| 4 - Attempt Write to Read-Only Object |
|
Skipped - Not read only |
| 5 - Attempt Read of Non-Accessible Object |
|
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
|
Skipped - no Minimum |
| 7 - Attempt to Set Value < Min. |
|
Skipped - no Minimum |
Overall Test Case Results: Passed
Object Test Case TC-O-263
VDOT Implemented: Yes
| Std Par Ref |
5.7.25.3.4 |
| OID |
1.3.6.1.4.1.1206.4.2.3.6.25.3.1.4.1 |
| Object Name |
eventControlCompareValue1 |
| Syntax | Access | Status |
| INTEGER (0.. 4294967295) |
read-write |
optional |
| Test Type | Test Value | Test Results |
| 1 - Read Initial Value of Object |
|
Failed - NoSuchName |
| 2 - Set Object to Min. Value |
|
Failed - NoSuchName |
| 3 - Set Object to Max. Value |
|
Failed - NoSuchName |
| 4 - Attempt Write to Read-Only Object |
|
Skipped - Not read only |
| 5 - Attempt Read of Non-Accessible Object |
|
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
4294967296 |
Success - did not write greater than Max |
| 7 - Attempt to Set Value < Min. |
-1 |
Success - did not write less than Min |
Overall Test Case Results: Passed
Object Test Case TC-O-264
VDOT Implemented: Yes
| Std Par Ref |
5.7.25.3.5 |
| OID |
1.3.6.1.4.1.1206.4.2.3.6.25.3.1.5.1 |
| Object Name |
eventControlCompareValue2 |
| Syntax | Access | Status |
| INTEGER (0.. 4294967295) |
read-write |
optional |
| Test Type | Test Value | Test Results |
| 1 - Read Initial Value of Object |
|
Failed - NoSuchName |
| 2 - Set Object to Min. Value |
|
Failed - NoSuchName |
| 3 - Set Object to Max. Value |
|
Failed - NoSuchName |
| 4 - Attempt Write to Read-Only Object |
|
Skipped - Not read only |
| 5 - Attempt Read of Non-Accessible Object |
|
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
4294967296 |
Success - did not write greater than Max |
| 7 - Attempt to Set Value < Min. |
-1 |
Success - did not write less than Min |
Overall Test Case Results: Passed
Object Test Case TC-O-265
VDOT Implemented: Yes
| Std Par Ref |
5.7.25.3.6 |
| OID |
1.3.6.1.4.1.1206.4.2.3.6.25.3.1.6.1 |
| Object Name |
eventControlCompareObject |
| Syntax | Access | Status |
| OBJECT IDENTIFIER |
read-write |
optional |
| Test Type | Test Value | Test Results |
| 1 - Read Initial Value of Object |
|
Failed - NoSuchName |
| 2 - Set Object to Min. Value |
|
Failed - NoSuchName |
| 3 - Set Object to Max. Value |
|
Failed - NoSuchName |
| 4 - Attempt Write to Read-Only Object |
|
Skipped - Not read only |
| 5 - Attempt Read of Non-Accessible Object |
|
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
|
Skipped - no Minimum |
| 7 - Attempt to Set Value < Min. |
|
Skipped - no Minimum |
| 8 - Restore Object to Original Value |
|
Failed - NoSuchName |
Overall Test Case Results: Passed
Object Test Case TC-O-266
VDOT Implemented: Yes
| Std Par Ref |
5.7.25.3.7 |
| OID |
1.3.6.1.4.1.1206.4.2.3.6.25.3.1.7.1 |
| Object Name |
eventControlDelay |
| Syntax | Access | Status |
| INTEGER (-2147483647..2147483647) |
read-write |
optional |
| Test Type | Test Value | Test Results |
| 1 - Read Initial Value of Object |
|
Failed - NoSuchName |
| 2 - Set Object to Min. Value |
|
Failed - NoSuchName |
| 3 - Set Object to Max. Value |
|
Failed - NoSuchName |
| 4 - Attempt Write to Read-Only Object |
|
Skipped - Not read only |
| 5 - Attempt Read of Non-Accessible Object |
|
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
2147483648 |
Success - did not write greater than Max |
| 7 - Attempt to Set Value < Min. |
-2147483648 |
Success - did not write less than Min |
Overall Test Case Results: Passed
Object Test Case TC-O-267
VDOT Implemented: Yes
| Std Par Ref |
5.7.25.3.8 |
| OID |
1.3.6.1.4.1.1206.4.2.3.6.25.3.1.8.1 |
| Object Name |
eventControlMessageCode |
| Syntax | Access | Status |
| OCTET STRING |
read-write |
optional |
| Test Type | Test Value | Test Results |
| 1 - Read Initial Value of Object |
00 |
Failed - NoSuchName |
| 2 - Set Object to Min. Value |
00 |
Failed - NoSuchName |
| 3 - Set Object to Max. Value |
00 |
Failed - NoSuchName |
| 4 - Attempt Write to Read-Only Object |
00 |
Skipped - Not read only |
| 5 - Attempt Read of Non-Accessible Object |
00 |
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
00 |
Skipped - no Minimum |
| 7 - Attempt to Set Value < Min. |
00 |
Skipped - no Minimum |
| 8 - Restore Object to Original Value |
00 |
Failed - NoSuchName |
Overall Test Case Results: Passed
Object Test Case TC-O-268
VDOT Implemented: Yes
| Std Par Ref |
5.7.25.3.9 |
| OID |
1.3.6.1.4.1.1206.4.2.3.6.25.3.1.9.1 |
| Object Name |
eventControlTriggerMode |
| Syntax | Access | Status |
| INTEGER {enumeration} |
read-write |
optional |
| Test Type | Test Value | Test Results |
| 1 - Read Initial Value of Object |
|
Failed - NoSuchName |
| 2 - Set Object to Min. Value |
|
Failed - NoSuchName |
| 3 - Set Object to Max. Value |
|
Failed - NoSuchName |
| 4 - Attempt Write to Read-Only Object |
|
Skipped - Not read only |
| 5 - Attempt Read of Non-Accessible Object |
|
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
|
Skipped - no Minimum |
| 7 - Attempt to Set Value < Min. |
|
Skipped - no Minimum |
Overall Test Case Results: Passed
Object Test Case TC-O-269
VDOT Implemented: Yes
| Std Par Ref |
5.7.26 |
| OID |
1.3.6.1.4.1.1206.4.2.3.6.27.0 |
| Object Name |
dmsActivateMessageState |
| Syntax | Access | Status |
| INTEGER {enumeration} |
read-only |
optional |
| Test Type | Test Value | Test Results |
| 1 - Read Initial Value of Object |
|
Failed - NoSuchName |
| 2 - Set Object to Min. Value |
|
Failed - NoSuchName |
| 3 - Set Object to Max. Value |
|
Failed - NoSuchName |
| 5 - Attempt Read of Non-Accessible Object |
|
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
|
Skipped - not writable |
| 7 - Attempt to Set Value < Min. |
|
Skipped - not writable |
| 8 - Restore Object to Original Value |
|
Skipped - Not writable |
Overall Test Case Results: Passed
Object Test Case TC-O-270
VDOT Implemented: Yes
| Std Par Ref |
5.8.1 |
| OID |
1.3.6.1.4.1.1206.4.2.3.7.1.0 |
| Object Name |
dmsIllumControl |
| Syntax | Access | Status |
| INTEGER {enumeration} |
read-write |
optional |
| Test Type | Test Value | Test Results |
| 1 - Read Initial Value of Object |
2 (photocell) |
Success |
| 2 - Set Object to Min. Value |
2 (photocell) |
Success |
| 3 - Set Object to Max. Value |
2 (photocell) |
Success |
| 4 - Attempt Write to Read-Only Object |
|
Skipped - Not read only |
| 5 - Attempt Read of Non-Accessible Object |
|
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
|
Skipped - no Minimum |
| 7 - Attempt to Set Value < Min. |
|
Skipped - no Minimum |
| 8 - Restore Object to Original Value |
2 (photocell) |
Success |
Overall Test Case Results: Passed
Object Test Case TC-O-271
VDOT Implemented: Yes
| Std Par Ref |
5.8.2 |
| OID |
1.3.6.1.4.1.1206.4.2.3.7.2.0 |
| Object Name |
dmsIllumMaxPhotocellLevel |
| Syntax | Access | Status |
| INTEGER (0..65535) |
read-only |
optional |
| Test Type | Test Value | Test Results |
| 1 - Read Initial Value of Object |
65535 |
Success |
| 2 - Set Object to Min. Value |
65535 |
Success |
| 3 - Set Object to Max. Value |
65535 |
Success |
| 4 - Attempt Write to Read-Only Object |
|
Failed - NoSuchName |
| 5 - Attempt Read of Non-Accessible Object |
|
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
|
Skipped - not writable |
| 7 - Attempt to Set Value < Min. |
|
Skipped - not writable |
| 8 - Restore Object to Original Value |
|
Skipped - Not writable |
Overall Test Case Results: Passed
Object Test Case TC-O-272
VDOT Implemented: Yes
| Std Par Ref |
5.8.3 |
| OID |
1.3.6.1.4.1.1206.4.2.3.7.3.0 |
| Object Name |
dmsIllumPhotocellLevelStatus |
| Syntax | Access | Status |
| INTEGER (0..65535) |
read-only |
optional |
| Test Type | Test Value | Test Results |
| 1 - Read Initial Value of Object |
0 |
Success |
| 2 - Set Object to Min. Value |
0 |
Success |
| 3 - Set Object to Max. Value |
0 |
Success |
| 4 - Attempt Write to Read-Only Object |
|
Failed - NoSuchName |
| 5 - Attempt Read of Non-Accessible Object |
|
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
|
Skipped - not writable |
| 7 - Attempt to Set Value < Min. |
|
Skipped - not writable |
| 8 - Restore Object to Original Value |
|
Skipped - Not writable |
Overall Test Case Results: Passed
Object Test Case TC-O-273
VDOT Implemented: Yes
| Std Par Ref |
5.8.4 |
| OID |
1.3.6.1.4.1.1206.4.2.3.7.4.0 |
| Object Name |
dmsIllumNumBrightLevels |
| Syntax | Access | Status |
| INTEGER (0..255) |
read-only |
optional |
| Test Type | Test Value | Test Results |
| 1 - Read Initial Value of Object |
16 |
Success |
| 2 - Set Object to Min. Value |
16 |
Success |
| 3 - Set Object to Max. Value |
16 |
Success |
| 4 - Attempt Write to Read-Only Object |
|
Failed - NoSuchName |
| 5 - Attempt Read of Non-Accessible Object |
|
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
|
Skipped - not writable |
| 7 - Attempt to Set Value < Min. |
|
Skipped - not writable |
| 8 - Restore Object to Original Value |
|
Skipped - Not writable |
Overall Test Case Results: Passed
Object Test Case TC-O-274
VDOT Implemented: Yes
| Std Par Ref |
5.8.5 |
| OID |
1.3.6.1.4.1.1206.4.2.3.7.5.0 |
| Object Name |
dmsIllumBrightLevelStatus |
| Syntax | Access | Status |
| INTEGER (0..255) |
read-only |
optional |
| Test Type | Test Value | Test Results |
| 1 - Read Initial Value of Object |
1 |
Success |
| 2 - Set Object to Min. Value |
1 |
Success |
| 3 - Set Object to Max. Value |
1 |
Success |
| 4 - Attempt Write to Read-Only Object |
|
Failed - NoSuchName |
| 5 - Attempt Read of Non-Accessible Object |
|
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
|
Skipped - not writable |
| 7 - Attempt to Set Value < Min. |
|
Skipped - not writable |
| 8 - Restore Object to Original Value |
|
Skipped - Not writable |
Overall Test Case Results: Passed
Object Test Case TC-O-275
VDOT Implemented: Yes
| Std Par Ref |
5.8.6 |
| OID |
1.3.6.1.4.1.1206.4.2.3.7.6.0 |
| Object Name |
dmsIllumManLevel |
| Syntax | Access | Status |
| INTEGER (0..255) |
read-write |
optional |
| Test Type | Test Value | Test Results |
| 1 - Read Initial Value of Object |
0 |
Success |
| 2 - Set Object to Min. Value |
0 |
Success |
| 3 - Set Object to Max. Value |
0 |
Success |
| 4 - Attempt Write to Read-Only Object |
|
Skipped - Not read only |
| 5 - Attempt Read of Non-Accessible Object |
|
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
256 |
Success - did not write greater than Max |
| 7 - Attempt to Set Value < Min. |
-1 |
Success - did not write less than Min |
| 8 - Restore Object to Original Value |
0 |
Success |
Overall Test Case Results: Passed
Object Test Case TC-O-276
VDOT Implemented: Yes
| Std Par Ref |
5.8.7 |
| OID |
1.3.6.1.4.1.1206.4.2.3.7.7.0 |
| Object Name |
dmsIllumBrightnessValues |
| Syntax | Access | Status |
| OCTET STRING |
read-write |
optional |
| Test Type | Test Value | Test Results |
| 1 - Read Initial Value of Object |
10 05 14 00 00 01 F4 0A 29 01 F5 03 E8 0F 3D 03 E9 05 DC 14 52 05 DD 07 D0 19 66 07 D1 09 C4 1E 7B 09 C5 0B B8 23 8F 0B B9 0D AC 28 A4 0D AD 0F A0 2D 8B 0F A1 11 94 32 CD 11 95 13 88 3F 80 13 89 27 10 4C 33 27 11 3A 98 65 9A 3A 99 4E 20 7F 00 4E 21 75 ... |
Success |
| 2 - Set Object to Min. Value |
10 05 14 00 00 01 F4 0A 29 01 F5 03 E8 0F 3D 03 E9 05 DC 14 52 05 DD 07 D0 19 66 07 D1 09 C4 1E 7B 09 C5 0B B8 23 8F 0B B9 0D AC 28 A4 0D AD 0F A0 2D 8B 0F A1 11 94 32 CD 11 95 13 88 3F 80 13 89 27 10 4C 33 27 11 3A 98 65 9A 3A 99 4E 20 7F 00 4E 21 75 ... |
Success |
| 3 - Set Object to Max. Value |
10 05 14 00 00 01 F4 0A 29 01 F5 03 E8 0F 3D 03 E9 05 DC 14 52 05 DD 07 D0 19 66 07 D1 09 C4 1E 7B 09 C5 0B B8 23 8F 0B B9 0D AC 28 A4 0D AD 0F A0 2D 8B 0F A1 11 94 32 CD 11 95 13 88 3F 80 13 89 27 10 4C 33 27 11 3A 98 65 9A 3A 99 4E 20 7F 00 4E 21 75 ... |
Success |
| 4 - Attempt Write to Read-Only Object |
00 |
Skipped - Not read only |
| 5 - Attempt Read of Non-Accessible Object |
00 |
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
00 |
Skipped - no Minimum |
| 7 - Attempt to Set Value < Min. |
00 |
Skipped - no Minimum |
| 8 - Restore Object to Original Value |
10 05 14 00 00 01 F4 0A 29 01 F5 03 E8 0F 3D 03 E9 05 DC 14 52 05 DD 07 D0 19 66 07 D1 09 C4 1E 7B 09 C5 0B B8 23 8F 0B B9 0D AC 28 A4 0D AD 0F A0 2D 8B 0F A1 11 94 32 CD 11 95 13 88 3F 80 13 89 27 10 4C 33 27 11 3A 98 65 9A 3A 99 4E 20 7F 00 4E 21 75 ... |
Success |
Overall Test Case Results: Passed
Object Test Case TC-O-277
VDOT Implemented: Yes
| Std Par Ref |
5.8.8 |
| OID |
1.3.6.1.4.1.1206.4.2.3.7.8.0 |
| Object Name |
dmsIllumBrightnessValuesError |
| Syntax | Access | Status |
| INTEGER {enumeration} |
read-only |
optional |
| Test Type | Test Value | Test Results |
| 1 - Read Initial Value of Object |
2 (none) |
Success |
| 2 - Set Object to Min. Value |
2 (none) |
Success |
| 3 - Set Object to Max. Value |
2 (none) |
Success |
| 4 - Attempt Write to Read-Only Object |
|
Failed - NoSuchName |
| 5 - Attempt Read of Non-Accessible Object |
|
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
|
Skipped - not writable |
| 7 - Attempt to Set Value < Min. |
|
Skipped - not writable |
| 8 - Restore Object to Original Value |
|
Skipped - Not writable |
Overall Test Case Results: Passed
Object Test Case TC-O-278
VDOT Implemented: Yes
| Std Par Ref |
5.8.9 |
| OID |
1.3.6.1.4.1.1206.4.2.3.7.9.0 |
| Object Name |
dmsIllumLightOutputStatus |
| Syntax | Access | Status |
| INTEGER (0..65535) |
read-only |
optional |
| Test Type | Test Value | Test Results |
| 1 - Read Initial Value of Object |
0 |
Success |
| 2 - Set Object to Min. Value |
0 |
Success |
| 3 - Set Object to Max. Value |
0 |
Success |
| 4 - Attempt Write to Read-Only Object |
0 |
Failed - wrote to read only |
| 5 - Attempt Read of Non-Accessible Object |
|
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
|
Skipped - not writable |
| 7 - Attempt to Set Value < Min. |
|
Skipped - not writable |
| 8 - Restore Object to Original Value |
|
Skipped - Not writable |
Overall Test Case Results: Passed
Object Test Case TC-O-279
VDOT Implemented: Yes
| Std Par Ref |
5.9.1 |
| OID |
1.3.6.1.4.1.1206.4.2.3.8.1.0 |
| Object Name |
numActionTableEntries |
| Syntax | Access | Status |
| INTEGER (0..255) |
read-only |
optional |
| Test Type | Test Value | Test Results |
| 1 - Read Initial Value of Object |
64 |
Success |
| 2 - Set Object to Min. Value |
64 |
Success |
| 3 - Set Object to Max. Value |
64 |
Success |
| 4 - Attempt Write to Read-Only Object |
|
Failed - NoSuchName |
| 5 - Attempt Read of Non-Accessible Object |
|
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
|
Skipped - not writable |
| 7 - Attempt to Set Value < Min. |
|
Skipped - not writable |
| 8 - Restore Object to Original Value |
|
Skipped - Not writable |
Overall Test Case Results: Passed
Object Test Case TC-O-280
VDOT Implemented: Yes
| Std Par Ref |
5.9.2.1 |
| OID |
1.3.6.1.4.1.1206.4.2.3.8.2.1.1.1 |
| Object Name |
dmsActionIndex |
| Syntax | Access | Status |
| INTEGER (1..255) |
read-only |
optional |
| Test Type | Test Value | Test Results |
| 1 - Read Initial Value of Object |
1 |
Success |
| 2 - Set Object to Min. Value |
1 |
Success |
| 3 - Set Object to Max. Value |
1 |
Success |
| 4 - Attempt Write to Read-Only Object |
|
Failed - NoSuchName |
| 5 - Attempt Read of Non-Accessible Object |
|
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
|
Skipped - not writable |
| 7 - Attempt to Set Value < Min. |
|
Skipped - not writable |
| 8 - Restore Object to Original Value |
|
Skipped - Not writable |
Overall Test Case Results: Passed
Object Test Case TC-O-281
VDOT Implemented: Yes
| Std Par Ref |
5.9.2.2 |
| OID |
1.3.6.1.4.1.1206.4.2.3.8.2.1.2.1 |
| Object Name |
dmsActionMsgCode |
| Syntax | Access | Status |
| MessageIDCode |
read-write |
optional |
| Test Type | Test Value | Test Results |
| 1 - Read Initial Value of Object |
04 00 01 4B 6B |
Success |
| 2 - Set Object to Min. Value |
04 00 01 4B 6B |
Success |
| 3 - Set Object to Max. Value |
04 00 01 4B 6B |
Success |
| 4 - Attempt Write to Read-Only Object |
00 |
Skipped - Not read only |
| 5 - Attempt Read of Non-Accessible Object |
00 |
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
00 |
Skipped - no Minimum |
| 7 - Attempt to Set Value < Min. |
00 |
Skipped - no Minimum |
| 8 - Restore Object to Original Value |
04 00 01 4B 6B |
Success |
Overall Test Case Results: Passed
Object Test Case TC-O-282
VDOT Implemented: Yes
| Std Par Ref |
5.11.1.1 |
| OID |
1.3.6.1.4.1.1206.4.2.3.9.1.0 |
| Object Name |
statMultiFieldRows |
| Syntax | Access | Status |
| INTEGER (0..255) |
read-only |
optional |
| Test Type | Test Value | Test Results |
| 1 - Read Initial Value of Object |
0 |
Success |
| 2 - Set Object to Min. Value |
0 |
Success |
| 3 - Set Object to Max. Value |
0 |
Success |
| 4 - Attempt Write to Read-Only Object |
|
Failed - NoSuchName |
| 5 - Attempt Read of Non-Accessible Object |
|
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
|
Skipped - not writable |
| 7 - Attempt to Set Value < Min. |
|
Skipped - not writable |
| 8 - Restore Object to Original Value |
|
Skipped - Not writable |
Overall Test Case Results: Passed
Object Test Case TC-O-283
VDOT Implemented: Yes
| Std Par Ref |
5.11.1.3 |
| OID |
1.3.6.1.4.1.1206.4.2.3.9.3.0 |
| Object Name |
dmsCurrentSpeed |
| Syntax | Access | Status |
| INTEGER (0..255) |
read-only |
optional |
| Test Type | Test Value | Test Results |
| 1 - Read Initial Value of Object |
|
Failed - NoSuchName |
| 2 - Set Object to Min. Value |
|
Failed - NoSuchName |
| 3 - Set Object to Max. Value |
|
Failed - NoSuchName |
| 5 - Attempt Read of Non-Accessible Object |
|
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
|
Skipped - not writable |
| 7 - Attempt to Set Value < Min. |
|
Skipped - not writable |
| 8 - Restore Object to Original Value |
|
Skipped - not writable |
Overall Test Case Results: Passed
Object Test Case TC-O-284
VDOT Implemented: Yes
| Std Par Ref |
5.11.1.4 |
| OID |
1.3.6.1.4.1.1206.4.2.3.9.4.0 |
| Object Name |
dmsCurrentSpeedLimit |
| Syntax | Access | Status |
| INTEGER (0..255) |
read-write |
optional |
| Test Type | Test Value | Test Results |
| 1 - Read Initial Value of Object |
|
Failed - NoSuchName |
| 2 - Set Object to Min. Value |
|
Failed - NoSuchName |
| 3 - Set Object to Max. Value |
|
Failed - NoSuchName |
| 4 - Attempt Write to Read-Only Object |
|
Skipped - Not read only |
| 5 - Attempt Read of Non-Accessible Object |
|
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
256 |
Success - did not write greater than Max |
| 7 - Attempt to Set Value < Min. |
-1 |
Success - did not write less than Min |
Overall Test Case Results: Passed
Object Test Case TC-O-285
VDOT Implemented: Yes
| Std Par Ref |
5.11.1.5 |
| OID |
1.3.6.1.4.1.1206.4.2.3.9.5.0 |
| Object Name |
watchdogFailureCount |
| Syntax | Access | Status |
| Counter |
read-only |
optional |
| Test Type | Test Value | Test Results |
| 1 - Read Initial Value of Object |
27 |
Success |
| 2 - Set Object to Min. Value |
28 |
Success |
| 3 - Set Object to Max. Value |
29 |
Success |
| 4 - Attempt Write to Read-Only Object |
|
Failed - NoSuchName |
| 5 - Attempt Read of Non-Accessible Object |
|
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
|
Skipped - not writable |
| 7 - Attempt to Set Value < Min. |
|
Skipped - not writable |
| 8 - Restore Object to Original Value |
|
Skipped - Not writable |
Overall Test Case Results: Passed
Object Test Case TC-O-286
VDOT Implemented: Yes
| Std Par Ref |
5.11.1.6 |
| OID |
1.3.6.1.4.1.1206.4.2.3.9.6.0 |
| Object Name |
dmsStatDoorOpen |
| Syntax | Access | Status |
| INTEGER (0..255) |
read-only |
optional |
| Test Type | Test Value | Test Results |
| 1 - Read Initial Value of Object |
0 |
Success |
| 2 - Set Object to Min. Value |
0 |
Success |
| 3 - Set Object to Max. Value |
0 |
Success |
| 4 - Attempt Write to Read-Only Object |
|
Failed - NoSuchName |
| 5 - Attempt Read of Non-Accessible Object |
|
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
|
Skipped - not writable |
| 7 - Attempt to Set Value < Min. |
|
Skipped - not writable |
| 8 - Restore Object to Original Value |
|
Skipped - Not writable |
Overall Test Case Results: Passed
Object Test Case TC-O-287
VDOT Implemented: Yes
| Std Par Ref |
5.11.2.1.1 |
| OID |
1.3.6.1.4.1.1206.4.2.3.9.7.1.0 |
| Object Name |
shortErrorStatus |
| Syntax | Access | Status |
| INTEGER (0..65535) |
read-only |
optional |
| Test Type | Test Value | Test Results |
| 1 - Read Initial Value of Object |
2148 |
Success |
| 2 - Set Object to Min. Value |
2148 |
Success |
| 3 - Set Object to Max. Value |
2148 |
Success |
| 4 - Attempt Write to Read-Only Object |
|
Failed - NoSuchName |
| 5 - Attempt Read of Non-Accessible Object |
|
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
|
Skipped - not writable |
| 7 - Attempt to Set Value < Min. |
|
Skipped - not writable |
| 8 - Restore Object to Original Value |
|
Skipped - Not writable |
Overall Test Case Results: Passed
Object Test Case TC-O-288
VDOT Implemented: Yes
| Std Par Ref |
5.11.2.1.2 |
| OID |
1.3.6.1.4.1.1206.4.2.3.9.7.10.0 |
| Object Name |
controllerErrorStatus |
| Syntax | Access | Status |
| INTEGER (0..255) |
read-only |
optional |
| Test Type | Test Value | Test Results |
| 1 - Read Initial Value of Object |
0 |
Success |
| 2 - Set Object to Min. Value |
0 |
Success |
| 3 - Set Object to Max. Value |
0 |
Success |
| 4 - Attempt Write to Read-Only Object |
|
Failed - NoSuchName |
| 5 - Attempt Read of Non-Accessible Object |
|
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
|
Skipped - not writable |
| 7 - Attempt to Set Value < Min. |
|
Skipped - not writable |
| 8 - Restore Object to Original Value |
|
Skipped - Not writable |
Overall Test Case Results: Passed
Object Test Case TC-O-289
VDOT Implemented: Yes
| Std Par Ref |
5.11.2.2.1 |
| OID |
1.3.6.1.4.1.1206.4.2.3.9.7.11.0 |
| Object Name |
dmsPowerStatusMap |
| Syntax | Access | Status |
| OCTET STRING (SIZE (0..64)) |
read-only |
optional |
| Test Type | Test Value | Test Results |
| 1 - Read Initial Value of Object |
01 |
Success |
| 2 - Set Object to Min. Value |
01 |
Success |
| 3 - Set Object to Max. Value |
01 |
Success |
| 4 - Attempt Write to Read-Only Object |
00 |
Failed - NoSuchName |
| 5 - Attempt Read of Non-Accessible Object |
00 |
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
00 |
Skipped - not writable |
| 7 - Attempt to Set Value < Min. |
00 |
Skipped - not writable |
| 8 - Restore Object to Original Value |
00 |
Skipped - Not writable |
Overall Test Case Results: Passed
Object Test Case TC-O-290
VDOT Implemented: Yes
| Std Par Ref |
5.11.2.2.2 |
| OID |
1.3.6.1.4.1.1206.4.2.3.9.7.12.0 |
| Object Name |
dmsPowerNumRows |
| Syntax | Access | Status |
| INTEGER (0..512) |
read-only |
optional |
| Test Type | Test Value | Test Results |
| 1 - Read Initial Value of Object |
1 |
Success |
| 2 - Set Object to Min. Value |
1 |
Success |
| 3 - Set Object to Max. Value |
1 |
Success |
| 4 - Attempt Write to Read-Only Object |
|
Failed - NoSuchName |
| 5 - Attempt Read of Non-Accessible Object |
|
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
|
Skipped - not writable |
| 7 - Attempt to Set Value < Min. |
|
Skipped - not writable |
| 8 - Restore Object to Original Value |
|
Skipped - Not writable |
Overall Test Case Results: Passed
Object Test Case TC-O-291
VDOT Implemented: Yes
| Std Par Ref |
5.11.2.2.3.1 |
| OID |
1.3.6.1.4.1.1206.4.2.3.9.7.13.1.1.1 |
| Object Name |
dmsPowerIndex |
| Syntax | Access | Status |
| INTEGER (1..512) |
read-only |
optional |
| Test Type | Test Value | Test Results |
| 1 - Read Initial Value of Object |
1 |
Success |
| 2 - Set Object to Min. Value |
1 |
Success |
| 3 - Set Object to Max. Value |
1 |
Success |
| 4 - Attempt Write to Read-Only Object |
|
Failed - NoSuchName |
| 5 - Attempt Read of Non-Accessible Object |
|
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
|
Skipped - not writable |
| 7 - Attempt to Set Value < Min. |
|
Skipped - not writable |
| 8 - Restore Object to Original Value |
|
Skipped - Not writable |
Overall Test Case Results: Passed
Object Test Case TC-O-292
VDOT Implemented: Yes
| Std Par Ref |
5.11.2.2.3.2 |
| OID |
1.3.6.1.4.1.1206.4.2.3.9.7.13.1.2.1 |
| Object Name |
dmsPowerDescription |
| Syntax | Access | Status |
| DisplayString |
read-only |
optional |
| Test Type | Test Value | Test Results |
| 1 - Read Initial Value of Object |
4C 45 44 20 50 6F 77 65 72 20 73 75 70 70 6C 79 00 00 00 00 |
Success |
| 2 - Set Object to Min. Value |
4C 45 44 20 50 6F 77 65 72 20 73 75 70 70 6C 79 00 00 00 00 |
Success |
| 3 - Set Object to Max. Value |
4C 45 44 20 50 6F 77 65 72 20 73 75 70 70 6C 79 00 00 00 00 |
Success |
| 4 - Attempt Write to Read-Only Object |
00 |
Failed - NoSuchName |
| 5 - Attempt Read of Non-Accessible Object |
00 |
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
00 |
Skipped - not writable |
| 7 - Attempt to Set Value < Min. |
00 |
Skipped - not writable |
| 8 - Restore Object to Original Value |
00 |
Skipped - Not writable |
Overall Test Case Results: Passed
Object Test Case TC-O-293
VDOT Implemented: Yes
| Std Par Ref |
5.11.2.2.3.3 |
| OID |
1.3.6.1.4.1.1206.4.2.3.9.7.13.1.3.1 |
| Object Name |
dmsPowerMfrStatus |
| Syntax | Access | Status |
| DisplayString (SIZE (0..64)) |
read-only |
optional |
| Test Type | Test Value | Test Results |
| 1 - Read Initial Value of Object |
|
Success |
| 2 - Set Object to Min. Value |
|
Success |
| 3 - Set Object to Max. Value |
|
Success |
| 4 - Attempt Write to Read-Only Object |
00 |
Failed - NoSuchName |
| 5 - Attempt Read of Non-Accessible Object |
00 |
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
00 |
Skipped - not writable |
| 7 - Attempt to Set Value < Min. |
00 |
Skipped - not writable |
| 8 - Restore Object to Original Value |
00 |
Skipped - Not writable |
Overall Test Case Results: Passed
Object Test Case TC-O-294
VDOT Implemented: Yes
| Std Par Ref |
5.11.2.2.3.4 |
| OID |
1.3.6.1.4.1.1206.4.2.3.9.7.13.1.4.1 |
| Object Name |
dmsPowerStatus |
| Syntax | Access | Status |
| INTEGER {enumeration} |
read-only |
optional |
| Test Type | Test Value | Test Results |
| 1 - Read Initial Value of Object |
3 (powerFail) |
Success |
| 2 - Set Object to Min. Value |
3 (powerFail) |
Success |
| 3 - Set Object to Max. Value |
3 (powerFail) |
Success |
| 4 - Attempt Write to Read-Only Object |
|
Failed - NoSuchName |
| 5 - Attempt Read of Non-Accessible Object |
|
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
|
Skipped - not writable |
| 7 - Attempt to Set Value < Min. |
|
Skipped - not writable |
| 8 - Restore Object to Original Value |
|
Skipped - Not writable |
Overall Test Case Results: Passed
Object Test Case TC-O-295
VDOT Implemented: Yes
| Std Par Ref |
5.11.2.2.3.5 |
| OID |
1.3.6.1.4.1.1206.4.2.3.9.7.15.0 |
| Object Name |
dmsPowerType |
| Syntax | Access | Status |
| INTEGER {enumeration} |
read-only |
optional |
| Test Type | Test Value | Test Results |
| 1 - Read Initial Value of Object |
|
Failed - NoSuchName |
| 2 - Set Object to Min. Value |
|
Failed - NoSuchName |
| 3 - Set Object to Max. Value |
|
Failed - NoSuchName |
| 5 - Attempt Read of Non-Accessible Object |
|
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
|
Skipped - not writable |
| 7 - Attempt to Set Value < Min. |
|
Skipped - not writable |
| 8 - Restore Object to Original Value |
|
Skipped - Not writable |
Overall Test Case Results: Passed
Object Test Case TC-O-296
VDOT Implemented: Yes
| Std Par Ref |
5.11.2.3.1 |
| OID |
1.3.6.1.4.1.1206.4.2.3.9.7.8.0 |
| Object Name |
fanFailures |
| Syntax | Access | Status |
| OCTET STRING (SIZE (0..4)) |
read-only |
optional |
| Test Type | Test Value | Test Results |
| 1 - Read Initial Value of Object |
00 |
Success |
| 2 - Set Object to Min. Value |
00 |
Success |
| 3 - Set Object to Max. Value |
00 |
Success |
| 4 - Attempt Write to Read-Only Object |
00 |
Failed - NoSuchName |
| 5 - Attempt Read of Non-Accessible Object |
00 |
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
00 |
Skipped - not writable |
| 7 - Attempt to Set Value < Min. |
00 |
Skipped - not writable |
| 8 - Restore Object to Original Value |
00 |
Skipped - Not writable |
Overall Test Case Results: Passed
Object Test Case TC-O-297
VDOT Implemented: Yes
| Std Par Ref |
5.11.2.3.2 |
| OID |
1.3.6.1.4.1.1206.4.2.3.9.7.9.0 |
| Object Name |
fanTestActivation |
| Syntax | Access | Status |
| INTEGER {enumeration} |
read-write |
optional |
| Test Type | Test Value | Test Results |
| 1 - Read Initial Value of Object |
2 (noTest) |
Success |
| 2 - Set Object to Min. Value |
2 (noTest) |
Success |
| 3 - Set Object to Max. Value |
2 (noTest) |
Success |
| 4 - Attempt Write to Read-Only Object |
|
Skipped - Not read only |
| 5 - Attempt Read of Non-Accessible Object |
|
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
|
Skipped - no Minimum |
| 7 - Attempt to Set Value < Min. |
|
Skipped - no Minimum |
| 8 - Restore Object to Original Value |
2 (noTest) |
Success |
Overall Test Case Results: Passed
Object Test Case TC-O-298
VDOT Implemented: Yes
| Std Par Ref |
5.11.2.3.3 |
| OID |
1.3.6.1.4.1.1206.4.2.3.9.7.14.0 |
| Object Name |
dmsClimateCtrlStatusMap |
| Syntax | Access | Status |
| OCTET STRING (SIZE (0..64)) |
read-only |
optional |
| Test Type | Test Value | Test Results |
| 1 - Read Initial Value of Object |
00 |
Success |
| 2 - Set Object to Min. Value |
00 |
Success |
| 3 - Set Object to Max. Value |
00 |
Success |
| 4 - Attempt Write to Read-Only Object |
00 |
Failed - NoSuchName |
| 5 - Attempt Read of Non-Accessible Object |
00 |
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
00 |
Skipped - not writable |
| 7 - Attempt to Set Value < Min. |
00 |
Skipped - not writable |
| 8 - Restore Object to Original Value |
00 |
Skipped - Not writable |
Overall Test Case Results: Passed
Object Test Case TC-O-299
VDOT Implemented: Yes
| Std Par Ref |
5.11.2.3.4 |
| OID |
1.3.6.1.4.1.1206.4.2.3.9.7.16.0 |
| Object Name |
dmsClimateCtrlNumRows |
| Syntax | Access | Status |
| INTEGER (0..512) |
read-only |
optional |
| Test Type | Test Value | Test Results |
| 1 - Read Initial Value of Object |
0 |
Success |
| 2 - Set Object to Min. Value |
0 |
Success |
| 3 - Set Object to Max. Value |
0 |
Success |
| 4 - Attempt Write to Read-Only Object |
|
Failed - NoSuchName |
| 5 - Attempt Read of Non-Accessible Object |
|
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
|
Skipped - not writable |
| 7 - Attempt to Set Value < Min. |
|
Skipped - not writable |
| 8 - Restore Object to Original Value |
|
Skipped - Not writable |
Overall Test Case Results: Passed
Object Test Case TC-O-300
VDOT Implemented: Yes
| Std Par Ref |
5.11.2.3.5.1 |
| OID |
1.3.6.1.4.1.1206.4.2.3.9.7.17.1.1.1 |
| Object Name |
dmsClimateCtrlIndex |
| Syntax | Access | Status |
| INTEGER (1..512) |
read-only |
optional |
| Test Type | Test Value | Test Results |
| 1 - Read Initial Value of Object |
|
Failed - GenErr |
| 2 - Set Object to Min. Value |
|
Failed - GenErr |
| 3 - Set Object to Max. Value |
|
Failed - GenErr |
| 5 - Attempt Read of Non-Accessible Object |
|
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
|
Skipped - not writable |
| 7 - Attempt to Set Value < Min. |
|
Skipped - not writable |
| 8 - Restore Object to Original Value |
|
Skipped - Not writable |
Overall Test Case Results: Passed
Object Test Case TC-O-301
VDOT Implemented: Yes
| Std Par Ref |
5.11.2.3.5.2 |
| OID |
1.3.6.1.4.1.1206.4.2.3.9.7.17.1.2.1 |
| Object Name |
dmsClimateCtrlDescription |
| Syntax | Access | Status |
| DisplayString |
read-only |
optional |
| Test Type | Test Value | Test Results |
| 1 - Read Initial Value of Object |
00 |
Failed - GenErr |
| 2 - Set Object to Min. Value |
00 |
Failed - GenErr |
| 3 - Set Object to Max. Value |
00 |
Failed - GenErr |
| 4 - Attempt Write to Read-Only Object |
00 |
Failed - GenErr |
| 5 - Attempt Read of Non-Accessible Object |
00 |
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
00 |
Skipped - not writable |
| 7 - Attempt to Set Value < Min. |
00 |
Skipped - not writable |
| 8 - Restore Object to Original Value |
00 |
Skipped - Not writable |
Overall Test Case Results: Passed
Object Test Case TC-O-302
VDOT Implemented: Yes
| Std Par Ref |
5.11.2.3.5.3 |
| OID |
1.3.6.1.4.1.1206.4.2.3.9.7.17.1.3.1 |
| Object Name |
dmsClimateCtrlMfrStatus |
| Syntax | Access | Status |
| DisplayString (SIZE (0..64)) |
read-only |
optional |
| Test Type | Test Value | Test Results |
| 1 - Read Initial Value of Object |
00 |
Failed - GenErr |
| 2 - Set Object to Min. Value |
00 |
Failed - GenErr |
| 3 - Set Object to Max. Value |
00 |
Failed - GenErr |
| 4 - Attempt Write to Read-Only Object |
00 |
Failed - GenErr |
| 5 - Attempt Read of Non-Accessible Object |
00 |
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
00 |
Skipped - not writable |
| 7 - Attempt to Set Value < Min. |
00 |
Skipped - not writable |
| 8 - Restore Object to Original Value |
00 |
Skipped - Not writable |
Overall Test Case Results: Passed
Object Test Case TC-O-303
VDOT Implemented: Yes
| Std Par Ref |
5.11.2.3.5.4 |
| OID |
1.3.6.1.4.1.1206.4.2.3.9.7.17.1.4.1 |
| Object Name |
dmsClimateCtrlErrorStatus |
| Syntax | Access | Status |
| INTEGER {enumeration} |
read-only |
optional |
| Test Type | Test Value | Test Results |
| 1 - Read Initial Value of Object |
|
Failed - GenErr |
| 2 - Set Object to Min. Value |
|
Failed - GenErr |
| 3 - Set Object to Max. Value |
|
Failed - GenErr |
| 5 - Attempt Read of Non-Accessible Object |
|
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
|
Skipped - not writable |
| 7 - Attempt to Set Value < Min. |
|
Skipped - not writable |
| 8 - Restore Object to Original Value |
|
Skipped - Not writable |
Overall Test Case Results: Passed
Object Test Case TC-O-304
VDOT Implemented: Yes
| Std Par Ref |
5.11.2.3.5.5 |
| OID |
1.3.6.1.4.1.1206.4.2.3.9.7.17.1.5.1 |
| Object Name |
dmsClimateCtrlOnStatus |
| Syntax | Access | Status |
| INTEGER (0..1) |
read-only |
optional |
| Test Type | Test Value | Test Results |
| 1 - Read Initial Value of Object |
|
Failed - GenErr |
| 2 - Set Object to Min. Value |
|
Failed - GenErr |
| 3 - Set Object to Max. Value |
|
Failed - GenErr |
| 5 - Attempt Read of Non-Accessible Object |
|
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
|
Skipped - not writable |
| 7 - Attempt to Set Value < Min. |
|
Skipped - not writable |
| 8 - Restore Object to Original Value |
|
Skipped - Not writable |
Overall Test Case Results: Passed
Object Test Case TC-O-305
VDOT Implemented: Yes
| Std Par Ref |
5.11.2.3.5.6 |
| OID |
1.3.6.1.4.1.1206.4.2.3.9.7.17.1.6.1 |
| Object Name |
dmsClimateCtrlTestActivation |
| Syntax | Access | Status |
| INTEGER {enumeration} |
read-write |
optional |
| Test Type | Test Value | Test Results |
| 1 - Read Initial Value of Object |
|
Failed - GenErr |
| 2 - Set Object to Min. Value |
|
Failed - GenErr |
| 3 - Set Object to Max. Value |
|
Failed - GenErr |
| 4 - Attempt Write to Read-Only Object |
|
Skipped - Not read only |
| 5 - Attempt Read of Non-Accessible Object |
|
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
|
Skipped - no Minimum |
| 7 - Attempt to Set Value < Min. |
|
Skipped - no Minimum |
Overall Test Case Results: Passed
Object Test Case TC-O-306
VDOT Implemented: Yes
| Std Par Ref |
5.11.2.3.5.7 |
| OID |
1.3.6.1.4.1.1206.4.2.3.9.7.17.1.7.1 |
| Object Name |
dmsClimateCtrlAbortReason |
| Syntax | Access | Status |
| DisplayString (SIZE (0..64)) |
write-only |
optional |
| Test Type | Test Value | Test Results |
| 1 - Read Initial Value of Object |
00 |
Failed - GenErr |
| 2 - Set Object to Min. Value |
00 |
Failed - GenErr |
| 3 - Set Object to Max. Value |
00 |
Failed - GenErr |
| 4 - Attempt Write to Read-Only Object |
00 |
Skipped - Not read only |
| 5 - Attempt Read of Non-Accessible Object |
00 |
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
1 |
Success - did not write greater than Max |
| 7 - Attempt to Set Value < Min. |
-1 |
Success - did not write less than Min |
| 8 - Restore Object to Original Value |
00 |
Failed - GenErr |
Overall Test Case Results: Passed
Object Test Case TC-O-307
VDOT Implemented: Yes
| Std Par Ref |
5.11.2.4.1 |
| OID |
1.3.6.1.4.1.1206.4.2.3.9.7.2.0 |
| Object Name |
pixelFailureTableNumRows |
| Syntax | Access | Status |
| INTEGER (0..65535) |
read-only |
optional |
| Test Type | Test Value | Test Results |
| 1 - Read Initial Value of Object |
1620 |
Success |
| 2 - Set Object to Min. Value |
0 |
Success |
| 3 - Set Object to Max. Value |
0 |
Success |
| 4 - Attempt Write to Read-Only Object |
|
Failed - NoSuchName |
| 5 - Attempt Read of Non-Accessible Object |
|
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
|
Skipped - not writable |
| 7 - Attempt to Set Value < Min. |
|
Skipped - not writable |
| 8 - Restore Object to Original Value |
|
Skipped - Not writable |
Overall Test Case Results: Passed
Object Test Case TC-O-308
VDOT Implemented: Yes
| Std Par Ref |
5.11.2.4.2.1 |
| OID |
1.3.6.1.4.1.1206.4.2.3.9.7.3.1.1.1.1 |
| Object Name |
pixelFailureDetectionType |
| Syntax | Access | Status |
| INTEGER {enumeration} |
read-only |
optional |
| Test Type | Test Value | Test Results |
| 1 - Read Initial Value of Object |
2 (pixelTest) |
Success |
| 2 - Set Object to Min. Value |
0 |
Success |
| 3 - Set Object to Max. Value |
0 |
Success |
| 4 - Attempt Write to Read-Only Object |
|
Failed - NoSuchName |
| 5 - Attempt Read of Non-Accessible Object |
|
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
|
Skipped - not writable |
| 7 - Attempt to Set Value < Min. |
|
Skipped - not writable |
| 8 - Restore Object to Original Value |
|
Skipped - Not writable |
Overall Test Case Results: Passed
Object Test Case TC-O-309
VDOT Implemented: Yes
| Std Par Ref | 5.11.2.4.2.2 |
| OID | 1.3.6.1.4.1.1206.4.2.3.9.7.3.1.2.1.1 |
| Object Name | pixelFailureIndex |
| Syntax | Access | Status |
| INTEGER (1..65535) | read-only | optional |
| Test Type | Test Value | Test Results |
| 1 - Read Initial Value of Object | 1 | Success |
| 2 - Set Object to Min. Value | 1 | Success |
| 3 - Set Object to Max. Value | 1 | Success |
| 4 - Attempt Write to Read-Only Object | |
Failed - NoSuchName |
| 5 - Attempt Read of Non-Accessible Object | |
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. | |
Skipped - not writable |
| 7 - Attempt to Set Value < Min. | |
Skipped - not writable |
| 8 - Restore Object to Original Value | |
Skipped - Not writable |
Overall Test Case Results: Passed
Object Test Case TC-O-310
VDOT Implemented: Yes
| Std Par Ref | 5.11.2.4.2.3 |
| OID | 1.3.6.1.4.1.1206.4.2.3.9.7.3.1.3.1.1 |
| Object Name | pixelFailureXLocation |
| Syntax | Access | Status |
| INTEGER (1..65535) | read-only | optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object | 1 | Success |
| 2 - Set Object to Min. Value | 0 | Success |
| 3 - Set Object to Max. Value | 0 | Success |
| 4 - Attempt Write to Read-Only Object | |
Failed - NoSuchName |
| 5 - Attempt Read of Non-Accessible Object | |
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. | |
Skipped - not writable |
| 7 - Attempt to Set Value < Min. | |
Skipped - not writable |
| 8 - Restore Object to Original Value | |
Skipped - Not writable |
Overall Test Case Results: Passed
Object Test Case TC-O-311
VDOT Implemented: Yes
| Std Par Ref | 5.11.2.4.2.4 |
| OID | 1.3.6.1.4.1.1206.4.2.3.9.7.3.1.4.1.1 |
| Object Name | pixelFailureYLocation |
| Syntax | Access | Status |
| INTEGER (1..65535) | read-only | optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object | 1 | Success |
| 2 - Set Object to Min. Value | 0 | Success |
| 3 - Set Object to Max. Value | 0 | Success |
| 4 - Attempt Write to Read-Only Object | |
Failed - NoSuchName |
| 5 - Attempt Read of Non-Accessible Object | |
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. | |
Skipped - not writable |
| 7 - Attempt to Set Value < Min. | |
Skipped - not writable |
| 8 - Restore Object to Original Value | |
Skipped - Not writable |
Overall Test Case Results: Passed
Object Test Case TC-O-312
VDOT Implemented: Yes
| Std Par Ref | 5.11.2.4.2.5 |
| OID | 1.3.6.1.4.1.1206.4.2.3.9.7.3.1.5.1.1 |
| Object Name | pixelFailureStatus |
| Syntax | Access | Status |
| INTEGER (0..255) | read-only | optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object | 5 | Success |
| 2 - Set Object to Min. Value | 0 | Success |
| 3 - Set Object to Max. Value | 0 | Success |
| 4 - Attempt Write to Read-Only Object | |
Failed - NoSuchName |
| 5 - Attempt Read of Non-Accessible Object | |
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. | |
Skipped - not writable |
| 7 - Attempt to Set Value < Min. | |
Skipped - not writable |
| 8 - Restore Object to Original Value | |
Skipped - Not writable |
Overall Test Case Results: Passed
Object Test Case TC-O-313
VDOT Implemented: Yes
| Std Par Ref | 5.11.2.4.3 |
| OID | 1.3.6.1.4.1.1206.4.2.3.9.7.4.0 |
| Object Name | pixelTestActivation |
| Syntax | Access | Status |
| INTEGER {enumeration} | read-write | optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object | 2 (noTest) | Success |
| 2 - Set Object to Min. Value | 2 (noTest) | Success |
| 3 - Set Object to Max. Value | 2 (noTest) | Success |
| 4 - Attempt Write to Read-Only Object | |
Skipped - Not read only |
| 5 - Attempt Read of Non-Accessible Object | |
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. | |
Skipped - no Minimum |
| 7 - Attempt to Set Value < Min. | |
Skipped - no Minimum |
| 8 - Restore Object to Original Value | 2 (noTest) | Success |
Overall Test Case Results: Passed
Object Test Case TC-O-314
VDOT Implemented: Yes
| Std Par Ref | 5.11.2.4.4.2 |
| OID | 1.3.6.1.4.1.1206.4.2.3.9.7.18.1.2.1 |
| Object Name | dmsPixelStatus |
| Syntax | Access | Status |
| OCTET STRING (SIZE(1..400)) | read-only | optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object | FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF ... | Success |
| 2 - Set Object to Min. Value | 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 ... | Success |
| 3 - Set Object to Max. Value | 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 ... | Success |
| 4 - Attempt Write to Read-Only Object |
00 | Failed - NoSuchName |
| 5 - Attempt Read of Non-Accessible Object |
00 | Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
00 | Skipped - not writable |
| 7 - Attempt to Set Value < Min. |
00 | Skipped - not writable |
| 8 - Restore Object to Original Value |
00 | Skipped - Not writable |
Overall Test Case Results: Passed
Object Test Case TC-O-315
VDOT Implemented: Yes
| Std Par Ref | 5.11.2.4.5 |
| OID | 1.3.6.1.4.1.1206.4.2.3.9.7.18.1.3.1 |
| Object Name | dmsPixelFailureTestRows |
| Syntax | Access | Status |
| INTEGER (0..65535) | read-only | optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object | |
Failed - NoSuchName |
| 2 - Set Object to Min. Value | |
Failed - NoSuchName |
| 3 - Set Object to Max. Value | |
Failed - NoSuchName |
| 5 - Attempt Read of Non-Accessible Object | |
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. | |
Skipped - not writable |
| 7 - Attempt to Set Value < Min. | |
Skipped - not writable |
| 8 - Restore Object to Original Value | |
Skipped - Not writable |
Overall Test Case Results: Passed
Object Test Case TC-O-316
VDOT Implemented: Yes
| Std Par Ref | 5.11.2.4.6 |
| OID | 1.3.6.1.4.1.1206.4.2.3.9.7.18.1.4.1 |
| Object Name | dmsPixelFailureMessageRows |
| Syntax | Access | Status |
| INTEGER (0..65535) | read-only | optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object | |
Failed - NoSuchName |
| 2 - Set Object to Min. Value | |
Failed - NoSuchName |
| 3 - Set Object to Max. Value | |
Failed - NoSuchName |
| 5 - Attempt Read of Non-Accessible Object | |
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. | |
Skipped - not writable |
| 7 - Attempt to Set Value < Min. | |
Skipped - not writable |
| 8 - Restore Object to Original Value | |
Skipped - Not writable |
Overall Test Case Results: Passed
Object Test Case TC-O-317
VDOT Implemented: Yes
| Std Par Ref | 5.11.2.5.1 |
| OID | 1.3.6.1.4.1.1206.4.2.3.9.7.5.0 |
| Object Name | lampFailureStuckOn |
| Syntax | Access | Status |
| OCTET STRING (SIZE (0..255)) | read-only | optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object |
00 | Failed - NoSuchName |
| 2 - Set Object to Min. Value |
00 | Failed - NoSuchName |
| 3 - Set Object to Max. Value |
00 | Failed - NoSuchName |
| 4 - Attempt Write to Read-Only Object |
00 | Failed - NoSuchName |
| 5 - Attempt Read of Non-Accessible Object |
00 | Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
00 | Skipped - not writable |
| 7 - Attempt to Set Value < Min. |
00 | Skipped - not writable |
| 8 - Restore Object to Original Value |
00 | Skipped - Not writable |
Overall Test Case Results: Passed
Object Test Case TC-O-318
VDOT Implemented: Yes
| Std Par Ref | 5.11.2.5.2 |
| OID | 1.3.6.1.4.1.1206.4.2.3.9.7.6.0 |
| Object Name | lampFailureStuckOff |
| Syntax | Access | Status |
| OCTET STRING (SIZE (0..255)) | read-only | optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object |
00 | Failed - NoSuchName |
| 2 - Set Object to Min. Value |
00 | Failed - NoSuchName |
| 3 - Set Object to Max. Value |
00 | Failed - NoSuchName |
| 4 - Attempt Write to Read-Only Object |
00 | Failed - NoSuchName |
| 5 - Attempt Read of Non-Accessible Object |
00 | Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
00 | Skipped - not writable |
| 7 - Attempt to Set Value < Min. |
00 | Skipped - not writable |
| 8 - Restore Object to Original Value |
00 | Skipped - Not writable |
Overall Test Case Results: Passed
Object Test Case TC-O-319
VDOT Implemented: Yes
| Std Par Ref | 5.11.2.5.3 |
| OID | 1.3.6.1.4.1.1206.4.2.3.9.7.7.0 |
| Object Name | lampTestActivation |
| Syntax | Access | Status |
| INTEGER {enumeration} | read-write | optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object | |
Failed - NoSuchName |
| 2 - Set Object to Min. Value | |
Failed - NoSuchName |
| 3 - Set Object to Max. Value | |
Failed - NoSuchName |
| 4 - Attempt Write to Read-Only Object | |
Skipped - Not read only |
| 5 - Attempt Read of Non-Accessible Object | |
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. | |
Skipped - no Minimum |
| 7 - Attempt to Set Value < Min. | |
Skipped - no Minimum |
Overall Test Case Results: Passed
Object Test Case TC-O-320
VDOT Implemented: Yes
| Std Par Ref | 5.11.2.5.4 |
| OID | 1.3.6.1.4.1.1206.4.2.3.9.7.23.0 |
| Object Name | dmsLampNumRows |
| Syntax | Access | Status |
| INTEGER (0..2040) | read-only | optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object | |
Failed - NoSuchName |
| 2 - Set Object to Min. Value | |
Failed - NoSuchName |
| 3 - Set Object to Max. Value | |
Failed - NoSuchName |
| 5 - Attempt Read of Non-Accessible Object | |
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. | |
Skipped - not writable |
| 7 - Attempt to Set Value < Min. | |
Skipped - not writable |
| 8 - Restore Object to Original Value | |
Skipped - Not writable |
Overall Test Case Results: Passed
Object Test Case TC-O-321
VDOT Implemented: Yes
| Std Par Ref | 5.11.2.5.5.1 |
| OID | 1.3.6.1.4.1.1206.4.2.3.9.7.24.1.1.1 |
| Object Name | dmsLampIndex |
| Syntax | Access | Status |
| INTEGER (1..2040) | read-only | optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object | |
Failed - NoSuchName |
| 2 - Set Object to Min. Value | |
Failed - NoSuchName |
| 3 - Set Object to Max. Value | |
Failed - NoSuchName |
| 5 - Attempt Read of Non-Accessible Object | |
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. | |
Skipped - not writable |
| 7 - Attempt to Set Value < Min. | |
Skipped - not writable |
| 8 - Restore Object to Original Value | |
Skipped - Not writable |
Overall Test Case Results: Passed
Object Test Case TC-O-322
VDOT Implemented: Yes
| Std Par Ref | 5.11.2.5.5.2 |
| OID | 1.3.6.1.4.1.1206.4.2.3.9.7.24.1.2.1 |
| Object Name | dmsLampDescription |
| Syntax | Access | Status |
| DisplayString | read-only | optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object |
00 | Failed - NoSuchName |
| 2 - Set Object to Min. Value |
00 | Failed - NoSuchName |
| 3 - Set Object to Max. Value |
00 | Failed - NoSuchName |
| 4 - Attempt Write to Read-Only Object |
00 | Failed - NoSuchName |
| 5 - Attempt Read of Non-Accessible Object |
00 | Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
00 | Skipped - not writable |
| 7 - Attempt to Set Value < Min. |
00 | Skipped - not writable |
| 8 - Restore Object to Original Value |
00 | Skipped - Not writable |
Overall Test Case Results: Passed
Object Test Case TC-O-323
VDOT Implemented: Yes
| Std Par Ref | 5.11.2.5.5.3 |
| OID | 1.3.6.1.4.1.1206.4.2.3.9.7.24.1.3.1 |
| Object Name | dmsLampMfrStatus |
| Syntax | Access | Status |
| DisplayString (SIZE (0..64)) | Read-only | optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object |
00 | Failed - NoSuchName |
| 2 - Set Object to Min. Value |
00 | Failed - NoSuchName |
| 3 - Set Object to Max. Value |
00 | Failed - NoSuchName |
| 4 - Attempt Write to Read-Only Object |
00 | Failed - NoSuchName |
| 5 - Attempt Read of Non-Accessible Object |
00 | Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
00 | Skipped - not writable |
| 7 - Attempt to Set Value < Min. |
00 | Skipped - not writable |
| 8 - Restore Object to Original Value |
00 | Skipped - Not writable |
Overall Test Case Results: Passed
Object Test Case TC-O-324
VDOT Implemented: Yes
| Std Par Ref | 5.11.2.5.5.4 |
| OID | 1.3.6.1.4.1.1206.4.2.3.9.7.24.1.4.1 |
| Object Name | dmsLampStatus |
| Syntax | Access | Status |
| INTEGER {enumeration} | read-only | optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object | |
Failed - NoSuchName |
| 2 - Set Object to Min. Value | |
Failed - NoSuchName |
| 3 - Set Object to Max. Value | |
Failed - NoSuchName |
| 5 - Attempt Read of Non-Accessible Object | |
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. | |
Skipped - not writable |
| 7 - Attempt to Set Value < Min. | |
Skipped - not writable |
| 8 - Restore Object to Original Value | |
Skipped - Not writable |
Overall Test Case Results: Passed
Object Test Case TC-O-325
VDOT Implemented: Yes
| Std Par Ref | 5.11.2.5.5.5 |
| OID | 1.3.6.1.4.1.1206.4.2.3.9.7.24.1.5.1 |
| Object Name | dmsLampPixelTop |
| Syntax | Access | Status |
| INTEGER (1..65535) | read-only | optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object | |
Failed - NoSuchName |
| 2 - Set Object to Min. Value | |
Failed - NoSuchName |
| 3 - Set Object to Max. Value | |
Failed - NoSuchName |
| 5 - Attempt Read of Non-Accessible Object | |
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. | |
Skipped - not writable |
| 7 - Attempt to Set Value < Min. | |
Skipped - not writable |
| 8 - Restore Object to Original Value | |
Skipped - Not writable |
Overall Test Case Results: Passed
Object Test Case TC-O-326
VDOT Implemented: Yes
| Std Par Ref | 5.11.2.5.5.6 |
| OID | 1.3.6.1.4.1.1206.4.2.3.9.7.24.1.6.1 |
| Object Name | dmsLampPixelLeft |
| Syntax | Access | Status |
| INTEGER (1..65535) | read-only | optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object | |
Failed - NoSuchName |
| 2 - Set Object to Min. Value | |
Failed - NoSuchName |
| 3 - Set Object to Max. Value | |
Failed - NoSuchName |
| 5 - Attempt Read of Non-Accessible Object | |
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. | |
Skipped - not writable |
| 7 - Attempt to Set Value < Min. | |
Skipped - not writable |
| 8 - Restore Object to Original Value | |
Skipped - Not writable |
Overall Test Case Results: Passed
Object Test Case TC-O-327
VDOT Implemented: Yes
| Std Par Ref | 5.11.2.5.5.7 |
| OID | 1.3.6.1.4.1.1206.4.2.3.9.7.24.1.7.1 |
| Object Name | dmsLampPixelBottom |
| Syntax | Access | Status |
| INTEGER (1..65535) | read-only | optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object | |
Failed - NoSuchName |
| 2 - Set Object to Min. Value | |
Failed - NoSuchName |
| 3 - Set Object to Max. Value | |
Failed - NoSuchName |
| 5 - Attempt Read of Non-Accessible Object | |
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. | |
Skipped - not writable |
| 7 - Attempt to Set Value < Min. | |
Skipped - not writable |
| 8 - Restore Object to Original Value | |
Skipped - Not writable |
Overall Test Case Results: Passed
Object Test Case TC-O-328
VDOT Implemented: Yes
| Std Par Ref | 5.11.2.5.5.8 |
| OID | 1.3.6.1.4.1.1206.4.2.3.9.7.24.1.8.1 |
| Object Name | dmsLampPixelRight |
| Syntax | Access | Status |
| INTEGER (1..65535) | read-only | optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object | |
Failed - NoSuchName |
| 2 - Set Object to Min. Value | |
Failed - NoSuchName |
| 3 - Set Object to Max. Value | |
Failed - NoSuchName |
| 5 - Attempt Read of Non-Accessible Object | |
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. | |
Skipped - not writable |
| 7 - Attempt to Set Value < Min. | |
Skipped - not writable |
| 8 - Restore Object to Original Value | |
Skipped - Not writable |
Overall Test Case Results: Passed
Object Test Case TC-O-329
VDOT Implemented: Yes
| Std Par Ref | 5.11.2.6.1 |
| OID | 1.3.6.1.4.1.1206.4.2.3.9.7.25.0 |
| Object Name | dmsDrumStatusMap |
| Syntax | Access | Status |
| OCTET STRING (SIZE (0..2)) | read-only | optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object |
00 | Failed - NoSuchName |
| 2 - Set Object to Min. Value |
00 | Failed - NoSuchName |
| 3 - Set Object to Max. Value |
00 | Failed - NoSuchName |
| 4 - Attempt Write to Read-Only Object |
00 | Failed - NoSuchName |
| 5 - Attempt Read of Non-Accessible Object |
00 | Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
00 | Skipped - not writable |
| 7 - Attempt to Set Value < Min. |
00 | Skipped - not writable |
| 8 - Restore Object to Original Value |
00 | Skipped - Not writable |
Overall Test Case Results: Passed
Object Test Case TC-O-330
VDOT Implemented: Yes
| Std Par Ref | 5.11.2.6.2 |
| OID | 1.3.6.1.4.1.1206.4.2.3.9.7.26.0 |
| Object Name | dmsDrumNumRows |
| Syntax | Access | Status |
| INTEGER (0..16) | read-only | optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object | |
Failed - NoSuchName |
| 2 - Set Object to Min. Value | |
Failed - NoSuchName |
| 3 - Set Object to Max. Value | |
Failed - NoSuchName |
| 5 - Attempt Read of Non-Accessible Object | |
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. | |
Skipped - not writable |
| 7 - Attempt to Set Value < Min. | |
Skipped - not writable |
| 8 - Restore Object to Original Value | |
Skipped - Not writable |
Overall Test Case Results: Passed
Object Test Case TC-O-331
VDOT Implemented: Yes
| Std Par Ref | 5.11.2.6.3.1 |
| OID | 1.3.6.1.4.1.1206.4.2.3.9.7.27.1.1.1 |
| Object Name | dmsDrumIndex |
| Syntax | Access | Status |
| INTEGER (1..16) | read-only | optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object | |
Failed - NoSuchName |
| 2 - Set Object to Min. Value | |
Failed - NoSuchName |
| 3 - Set Object to Max. Value | |
Failed - NoSuchName |
| 5 - Attempt Read of Non-Accessible Object | |
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. | |
Skipped - not writable |
| 7 - Attempt to Set Value < Min. | |
Skipped - not writable |
| 8 - Restore Object to Original Value | |
Skipped - Not writable |
Overall Test Case Results: Passed
Object Test Case TC-O-332
VDOT Implemented: Yes
| Std Par Ref | 5.11.2.6.3.2 |
| OID | 1.3.6.1.4.1.1206.4.2.3.9.7.27.1.2.1 |
| Object Name | dmsDrumDescription |
| Syntax | Access | Status |
| DisplayString | read-only | optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object |
00 | Failed - NoSuchName |
| 2 - Set Object to Min. Value |
00 | Failed - NoSuchName |
| 3 - Set Object to Max. Value |
00 | Failed - NoSuchName |
| 4 - Attempt Write to Read-Only Object |
00 | Failed - NoSuchName |
| 5 - Attempt Read of Non-Accessible Object |
00 | Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
00 | Skipped - not writable |
| 7 - Attempt to Set Value < Min. |
00 | Skipped - not writable |
| 8 - Restore Object to Original Value |
00 | Skipped - Not writable |
Overall Test Case Results: Passed
Object Test Case TC-O-333
VDOT Implemented: Yes
| Std Par Ref | 5.11.2.6.3.3 |
| OID | 1.3.6.1.4.1.1206.4.2.3.9.7.27.1.3.1 |
| Object Name | dmsDrumMfrStatus |
| Syntax | Access | Status |
| DisplayString (SIZE (0..64)) | read-only | optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object |
00 | Failed - NoSuchName |
| 2 - Set Object to Min. Value |
00 | Failed - NoSuchName |
| 3 - Set Object to Max. Value |
00 | Failed - NoSuchName |
| 4 - Attempt Write to Read-Only Object |
00 | Failed - NoSuchName |
| 5 - Attempt Read of Non-Accessible Object |
00 | Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
00 | Skipped - not writable |
| 7 - Attempt to Set Value < Min. |
00 | Skipped - not writable |
| 8 - Restore Object to Original Value |
00 | Skipped - Not writable |
Overall Test Case Results: Passed
Object Test Case TC-O-334
VDOT Implemented: Yes
| Std Par Ref | 5.11.2.6.3.4 |
| OID | 1.3.6.1.4.1.1206.4.2.3.9.7.27.1.4.1 |
| Object Name | dmsDrumStatus |
| Syntax | Access | Status |
| INTEGER {enumeration} | read-only | optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object | |
Failed - NoSuchName |
| 2 - Set Object to Min. Value | |
Failed - NoSuchName |
| 3 - Set Object to Max. Value | |
Failed - NoSuchName |
| 5 - Attempt Read of Non-Accessible Object | |
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. | |
Skipped - not writable |
| 7 - Attempt to Set Value < Min. | |
Skipped - not writable |
| 8 - Restore Object to Original Value | |
Skipped - Not writable |
Overall Test Case Results: Passed
Object Test Case TC-O-335
VDOT Implemented: Yes
| Std Par Ref | 5.11.2.7.1 |
| OID | 1.3.6.1.4.1.1206.4.2.3.9.7.28.0 |
| Object Name | dmsLightSensorStatusMap |
| Syntax | Access | Status |
| OCTET STRING (SIZE (0..2)) | read-only | optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object |
07 | Success |
| 2 - Set Object to Min. Value |
07 | Success |
| 3 - Set Object to Max. Value |
07 | Success |
| 4 - Attempt Write to Read-Only Object |
00 | Failed - NoSuchName |
| 5 - Attempt Read of Non-Accessible Object |
00 | Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
00 | Skipped - not writable |
| 7 - Attempt to Set Value < Min. |
00 | Skipped - not writable |
| 8 - Restore Object to Original Value |
00 | Skipped - Not writable |
Overall Test Case Results: Passed
Object Test Case TC-O-336
VDOT Implemented: Yes
| Std Par Ref | 5.11.2.7.2 |
| OID | 1.3.6.1.4.1.1206.4.2.3.9.7.29.0 |
| Object Name | dmsLightSensorNumRows |
| Syntax | Access | Status |
| INTEGER (0..16) | read-only | optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object | 3 | Success |
| 2 - Set Object to Min. Value | 3 | Success |
| 3 - Set Object to Max. Value | 3 | Success |
| 4 - Attempt Write to Read-Only Object | |
Failed - NoSuchName |
| 5 - Attempt Read of Non-Accessible Object | |
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. | |
Skipped - not writable |
| 7 - Attempt to Set Value < Min. | |
Skipped - not writable |
| 8 - Restore Object to Original Value | |
Skipped - Not writable |
Overall Test Case Results: Passed
Object Test Case TC-O-337
VDOT Implemented: Yes
| Std Par Ref | 5.11.2.7.3.1 |
| OID | 1.3.6.1.4.1.1206.4.2.3.9.7.30.1.1.1 |
| Object Name | dmsLightSensorIndex |
| Syntax | Access | Status |
| INTEGER (1..16) | read-only | optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object | 1 | Success |
| 2 - Set Object to Min. Value | 1 | Success |
| 3 - Set Object to Max. Value | 1 | Success |
| 4 - Attempt Write to Read-Only Object | |
Failed - NoSuchName |
| 5 - Attempt Read of Non-Accessible Object | |
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. | |
Skipped - not writable |
| 7 - Attempt to Set Value < Min. | |
Skipped - not writable |
| 8 - Restore Object to Original Value | |
Skipped - Not writable |
Overall Test Case Results: Passed
Object Test Case TC-O-338
VDOT Implemented: Yes
| Std Par Ref | 5.11.2.7.3.2 |
| OID | 1.3.6.1.4.1.1206.4.2.3.9.7.30.1.2.1 |
| Object Name | dmsLightSensorDescription |
| Syntax | Access | Status |
| DisplayString | read-only | optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object | 50 68 6F 74 6F 63 65 6C 6C 00 00 00 00 00 00 00 00 00 00 00 | Success |
| 2 - Set Object to Min. Value | 50 68 6F 74 6F 63 65 6C 6C 00 00 00 00 00 00 00 00 00 00 00
| Success |
| 3 - Set Object to Max. Value | 50 68 6F 74 6F 63 65 6C 6C 00 00 00 00 00 00 00 00 00 00 00 | Success |
| 4 - Attempt Write to Read-Only Object |
00 | Failed - NoSuchName |
| 5 - Attempt Read of Non-Accessible Object |
00 | Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
00 | Skipped - not writable |
| 7 - Attempt to Set Value < Min. |
00 | Skipped - not writable |
| 8 - Restore Object to Original Value |
00 | Skipped - Not writable |
Overall Test Case Results: Passed
Object Test Case TC-O-339
VDOT Implemented: Yes
| Std Par Ref | 5.11.2.7.3.3 |
| OID | 1.3.6.1.4.1.1206.4.2.3.9.7.30.1.3.1 |
| Object Name | dmsLightSensorCurrentReading |
| Syntax | Access | Status |
| INTEGER (0..65535) | read-only | optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object | 0 | Success |
| 2 - Set Object to Min. Value | 0 | Success |
| 3 - Set Object to Max. Value | 0 | Success |
| 4 - Attempt Write to Read-Only Object | |
Failed - NoSuchName |
| 5 - Attempt Read of Non-Accessible Object | |
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. | |
Skipped - not writable |
| 7 - Attempt to Set Value < Min. | |
Skipped - not writable |
| 8 - Restore Object to Original Value | |
Skipped - Not writable |
Overall Test Case Results: Passed
Object Test Case TC-O-340
VDOT Implemented: Yes
| Std Par Ref | 5.11.2.7.3.4 |
| OID | 1.3.6.1.4.1.1206.4.2.3.9.7.30.1.4.1 |
| Object Name | dmsLightSensorStatus |
| Syntax | Access | Status |
| INTEGER {enumeration} | read-only | optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object | 3 (fail) | Success |
| 2 - Set Object to Min. Value | 3 (fail) | Success |
| 3 - Set Object to Max. Value | 3 (fail) | Success |
| 4 - Attempt Write to Read-Only Object | |
Failed - NoSuchName |
| 5 - Attempt Read of Non-Accessible Object | |
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. | |
Skipped - not writable |
| 7 - Attempt to Set Value < Min. | |
Skipped - not writable |
| 8 - Restore Object to Original Value | |
Skipped - Not writable |
Overall Test Case Results: Passed
Object Test Case TC-O-341
VDOT Implemented: Yes
| Std Par Ref | 5.11.2.8.1 |
| OID | 1.3.6.1.4.1.1206.4.2.3.9.7.31.0 |
| Object Name | dmsHumiditySensorStatusMap |
| Syntax | Access | Status |
| OCTET STRING (SIZE (0..2)) | read-only | optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object |
00 | Success |
| 2 - Set Object to Min. Value |
00 | Success |
| 3 - Set Object to Max. Value |
00 | Success |
| 4 - Attempt Write to Read-Only Object |
00 | Failed - NoSuchName |
| 5 - Attempt Read of Non-Accessible Object |
00 | Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
00 | Skipped - not writable |
| 7 - Attempt to Set Value < Min. |
00 | Skipped - not writable |
| 8 - Restore Object to Original Value |
00 | Skipped - Not writable |
Overall Test Case Results: Passed
Object Test Case TC-O-342
VDOT Implemented: Yes
| Std Par Ref | 5.11.2.8.2 |
| OID | 1.3.6.1.4.1.1206.4.2.3.9.7.32.0 |
| Object Name | dmsHumiditySensorNumRows |
| Syntax | Access | Status |
| SEQUENCE OF DmsHumiditySensorStatusEntry | not-accessible | optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object | 0 | Success |
| 2 - Set Object to Min. Value | 0 | Success |
| 3 - Set Object to Max. Value | 0 | Success |
| 4 - Attempt Write to Read-Only Object | |
Failed - NoSuchName |
| 5 - Attempt Read of Non-Accessible Object | |
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. | |
Skipped - not writable |
| 7 - Attempt to Set Value < Min. | |
Skipped - not writable |
| 8 - Restore Object to Original Value | |
Skipped - Not writable |
Overall Test Case Results: Passed
Object Test Case TC-O-343
VDOT Implemented: Yes
| Std Par Ref | 5.11.2.8.2.1 |
| OID | 1.3.6.1.4.1.1206.4.2.3.9.7.33.1.1.1 |
| Object Name | dmsHumiditySensorIndex |
| Syntax | Access | Status |
| INTEGER (1..16) | read-only | optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object | |
Failed - GenErr |
| 2 - Set Object to Min. Value | |
Failed - GenErr |
| 3 - Set Object to Max. Value | |
Failed - GenErr |
| 5 - Attempt Read of Non-Accessible Object | |
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. | |
Skipped - not writable |
| 7 - Attempt to Set Value < Min. | |
Skipped - not writable |
| 8 - Restore Object to Original Value | |
Skipped - Not writable |
Overall Test Case Results: Passed
Object Test Case TC-O-344
VDOT Implemented: Yes
| Std Par Ref | 5.11.2.8.2.2 |
| OID | 1.3.6.1.4.1.1206.4.2.3.9.7.33.1.2.1 |
| Object Name | dmsHumiditySensorDescription |
| Syntax | Access | Status |
| DisplayString | read-only | optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object |
00 | Failed - GenErr |
| 2 - Set Object to Min. Value |
00 | Failed - GenErr |
| 3 - Set Object to Max. Value |
00 | Failed - GenErr |
| 4 - Attempt Write to Read-Only Object |
00 | Failed - GenErr |
| 5 - Attempt Read of Non-Accessible Object |
00 | Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
00 | Skipped - not writable |
| 7 - Attempt to Set Value < Min. |
00 | Skipped - not writable |
| 8 - Restore Object to Original Value |
00 | Skipped - Not writable |
Overall Test Case Results: Passed
Object Test Case TC-O-345
VDOT Implemented: Yes
| Std Par Ref | 5.11.2.8.2.3 |
| OID | 1.3.6.1.4.1.1206.4.2.3.9.7.33.1.3.1 |
| Object Name | dmsHumiditySensorCurrentReading |
| Syntax | Access | Status |
| INTEGER (0..100) | read-only | optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object | |
Failed - GenErr |
| 2 - Set Object to Min. Value | |
Failed - GenErr |
| 3 - Set Object to Max. Value | |
Failed - GenErr |
| 5 - Attempt Read of Non-Accessible Object | |
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. | |
Skipped - not writable |
| 7 - Attempt to Set Value < Min. | |
Skipped - not writable |
| 8 - Restore Object to Original Value | |
Skipped - Not writable |
Overall Test Case Results: Passed
Object Test Case TC-O-346
VDOT Implemented: Yes
| Std Par Ref | 5.11.2.8.2.4 |
| OID | 1.3.6.1.4.1.1206.4.2.3.9.7.33.1.4.1 |
| Object Name | dmsHumiditySensorStatus |
| Syntax | Access | Status |
| INTEGER {enumeration} | read-only | optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object | |
Failed - GenErr |
| 2 - Set Object to Min. Value | |
Failed - GenErr |
| 3 - Set Object to Max. Value | |
Failed - GenErr |
| 5 - Attempt Read of Non-Accessible Object | |
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. | |
Skipped - not writable |
| 7 - Attempt to Set Value < Min. | |
Skipped - not writable |
| 8 - Restore Object to Original Value | |
Skipped - Not writable |
Overall Test Case Results: Passed
Object Test Case TC-O-347
VDOT Implemented: Yes
| Std Par Ref | 5.11.2.9.1 |
| OID | 1.3.6.1.4.1.1206.4.2.3.9.7.34.0 |
| Object Name | dmsTempSensorStatusMap |
| Syntax | Access | Status |
| OCTET STRING (SIZE (0..2)) | read-only | optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object |
01 | Success |
| 2 - Set Object to Min. Value |
01 | Success |
| 3 - Set Object to Max. Value |
01 | Success |
| 4 - Attempt Write to Read-Only Object |
00 | Failed - NoSuchName |
| 5 - Attempt Read of Non-Accessible Object |
00 | Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
00 | Skipped - not writable |
| 7 - Attempt to Set Value < Min. |
00 | Skipped - not writable |
| 8 - Restore Object to Original Value |
00 | Skipped - Not writable |
Overall Test Case Results: Passed
Object Test Case TC-O-348
VDOT Implemented: Yes
| Std Par Ref | 5.11.2.9.2 |
| OID | 1.3.6.1.4.1.1206.4.2.3.9.7.35.0 |
| Object Name | dmsTempSensorNumRows |
| Syntax | Access | Status |
| INTEGER (0..16) | read-only | optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object | 1 | Success |
| 2 - Set Object to Min. Value | 1 | Success |
| 3 - Set Object to Max. Value | 1 | Success |
| 4 - Attempt Write to Read-Only Object | |
Failed - NoSuchName |
| 5 - Attempt Read of Non-Accessible Object | |
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. | |
Skipped - not writable |
| 7 - Attempt to Set Value < Min. | |
Skipped - not writable |
| 8 - Restore Object to Original Value | |
Skipped - Not writable |
Overall Test Case Results: Passed
Object Test Case TC-O-349
VDOT Implemented: Yes
| Std Par Ref | 5.11.2.9.3.1 |
| OID | 1.3.6.1.4.1.1206.4.2.3.9.7.36.1.1.1 |
| Object Name | dmsTempSensorIndex |
| Syntax | Access | Status |
| INTEGER (1..16) | read-only | optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object | 1 | Success |
| 2 - Set Object to Min. Value | 1 | Success |
| 3 - Set Object to Max. Value | 1 | Success |
| 4 - Attempt Write to Read-Only Object | |
Failed - NoSuchName |
| 5 - Attempt Read of Non-Accessible Object | |
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. | |
Skipped - not writable |
| 7 - Attempt to Set Value < Min. | |
Skipped - not writable |
| 8 - Restore Object to Original Value | |
Skipped - Not writable |
Overall Test Case Results: Passed
Object Test Case TC-O-350
VDOT Implemented: Yes
| Std Par Ref | 5.11.2.9.3.2 |
| OID | 1.3.6.1.4.1.1206.4.2.3.9.7.36.1.2.1 |
| Object Name | dmsTempSensorDescription |
| Syntax | Access | Status |
| DisplayString | read-only | optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object | 54 65 6D 70 65 72 61 74 75 72 65 20 73 65 6E 73 6F 72 00 00 | Success |
| 2 - Set Object to Min. Value | 54 65 6D 70 65 72 61 74 75 72 65 20 73 65 6E 73 6F 72 00 00 | Success |
| 3 - Set Object to Max. Value | 54 65 6D 70 65 72 61 74 75 72 65 20 73 65 6E 73 6F 72 00 00 | Success |
| 4 - Attempt Write to Read-Only Object |
00 | Failed - NoSuchName |
| 5 - Attempt Read of Non-Accessible Object |
00 | Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
00 | Skipped - not writable |
| 7 - Attempt to Set Value < Min. |
00 | Skipped - not writable |
| 8 - Restore Object to Original Value |
00 | Skipped - Not writable |
Overall Test Case Results: Passed
Object Test Case TC-O-351
VDOT Implemented: Yes
| Std Par Ref | 5.11.2.9.3.3 |
| OID | 1.3.6.1.4.1.1206.4.2.3.9.7.36.1.3.1 |
| Object Name | dmsTempSensorCurrentReading |
| Syntax | Access | Status |
| INTEGER (-128..127) | read-only | optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object | 0 | Success |
| 2 - Set Object to Min. Value | 0 | Success |
| 3 - Set Object to Max. Value | 0 | Success |
| 4 - Attempt Write to Read-Only Object | |
Failed - NoSuchName |
| 5 - Attempt Read of Non-Accessible Object | |
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. | |
Skipped - not writable |
| 7 - Attempt to Set Value < Min. | |
Skipped - not writable |
| 8 - Restore Object to Original Value | |
Skipped - Not writable |
Overall Test Case Results: Passed
Object Test Case TC-O-352
VDOT Implemented: Yes
| Std Par Ref | 5.11.2.9.3.4 |
| OID | 1.3.6.1.4.1.1206.4.2.3.9.7.36.1.4.1 |
| Object Name | dmsTempSensorHighWarningTem |
| Syntax | Access | Status |
| INTEGER (-128..127) | read-only | optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object | 55 | Success |
| 2 - Set Object to Min. Value | 55 | Success |
| 3 - Set Object to Max. Value | 55 | Success |
| 4 - Attempt Write to Read-Only Object | |
Failed - NoSuchName |
| 5 - Attempt Read of Non-Accessible Object | |
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. | |
Skipped - not writable |
| 7 - Attempt to Set Value < Min. | |
Skipped - not writable |
| 8 - Restore Object to Original Value | |
Skipped - Not writable |
Overall Test Case Results: Passed
Object Test Case TC-O-353
VDOT Implemented: Yes
| Std Par Ref | 5.11.2.9.3.5 |
| OID | 1.3.6.1.4.1.1206.4.2.3.9.7.36.1.5.1 |
| Object Name | dmsTempSensorLowWarningTemp |
| Syntax | Access | Status |
| INTEGER (-128..127) | read-only | optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object | -128 | Success |
| 2 - Set Object to Min. Value | -128 | Success |
| 3 - Set Object to Max. Value | -128 | Success |
| 4 - Attempt Write to Read-Only Object | |
Failed - NoSuchName |
| 5 - Attempt Read of Non-Accessible Object | |
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. | |
Skipped - not writable |
| 7 - Attempt to Set Value < Min. | |
Skipped - not writable |
| 8 - Restore Object to Original Value | |
Skipped - Not writable |
Overall Test Case Results: Passed
Object Test Case TC-O-354
VDOT Implemented: Yes
| Std Par Ref | 5.11.2.9.3.6 |
| OID | 1.3.6.1.4.1.1206.4.2.3.9.7.36.1.6.1 |
| Object Name | dmsTempSensorHighCriticalTemp |
| Syntax | Access | Status |
| INTEGER (-128..127) | read-only | optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object | 60 | Success |
| 2 - Set Object to Min. Value | 60 | Success |
| 3 - Set Object to Max. Value | 60 | Success |
| 4 - Attempt Write to Read-Only Object | |
Failed - NoSuchName |
| 5 - Attempt Read of Non-Accessible Object | |
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. | |
Skipped - not writable |
| 7 - Attempt to Set Value < Min. | |
Skipped - not writable |
| 8 - Restore Object to Original Value | |
Skipped - Not writable |
Overall Test Case Results: Passed
Object Test Case TC-O-355
VDOT Implemented: Yes
| Std Par Ref | 5.11.2.9.3.7 |
| OID | 1.3.6.1.4.1.1206.4.2.3.9.7.36.1.7.1 |
| Object Name | dmsTempSensorLowCriticalTempe |
| Syntax | Access | Status |
| INTEGER (-128..127) | read-only | optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object | -128 | Success |
| 2 - Set Object to Min. Value | -128 | Success |
| 3 - Set Object to Max. Value | -128 | Success |
| 4 - Attempt Write to Read-Only Object | |
Failed - NoSuchName |
| 5 - Attempt Read of Non-Accessible Object | |
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. | |
Skipped - not writable |
| 7 - Attempt to Set Value < Min. | |
Skipped - not writable |
| 8 - Restore Object to Original Value | |
Skipped - Not writable |
Overall Test Case Results: Passed
Object Test Case TC-O-356
VDOT Implemented: Yes
| Std Par Ref | 5.11.2.9.3.8 |
| OID | 1.3.6.1.4.1.1206.4.2.3.9.7.36.1.8.1 |
| Object Name | dmsTempSensorStatus |
| Syntax | Access | Status |
| INTEGER {enumeration} | read-only | optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object | 3 (fail) | Success |
| 2 - Set Object to Min. Value | 3 (fail) | Success |
| 3 - Set Object to Max. Value | 3 (fail) | Success |
| 4 - Attempt Write to Read-Only Object | |
Failed - NoSuchName |
| 5 - Attempt Read of Non-Accessible Object | |
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. | |
Skipped - not writable |
| 7 - Attempt to Set Value < Min. | |
Skipped - not writable |
| 8 - Restore Object to Original Value | |
Skipped - Not writable |
Overall Test Case Results: Passed
Object Test Case TC-O-357
VDOT Implemented: Yes
| Std Par Ref | 5.11.3.1 |
| OID | 1.3.6.1.4.1.1206.4.2.3.9.8.1.0 |
| Object Name | signVolts |
| Syntax | Access | Status |
| INTEGER (0..65535) | read-only | deprectated |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object | |
Failed - NoSuchName |
| 2 - Set Object to Min. Value | |
Failed - NoSuchName |
| 3 - Set Object to Max. Value | |
Failed - NoSuchName |
| 5 - Attempt Read of Non-Accessible Object | |
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. | |
Skipped - not writable |
| 7 - Attempt to Set Value < Min. | |
Skipped - not writable |
| 8 - Restore Object to Original Value | |
Skipped - Not writable |
Overall Test Case Results: Passed
Object Test Case TC-O-358
VDOT Implemented: Yes
| Std Par Ref | 5.11.3.2 |
| OID | 1.3.6.1.4.1.1206.4.2.3.9.8.2.0 |
| Object Name | lowFuelThreshold |
| Syntax | Access | Status |
| INTEGER (0..100) | read-write | deprectated |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object | |
Failed - NoSuchName |
| 2 - Set Object to Min. Value | |
Failed - NoSuchName |
| 3 - Set Object to Max. Value | |
Failed - NoSuchName |
| 4 - Attempt Write to Read-Only Object | |
Skipped - Not read only |
| 5 - Attempt Read of Non-Accessible Object | |
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. | 101 | Success - did not write greater than Max |
| 7 - Attempt to Set Value < Min. | -1 | Success - did not write less than Min |
Overall Test Case Results: Passed
Object Test Case TC-O-359
VDOT Implemented: Yes
| Std Par Ref | 5.11.3.3 |
| OID | 1.3.6.1.4.1.1206.4.2.3.9.8.3.0 |
| Object Name | fuelLevel |
| Syntax | Access | Status |
| INTEGER (0..100) | read-only | deprectated |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object | |
Failed - NoSuchName |
| 2 - Set Object to Min. Value | |
Failed - NoSuchName |
| 3 - Set Object to Max. Value | |
Failed - NoSuchName |
| 5 - Attempt Read of Non-Accessible Object | |
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. | |
Skipped - not writable |
| 7 - Attempt to Set Value < Min. | |
Skipped - not writable |
| 8 - Restore Object to Original Value | |
Skipped - Not writable |
Overall Test Case Results: Passed
Object Test Case TC-O-360
VDOT Implemented: Yes
| Std Par Ref | 5.11.3.4 |
| OID | 1.3.6.1.4.1.1206.4.2.3.9.8.4.0 |
| Object Name | engineRPM |
| Syntax | Access | Status |
| INTEGER (0..255) | read-only | deprectated |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object | |
Failed - NoSuchName |
| 2 - Set Object to Min. Value | |
Failed - NoSuchName |
| 3 - Set Object to Max. Value | |
Failed - NoSuchName |
| 5 - Attempt Read of Non-Accessible Object | |
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. | |
Skipped - not writable |
| 7 - Attempt to Set Value < Min. | |
Skipped - not writable |
| 8 - Restore Object to Original Value | |
Skipped - Not writable |
Overall Test Case Results: Passed
Object Test Case TC-O-361
VDOT Implemented: Yes
| Std Par Ref | 5.11.3.5 |
| OID | 1.3.6.1.4.1.1206.4.2.3.9.8.5.0 |
| Object Name | lineVolts |
| Syntax | Access | Status |
| INTEGER (0..255) | read-only | deprectated |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object | |
Failed - NoSuchName |
| 2 - Set Object to Min. Value | |
Failed - NoSuchName |
| 3 - Set Object to Max. Value | |
Failed - NoSuchName |
| 5 - Attempt Read of Non-Accessible Object | |
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. | |
Skipped - not writable |
| 7 - Attempt to Set Value < Min. | |
Skipped - not writable |
| 8 - Restore Object to Original Value | |
Skipped - Not writable |
Overall Test Case Results: Passed
Object Test Case TC-O-362
VDOT Implemented: Yes
| Std Par Ref | 5.11.3.6 |
| OID | 1.3.6.1.4.1.1206.4.2.3.9.8.6.0 |
| Object Name | powerSource |
| Syntax | Access | Status |
| INTEGER {enumeration} | read-only | optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object | 4 (acLine) | Success |
| 2 - Set Object to Min. Value | 4 (acLine) | Success |
| 3 - Set Object to Max. Value | 4 (acLine) | Success |
| 4 - Attempt Write to Read-Only Object | |
Failed - NoSuchName |
| 5 - Attempt Read of Non-Accessible Object | |
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. | |
Skipped - not writable |
| 7 - Attempt to Set Value < Min. | |
Skipped - not writable |
| 8 - Restore Object to Original Value | |
Skipped - Not writable |
Overall Test Case Results: Passed
Object Test Case TC-O-363
VDOT Implemented: Yes
| Std Par Ref | 5.11.4.1 |
| OID | 1.3.6.1.4.1.1206.4.2.3.9.9.1.0 |
| Object Name | tempMinCtrlCabinet |
| Syntax | Access | Status |
| INTEGER (-128..127) | read-only | optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object | 34 | Success |
| 2 - Set Object to Min. Value | 34 | Success |
| 3 - Set Object to Max. Value | 34 | Success |
| 4 - Attempt Write to Read-Only Object | |
Failed - NoSuchName |
| 5 - Attempt Read of Non-Accessible Object | |
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. | |
Skipped - not writable |
| 7 - Attempt to Set Value < Min. | |
Skipped - not writable |
| 8 - Restore Object to Original Value | |
Skipped - Not writable |
Overall Test Case Results: Passed
Object Test Case TC-O-364
VDOT Implemented: Yes
| Std Par Ref | 5.11.4.2 |
| OID | 1.3.6.1.4.1.1206.4.2.3.9.9.2.0 |
| Object Name | tempMaxCtrlCabinet |
| Syntax | Access | Status |
| INTEGER (-128..127) | read-only | optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object | 34 | Success |
| 2 - Set Object to Min. Value | 34 | Success |
| 3 - Set Object to Max. Value | 34 | Success |
| 4 - Attempt Write to Read-Only Object | |
Failed - NoSuchName |
| 5 - Attempt Read of Non-Accessible Object | |
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. | |
Skipped - not writable |
| 7 - Attempt to Set Value < Min. | |
Skipped - not writable |
| 8 - Restore Object to Original Value | |
Skipped - Not writable |
Overall Test Case Results: Passed
Object Test Case TC-O-365
VDOT Implemented: Yes
| Std Par Ref | 5.11.4.3 |
| OID | 1.3.6.1.4.1.1206.4.2.3.9.9.3.0 |
| Object Name | tempMinAmbient |
| Syntax | Access | Status |
| INTEGER (-128..127) | read-only | optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object | 0 | Success |
| 2 - Set Object to Min. Value | 0 | Success |
| 3 - Set Object to Max. Value | 0 | Success |
| 4 - Attempt Write to Read-Only Object | |
Failed - NoSuchName |
| 5 - Attempt Read of Non-Accessible Object | |
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. | |
Skipped - not writable |
| 7 - Attempt to Set Value < Min. | |
Skipped - not writable |
| 8 - Restore Object to Original Value | |
Skipped - Not writable |
Overall Test Case Results: Passed
Object Test Case TC-O-366
VDOT Implemented: Yes
| Std Par Ref | 5.11.4.4 |
| OID | 1.3.6.1.4.1.1206.4.2.3.9.9.4.0 |
| Object Name | tempMaxAmbient |
| Syntax | Access | Status |
| INTEGER (-128..127) | read-only | optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object | 0 | Success |
| 2 - Set Object to Min. Value | 0 | Success |
| 3 - Set Object to Max. Value | 0 | Success |
| 4 - Attempt Write to Read-Only Object | |
Failed - NoSuchName |
| 5 - Attempt Read of Non-Accessible Object | |
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. | |
Skipped - not writable |
| 7 - Attempt to Set Value < Min. | |
Skipped - not writable |
| 8 - Restore Object to Original Value | |
Skipped - Not writable |
Overall Test Case Results: Passed
Object Test Case TC-O-367
VDOT Implemented: Yes
| Std Par Ref | 5.11.4.5 |
| OID | 1.3.6.1.4.1.1206.4.2.3.9.9.5.0 |
| Object Name | tempMinSignHousing |
| Syntax | Access | Status |
| INTEGER (-128..127) | read-only | optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object | 0 | Success |
| 2 - Set Object to Min. Value | 0 | Success |
| 3 - Set Object to Max. Value | 0 | Success |
| 4 - Attempt Write to Read-Only Object | |
Failed - NoSuchName |
| 5 - Attempt Read of Non-Accessible Object | |
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. | |
Skipped - not writable |
| 7 - Attempt to Set Value < Min. | |
Skipped - not writable |
| 8 - Restore Object to Original Value | |
Skipped - Not writable |
Overall Test Case Results: Passed
Object Test Case TC-O-368
VDOT Implemented: Yes
| Std Par Ref | 5.11.4.6 |
| OID | 1.3.6.1.4.1.1206.4.2.3.9.9.6.0 |
| Object Name | tempMaxSignHousing |
| Syntax | Access | Status |
| INTEGER (-128..127) | read-only | optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object | 0 | Success |
| 2 - Set Object to Min. Value | 0 | Success |
| 3 - Set Object to Max. Value | 0 | Success |
| 4 - Attempt Write to Read-Only Object | |
Failed - NoSuchName |
| 5 - Attempt Read of Non-Accessible Object | |
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. | |
Skipped - not writable |
| 7 - Attempt to Set Value < Min. | |
Skipped - not writable |
| 8 - Restore Object to Original Value | |
Skipped - Not writable |
Overall Test Case Results: Passed
Object Test Case TC-O-369
VDOT Implemented: Yes
| Std Par Ref | 5.11.4.7 |
| OID | 1.3.6.1.4.1.1206.4.2.3.9.9.7.0 |
| Object Name | tempSensorWarningMap |
| Syntax | Access | Status |
| OCTET STRING (SIZE (0..2)) | read-only | optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object |
00 | Success |
| 2 - Set Object to Min. Value |
00 | Success |
| 3 - Set Object to Max. Value |
00 | Success |
| 4 - Attempt Write to Read-Only Object |
00 | Failed - NoSuchName |
| 5 - Attempt Read of Non-Accessible Object |
00 | Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
00 | Skipped - not writable |
| 7 - Attempt to Set Value < Min. |
00 | Skipped - not writable |
| 8 - Restore Object to Original Value |
00 | Skipped - Not writable |
Overall Test Case Results: Passed
Object Test Case TC-O-370
VDOT Implemented: Yes
| Std Par Ref | 5.11.4.8 |
| OID | 1.3.6.1.4.1.1206.4.2.3.9.9.8.0 |
| Object Name | tempSensorCriticalTempMap |
| Syntax | Access | Status |
| OCTET STRING (SIZE (0..2)) | read-only | optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object |
00 | Success |
| 2 - Set Object to Min. Value |
00 | Success |
| 3 - Set Object to Max. Value |
00 | Success |
| 4 - Attempt Write to Read-Only Object |
00 | Failed - NoSuchName |
| 5 - Attempt Read of Non-Accessible Object |
00 | Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
00 | Skipped - not writable |
| 7 - Attempt to Set Value < Min. |
00 | Skipped - not writable |
| 8 - Restore Object to Original Value |
00 | Skipped - Not writable |
Overall Test Case Results: Passed
Object Test Case TC-O-371
VDOT Implemented: Yes
| Std Par Ref | 5.12.1 |
| OID | 1.3.6.1.4.1.1206.4.2.3.10.1.0 |
| Object Name | dmsGraphicMaxEntries |
| Syntax | Access | Status |
| INTEGER (0..255) | read-only | optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object | 32 | Success |
| 2 - Set Object to Min. Value | 32 | Success |
| 3 - Set Object to Max. Value | 32 | Success |
| 4 - Attempt Write to Read-Only Object | |
Failed - NoSuchName |
| 5 - Attempt Read of Non-Accessible Object | |
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. | |
Skipped - not writable |
| 7 - Attempt to Set Value < Min. | |
Skipped - not writable |
| 8 - Restore Object to Original Value | |
Skipped - Not writable |
Overall Test Case Results: Passed
Object Test Case TC-O-372
VDOT Implemented: Yes
| Std Par Ref | 5.12.2 |
| OID | 1.3.6.1.4.1.1206.4.2.3.10.2.0 |
| Object Name | dmsGraphicNumEntries |
| Syntax | Access | Status |
| INTEGER (0..255) | read-only | optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object | 0 | Success |
| 2 - Set Object to Min. Value | 0 | Success |
| 3 - Set Object to Max. Value | 0 | Success |
| 4 - Attempt Write to Read-Only Object | |
Failed - NoSuchName |
| 5 - Attempt Read of Non-Accessible Object | |
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. | |
Skipped - not writable |
| 7 - Attempt to Set Value < Min. | |
Skipped - not writable |
| 8 - Restore Object to Original Value | |
Skipped - Not writable |
Overall Test Case Results: Passed
Object Test Case TC-O-373
VDOT Implemented: Yes
| Std Par Ref | 5.12.3 |
| OID | 1.3.6.1.4.1.1206.4.2.3.10.3.0 |
| Object Name | dmsGraphicVertSpacing |
| Syntax | Access | Status |
| INTEGER (0..255) | read-write | optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object | 0 | Success |
| 2 - Set Object to Min. Value | 0 | Success |
| 3 - Set Object to Max. Value | 255 | Success |
| 4 - Attempt Write to Read-Only Object | |
Skipped - Not read only |
| 5 - Attempt Read of Non-Accessible Object | |
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. | 256 | Success - did not write greater than Max |
| 7 - Attempt to Set Value < Min. | -1 | Failed - wrote less than Min |
| 8 - Restore Object to Original Value | 0 | Success |
Overall Test Case Results: Passed
Object Test Case TC-O-374
VDOT Implemented: Yes
| Std Par Ref | 5.12.4 |
| OID | 1.3.6.1.4.1.1206.4.2.3.10.4.0 |
| Object Name | dmsGraphicHorzSpacing |
| Syntax | Access | Status |
| INTEGER (0..255) | read-write | optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object | 0 | Success |
| 2 - Set Object to Min. Value | 0 | Success |
| 3 - Set Object to Max. Value | 255 | Success |
| 4 - Attempt Write to Read-Only Object | |
Skipped - Not read only |
| 5 - Attempt Read of Non-Accessible Object | |
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. | 256 | Success - did not write greater than Max |
| 7 - Attempt to Set Value < Min. | -1 | Failed - wrote less than Min |
| 8 - Restore Object to Original Value | 0 | Success |
Overall Test Case Results: Passed
Object Test Case TC-O-375
VDOT Implemented: Yes
| Std Par Ref | 5.12.5 |
| OID | 1.3.6.1.4.1.1206.4.2.3.10.5.0 |
| Object Name | dmsGraphicMaxSize |
| Syntax | Access | Status |
| INTEGER (0..65535) | read-only | optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object | 203 | Success |
| 2 - Set Object to Min. Value | 203 | Success |
| 3 - Set Object to Max. Value | 203 | Success |
| 4 - Attempt Write to Read-Only Object | |
Failed - NoSuchName |
| 5 - Attempt Read of Non-Accessible Object | |
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. | |
Skipped - not writable |
| 7 - Attempt to Set Value < Min. | |
Skipped - not writable |
| 8 - Restore Object to Original Value | |
Skipped - Not writable |
Overall Test Case Results: Passed
Object Test Case TC-O-376
VDOT Implemented: Yes
| Std Par Ref | 5.12.6 |
| OID | 1.3.6.1.4.1.1206.4.2.3.10.6.0 |
| Object Name | availableGraphicMemory |
| Syntax | Access | Status |
| Counter | read-only | optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object | 6496 | Success |
| 2 - Set Object to Min. Value | 6496 | Success |
| 3 - Set Object to Max. Value | 6496 | Success |
| 4 - Attempt Write to Read-Only Object | |
Failed - NoSuchName |
| 5 - Attempt Read of Non-Accessible Object | |
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. | |
Skipped - not writable |
| 7 - Attempt to Set Value < Min. | |
Skipped - not writable |
| 8 - Restore Object to Original Value | |
Skipped - Not writable |
Overall Test Case Results: Passed
Object Test Case TC-O-377
VDOT Implemented: Yes
| Std Par Ref | 5.12.7 |
| OID | 1.3.6.1.4.1.1206.4.2.3.10.7.0 |
| Object Name | dmsGraphicBlockSize |
| Syntax | Access | Status |
| INTEGER (0..65535) | read-only | optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object | 203 | Success |
| 2 - Set Object to Min. Value | 203 | Success |
| 3 - Set Object to Max. Value | 203 | Success |
| 4 - Attempt Write to Read-Only Object | |
Failed - NoSuchName |
| 5 - Attempt Read of Non-Accessible Object | |
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. | |
Skipped - not writable |
| 7 - Attempt to Set Value < Min. | |
Skipped - not writable |
| 8 - Restore Object to Original Value | |
Skipped - Not writable |
Overall Test Case Results: Passed
Object Test Case TC-O-378
VDOT Implemented: Yes
| Std Par Ref | 5.12.8.1 |
| OID | 1.3.6.1.4.1.1206.4.2.3.10.8.1.1.1 |
| Object Name | dmsGraphicIndex |
| Syntax | Access | Status |
| INTEGER (1..255) | read-only | optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object | 1 | Success |
| 2 - Set Object to Min. Value | 1 | Success |
| 3 - Set Object to Max. Value | 1 | Success |
| 4 - Attempt Write to Read-Only Object | |
Failed - NoSuchName |
| 5 - Attempt Read of Non-Accessible Object | |
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. | |
Skipped - not writable |
| 7 - Attempt to Set Value < Min. | |
Skipped - not writable |
| 8 - Restore Object to Original Value | |
Skipped - Not writable |
Overall Test Case Results: Passed
Object Test Case TC-O-379
VDOT Implemented: Yes
| Std Par Ref | 5.12.8.2 |
| OID | 1.3.6.1.4.1.1206.4.2.3.10.8.1.2.1 |
| Object Name | dmsGraphicNumber |
| Syntax | Access | Status |
| INTEGER (1..255) | read-write | optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object | 0 | Success |
| 2 - Set Object to Min. Value | 0 | Success |
| 3 - Set Object to Max. Value | 0 | Success |
| 4 - Attempt Write to Read-Only Object | |
Skipped - Not read only |
| 5 - Attempt Read of Non-Accessible Object | |
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. | 256 | Success - did not write greater than Max |
| 7 - Attempt to Set Value < Min. | 0 | Success - did not write less than Min |
| 8 - Restore Object to Original Value | |
Failed - BadValue |
Overall Test Case Results: Passed
Object Test Case TC-O-380
VDOT Implemented: Yes
| Std Par Ref | 5.12.8.3 |
| OID | 1.3.6.1.4.1.1206.4.2.3.10.8.1.3.1 |
| Object Name | dmsGraphicName |
| Syntax | Access | Status |
| DisplayString (SIZE (0..64)) | read-write | optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object | |
Success |
| 2 - Set Object to Min. Value | |
Success |
| 3 - Set Object to Max. Value | |
Success |
| 4 - Attempt Write to Read-Only Object |
00 | Skipped - Not read only |
| 5 - Attempt Read of Non-Accessible Object |
00 | Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. | 1 | Success - did not write greater than Max |
| 7 - Attempt to Set Value < Min. | -1 | Success - did not write less than Min |
| 8 - Restore Object to Original Value |
00 | Failed - GenErr |
Overall Test Case Results: Passed
Object Test Case TC-O-381
VDOT Implemented: Yes
| Std Par Ref | 5.12.8.4 |
| OID | 1.3.6.1.4.1.1206.4.2.3.10.8.1.4.1 |
| Object Name | dmsGraphicHeight |
| Syntax | Access | Status |
| INTEGER (1..255) | read-write | optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object | 0 | Success |
| 2 - Set Object to Min. Value | 0 | Success |
| 3 - Set Object to Max. Value | 0 | Success |
| 4 - Attempt Write to Read-Only Object | |
Skipped - Not read only |
| 5 - Attempt Read of Non-Accessible Object | |
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. | 256 | Success - did not write greater than Max |
| 7 - Attempt to Set Value < Min. | 0 | Success - did not write less than Min |
| 8 - Restore Object to Original Value | |
Failed - GenErr |
Overall Test Case Results: Passed
Object Test Case TC-O-382
VDOT Implemented: Yes
| Std Par Ref | 5.12.8.5 |
| OID | 1.3.6.1.4.1.1206.4.2.3.10.8.1.5.1 |
| Object Name | dmsGraphicWidth |
| Syntax | Access | Status |
| INTEGER (1..65535) | read-write | optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object | 0 | Success |
| 2 - Set Object to Min. Value | 0 | Success |
| 3 - Set Object to Max. Value | 0 | Success |
| 4 - Attempt Write to Read-Only Object | |
Skipped - Not read only |
| 5 - Attempt Read of Non-Accessible Object | |
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. | 65536 | Success - did not write greater than Max |
| 7 - Attempt to Set Value < Min. | 0 | Success - did not write less than Min |
| 8 - Restore Object to Original Value | |
Failed - BadValue |
Overall Test Case Results: Passed
Object Test Case TC-O-383
VDOT Implemented: Yes
| Std Par Ref | 5.12.8.6 |
| OID | 1.3.6.1.4.1.1206.4.2.3.10.8.1.6.1 |
| Object Name | dmsGraphicType |
| Syntax | Access | Status |
| INTEGER {enumeration} | read-write | optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object | 0 | Success |
| 2 - Set Object to Min. Value | 0 | Success |
| 3 - Set Object to Max. Value | 0 | Success |
| 4 - Attempt Write to Read-Only Object | |
Skipped - Not read only |
| 5 - Attempt Read of Non-Accessible Object | |
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. | |
Skipped - no Minimum |
| 7 - Attempt to Set Value < Min. | |
Skipped - no Minimum |
| 8 - Restore Object to Original Value | |
Failed - BadValue |
Overall Test Case Results: Passed
Object Test Case TC-O-384
VDOT Implemented: Yes
| Std Par Ref | 5.12.8.7 |
| OID | 1.3.6.1.4.1.1206.4.2.3.10.8.1.7.1 |
| Object Name | dmsGraphicID |
| Syntax | Access | Status |
| INTEGER (0..65535) | read-only | optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object | 0 | Success |
| 2 - Set Object to Min. Value | 0 | Success |
| 3 - Set Object to Max. Value | 0 | Success |
| 4 - Attempt Write to Read-Only Object | |
Failed - NoSuchName |
| 5 - Attempt Read of Non-Accessible Object | |
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. | |
Skipped - not writable |
| 7 - Attempt to Set Value < Min. | |
Skipped - not writable |
| 8 - Restore Object to Original Value | |
Skipped - Not writable |
Overall Test Case Results: Passed
Object Test Case TC-O-385
VDOT Implemented: Yes
| Std Par Ref | 5.12.8.8 |
| OID | 1.3.6.1.4.1.1206.4.2.3.10.8.1.8.1 |
| Object Name | dmsGraphicTransparentEnabled |
| Syntax | Access | Status |
| INTEGER (0..1) | read-write | optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object | 0 | Success |
| 2 - Set Object to Min. Value | 0 | Success |
| 3 - Set Object to Max. Value | 0 | Success |
| 4 - Attempt Write to Read-Only Object | |
Skipped - Not read only |
| 5 - Attempt Read of Non-Accessible Object | |
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. | 2 | Success - did not write greater than Max |
| 7 - Attempt to Set Value < Min. | -1 | Success - did not write less than Min |
| 8 - Restore Object to Original Value | |
Failed - GenErr |
Overall Test Case Results: Passed
Object Test Case TC-O-386
VDOT Implemented: Yes
| Std Par Ref | 5.12.8.9 |
| OID | 1.3.6.1.4.1.1206.4.2.3.10.8.1.9.1 |
| Object Name | dmsGraphicTransparentColor |
| Syntax | Access | Status |
| OCTET STRING (SIZE(1 | 3)) | read-write | optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object |
00 | Success |
| 2 - Set Object to Min. Value |
00 | Success |
| 3 - Set Object to Max. Value |
00 | Success |
| 4 - Attempt Write to Read-Only Object |
00 | Skipped - Not read only |
| 5 - Attempt Read of Non-Accessible Object |
00 | Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. | 1 | Success - did not write greater than Max |
| 7 - Attempt to Set Value < Min. | -1 | Success - did not write less than Min |
| 8 - Restore Object to Original Value |
00 | Failed - GenErr |
Overall Test Case Results: Passed
Object Test Case TC-O-387
VDOT Implemented: Yes
| Std Par Ref | 5.12.8.10 |
| OID | 1.3.6.1.4.1.1206.4.2.3.10.8.1.10.1 |
| Object Name | dmsGraphicStatus |
| Syntax | Access | Status |
| INTEGER {enumeration} | read-write | optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object | 1 (notUsed) | Success |
| 2 - Set Object to Min. Value | 1 (notUsed) | Success |
| 3 - Set Object to Max. Value | 1 (notUsed) | Success |
| 4 - Attempt Write to Read-Only Object | |
Skipped - Not read only |
| 5 - Attempt Read of Non-Accessible Object | |
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. | |
Skipped - no Minimum |
| 7 - Attempt to Set Value < Min. | |
Skipped - no Minimum |
| 8 - Restore Object to Original Value | |
Failed - BadValue |
Overall Test Case Results: Passed
Object Test Case TC-O-388
VDOT Implemented: Yes
| Std Par Ref | 5.12.9.1 |
| OID | 1.3.6.1.4.1.1206.4.2.3.10.9.1.1.1.1 |
| Object Name | dmsGraphicBitmapIndex |
| Syntax | Access | Status |
| INTEGER (1..255) | read-only | optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object | 1 | Success |
| 2 - Set Object to Min. Value | 1 | Success |
| 3 - Set Object to Max. Value | 1 | Success |
| 4 - Attempt Write to Read-Only Object | |
Failed - NoSuchName |
| 5 - Attempt Read of Non-Accessible Object | |
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. | |
Skipped - not writable |
| 7 - Attempt to Set Value < Min. | |
Skipped - not writable |
| 8 - Restore Object to Original Value | |
Skipped - Not writable |
Overall Test Case Results: Passed
Object Test Case TC-O-389
VDOT Implemented: Yes
| Std Par Ref | 5.12.9.2 |
| OID | 1.3.6.1.4.1.1206.4.2.3.10.9.1.2.1.1 |
| Object Name | dmsGraphicBlockNumber |
| Syntax | Access | Status |
| INTEGER (1..255) | read-write | optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object | 0 | Success |
| 2 - Set Object to Min. Value | 0 | Success |
| 3 - Set Object to Max. Value | 0 | Success |
| 4 - Attempt Write to Read-Only Object | |
Skipped - Not read only |
| 5 - Attempt Read of Non-Accessible Object | |
Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. | 256 | Success - did not write greater than Max |
| 7 - Attempt to Set Value < Min. | 0 | Success - did not write less than Min |
| 8 - Restore Object to Original Value | |
Failed - NoSuchName |
Overall Test Case Results: Passed
Object Test Case TC-O-390
VDOT Implemented: Yes
| Std Par Ref | 5.12.9.3 |
| OID | 1.3.6.1.4.1.1206.4.2.3.10.9.1.3.1.1 |
| Object Name | dmsGraphicBlockBitmap |
| Syntax | Access | Status |
| OCTET STRING | read-write | optional |
| Test Type | Test Value | Test Results |
|---|
| 1 - Read Initial Value of Object | 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 ... | Success |
| 2 - Set Object to Min. Value | 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 ... | Success |
| 3 - Set Object to Max. Value | 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 ... | Success |
| 4 - Attempt Write to Read-Only Object |
00 | Skipped - Not read only |
| 5 - Attempt Read of Non-Accessible Object |
00 | Skipped - Not not-accessible |
| 6 - Attempt to Set Value > Max. |
00 | Skipped - no Minimum |
| 7 - Attempt to Set Value < Min. |
00 | Skipped - no Minimum |
| 8 - Restore Object to Original Value |
00 | Failed - GenErr |
Overall Test Case Results: Passed